Back to OLTREMARE
OLTREMARE logo

Datasheet summary

SEA5-2521

Engineering summary from PDF text extraction for SEA5-2521. Verify every value with the OEM datasheet.

Summary

Product Identification

  • Model: SEA5-2521
  • Type: Low Energy, Excellent Rejection, Very High Productivity - Sea Water Element

Specifications

  • Configuration: Spiral Wound
  • Membrane Polymer: Composite Polyamide
  • Brine Spacer Material: Polypropylene

Performance (Test Conditions)

  • Permeate Flow: 240 gpd (0.9 m³/d)
  • Salt Rejection: 99.6% nominal (99.4% minimum)
  • Nominal Membrane Area: 12 ft² (1.1 m²)

Test Conditions:

  • Solution: 32000 ppm NaCl
  • Applied Pressure: 800 psi (56 bar)
  • Operating Temperature: 77 °F (25 °C)
  • Permeate Recovery: 10%
  • pH Range (After 30 min of operation): 6.5 ÷ 7.0

Dimensions

  • Total Length (A): 21.0 inches (533.4 mm)
  • ATD Diameter (B): 2.4 inches (61 mm)
  • Connection Diameter (C): 0.75 inches (19.1 mm)
  • Core Tube Extension Feed Side (DF): 1.2 inches (30.5 mm)
  • Core Tube Extension Concentrate Side (DC): 1.2 inches (30.5 mm)
  • Weight: 2 lbs (0.9 Kg)

Operating Limits

  • Maximum Operating Pressure: 1000 psi (69 bar)
  • Maximum Temperature: 113 °F (45 °C)
  • Maximum Pressure Drop: 10 psi (0.7 bar)
  • Maximum Feed Flow: 6 gpm (23 lpm)
  • Maximum Feed Chlorine Concentration: <0.1 ppm
  • Feedwater pH: 3.0 ÷ 10.0
  • Maximum Feedwater SDI (15min): 5.0
  • Maximum Feedwater Turbidity: 1.0 NTU
  • Minimum ratio of concentrate to permeate flow for any element: 5:1

The limitations shown in Operating Limits are for general use. The values may be more conservative for specific projects to ensure the best performance and longest life of the membrane.

Important Notices and Guidelines

  • Permeate flow for individual elements may vary ±20 percent.
  • Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite.
  • Permeate obtained from the first hour of operation should be discarded.
  • Avoid static permeate-side backpressure at all times.
  • These membranes may be subject to drinking water application restrictions in some countries; check the application status before use and sale.
  • For element loading, use only glycerine to lubricate o-rings and brine seal.
  • The customer is fully responsible for the effects of incompatible chemicals on elements. The presence of free chlorine and other oxidizing agents will cause membrane failure; the damage is not covered under warranty.

Disclaimer: This summary is generated from extracted text and may not include all figures, footnotes, or the latest revisions present in the official PDF datasheet. For contractual data, always refer to the specific OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.