XL-1812
Engineering summary from PDF text extraction for XL-1812. Verify every value with the OEM datasheet.
Summary
Product identification
- Model: XL-1812
- Configuration: Spiral Wound
- Type: Low Energy, Brackish Water Element
- Membrane Polymer: Composite Polyamide
- Brine Spacer Material: Polypropylene
- Key Features: Excellent Productivity
Operating limits
- Maximum Operating Pressure: 125 psi (8.6 bar)
- Maximum Operating Temperature: 113 °F (45 °C)
- Maximum Feed Flow: 2 gpm (7.5 lpm)
- Maximum Pressure Drop: 10 psi (0.7 bar)
- Maximum Chlorine Concentration: <0.1 ppm
- Maximum Feedwater SDI (15min): 5.0
- Maximum Feedwater Turbidity: 1.0 NTU
- Feedwater pH Range: 3.0 – 10.0
- Minimum ratio of concentrate to permeate flow: 5:1
Feed water
- Test Conditions (for listed permeate flow and salt rejection):
- NaCl solution: 200 ppm
- Applied Pressure: 50 psi (3.5 bar)
- Operating Temperature: 77 °F (25 °C)
- Permeate Recovery: 15%
- pH Range: 6.5 – 7.0
Product water
- Permeate Flow: 150 gpd (568 l/d)
- Note: Minimum permeate flow for individual elements is 15 percent below listed flow.
- Salt Rejection (nominal): 97.5%
- Salt Rejection (minimum): 96.0%
Mechanical / hydraulic
- Dimensions:
- Total Length (A): 11.7 inches (298 mm)
- ATD Diameter (B): 1.9 inches (48.2 mm)
- Connection Diameter (C): 0.67 inches (17.0 mm)
- Core Tube Extension: 0.83 inches (21.0 mm)
- Weight: 0.5 lbs (0.23 Kg)
Additional Information
- Permeate obtained from the first hour of operation should be discarded.
- Avoid static permeate-side backpressure at all times.
- These membranes may be subject to drinking water application restrictions in some countries; check the application status before use and sale.
- For element loading, use only glycerine to lubricate o-rings and brine seal.
- Elements are dry and vacuum sealed in a polyethylene bag.
- The presence of free chlorine and other oxidizing agents will cause membrane failure, and the damage is not covered under warranty.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions present in the official PDF datasheet. Contractual data must match the OEM PDF revision used on the project.