Datasheet summary
SEA2-2540
Engineering summary from PDF text extraction for SEA2-2540. Verify every value with the OEM datasheet.
Summary
Product identification
This is a High Rejection, Excellent Productivity Sea Water Element, model SEA2-2540.
- Type: Spiral Wound
- Membrane Polymer: Composite Polyamide
- Brine Spacer Material: Polypropylene
Specifications
- Nominal Membrane Area: 28 ft² (2.6 m²)
Product water
- Permeate Flow: 650 gpd (2.5 m³/d)
- Salt Rejection: 99.4% nominal (99.2% minimum)
Test Conditions
(After 30 min of operation)
- Solution NaCl: 32000 ppm
- Applied Pressure: 800 psi (56 bar)
- Operating Temperature: 77 °F (25 °C)
- Permeate Recovery: 10%
- Permeate pH Range: 6.5 ÷ 7.0
Operating limits
- Operating Pressure: 1000 psi (69 bar)
- Temperature: 113 °F (45 °C)
- Pressure Drop: 10 psi (0.7 bar)
- Feed Flow: 6 gpm (23 lpm)
- Feedwater Chlorine Concentration: <0.1 ppm
- Feedwater SDI (15min): 5.0
- Feedwater Turbidity: 1.0 NTU
- Feedwater pH: 3.0 ÷ 10.0
- Minimum ratio of concentrate to permeate flow for any element: 5:1
Mechanical / hydraulic
- Total Length (A): 40.0 inches (1016 mm)
- Diameter (B): 2.4 inches (61 mm)
- Connection Diameter (C): 0.75 inches (19.1 mm)
- Core Tube Extension Feed Side (DF): 1.2 inches (30.5 mm)
- Core Tube Extension Concentrate Side (DC): 1.2 inches (30.5 mm)
- Weight: 4 lbs (1.8 Kg)
Important Notices and Guidelines
- Permeate flow for individual elements may vary ±20 percent.
- Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite.
- Permeate obtained from the first hour of operation should be discarded.
- Avoid static permeate-side backpressure at all times.
- These membranes may be subject to drinking water application restrictions in some countries; check the application status before use and sale.
- For element loading, use only glycerine to lubricate o-rings and brine seal.
- The presence of free chlorine and other oxidizing agents will cause membrane failure, and the damage is not covered under warranty.