Back to OLTREMARE
OLTREMARE logo

Datasheet summary

SEA2-4021

Engineering summary from PDF text extraction for SEA2-4021. Verify every value with the OEM datasheet.

Summary

Product Identification

  • Model: SEA2-4021
  • Type: High Rejection, Excellent Productivity - Sea Water Element
  • Configuration: Spiral Wound
  • Membrane Polymer: Composite Polyamide
  • Brine Spacer Material: Polypropylene

Specifications

  • Nominal Permeate Flow: 800 gpd (3 m³/d)
  • Nominal Salt Rejection: 99.4% nominal (99.2% minimum)
  • Nominal Membrane Area: 35 ft² (3.2 m²)

Standard Test Conditions

  • NaCl Solution: 32000 ppm
  • Applied Pressure: 800 psi (56 bar)
  • Operating Temperature: 77 °F (25 °C)
  • Permeate Recovery: 10%
  • pH (After 30 min of operation): 6.5 ÷ 7.0

Mechanical / Hydraulic

Dimensions

  • Total Length (A): 21.0 inches (533.4 mm)
  • ATD Diameter (B): 3.95 inches (100.3 mm)
  • Connection Diameter (C): 0.75 inches (19.1 mm)
  • Core Tube Extension Feed Side (DF): 1.2 inches (30.5 mm)
  • Core Tube Extension Conc. Side (DC): 1.2 inches (30.5 mm)
  • Weight: 4 lbs (1.8 Kg)

Maximum Operating Limits

  • Operating Pressure: 1000 psi (69 bar)
  • Temperature: 113 °F (45 °C)
  • Pressure Drop: 10 psi (0.7 bar)
  • Feed Flow: 12 gpm (45.4 lpm)
  • Chlorine Concentration: <0.1 ppm
  • Feedwater pH Range: 3.0 ÷ 10.0
  • Feedwater SDI (15min): 5.0
  • Feedwater Turbidity: 1.0 NTU
  • Minimum ratio of concentrate to permeate flow: 5:1

Operational Guidelines

  • Permeate flow for individual elements may vary + or -20 percent.
  • Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite.
  • Permeate obtained from the first hour of operation should be discarded.
  • Avoid static permeate-side backpressure at all times.
  • These membranes may be subject to drinking water application restrictions in some countries; please check the application status before use and sale.
  • For element loading, use only glycerine to lubricate o-rings and brine seal.
  • The presence of free chlorine and other oxidizing agents will cause membrane failure; the damage is not covered under warranty.

Disclaimer: This summary is based on the provided text extract. It may not include all figures, footnotes, or the latest revisions of the official PDF datasheet. For contractual purposes, always refer to the specific OEM PDF revision used for your project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.