Advantage™ AF Filter Cartridges (Mega-Pure)

Product identification

  • Series: Mega-Pure Membrane Series
  • Cartridge Code: AF (All Fluoropolymer)
  • Membrane: Hydrophobic PTFE
  • Pore Sizes: 0.05 µm, 0.1 µm, 0.2 µm, 0.45 µm, 1 µm
  • Special Preparation: Prewetted with Ozonated UHP Water (optional)
  • End Cap Configurations: BC, DC, HH, SC, TC (See official PDF for details on each code, e.g., TC = 222 O-Ring/Flat)

Operating limits

  • Maximum Temperature: 302°F (150°C) at 20 ∆P (1.4 bar)
  • Maximum Differential Pressure:
    • Forward: 70 psi (4.8 bar) at 77°F (25°C)
    • Forward: 30 psi (2.1 bar) at 315°F (157°C)
    • Reverse: 50 psi (3.4 bar) at 77°F (25°C)

Mechanical / hydraulic

  • Materials of Construction:
    • Membrane: hydrophobic PTFE
    • Membrane Support/Drainage: PFA
    • Structural Components: PFA
    • Sealing Method: thermal welding
    • Seal Material: various (CR 570, EPDM, KR 4079, PFA/Viton*, Viton*, No O-Ring options)
  • Dimensions:
    • Outside Diameter: 2.5 in (63.5 mm)
    • Inside Diameter: 0.825 in (22.2 mm)
    • Lengths: 2-30 in (10-76 cm)
  • Surface Area (10 in cartridge): Minimum 6.5 ft² (0.9 m²)

Product water

  • Quality Standard:
    • Flushed with pulsed UHP ozonated water.
    • Release criteria: no TOC contribution (ppb) and less than 4 particles/ml at the rating or greater for 15 minutes.
    • Metallic ion contribution: cannot exceed 25 ppb (after 24-hour static soak in 10% HNO₃).
  • Resistivity: Rinsed to 18 megohm-cm resistivity with pulsed, ozonated, UHP water.
  • Biosafe: In accordance with USP Class VI-121°C Plastics Tests.
  • FDA Compliance: All materials of construction are FDA listed as acceptable for potable and edible liquid contact according to CFR Title 21.

Integrity Test

  • Bubble Point (Using N₂ and membrane wet with 100% IPA at 73°F [23°C]):
    • 0.05 µm: > 50 psi (3.4 bar)
    • 0.1 µm: > 24 psi (1.7 bar)
    • 0.2 µm: > 16 psi (1.1 bar)
    • 0.45 µm: > 6 psi (0.4 bar)
    • 1 µm: > 3 psi (0.2 bar)

Flow Factors (1 cps liquid @ 73°F [23°C])

  • 4 in cartridge:
    • 0.05 µm: 0.6 GPM/1 PSID, 33 LPM/1 Bar, 1.7 PSID/1 GPM, 0.031 Bar/1 LPM
    • 0.1 µm: 1.0 GPM/1 PSID, 55 LPM/1 Bar, 1.0 PSID/1 GPM, 0.018 Bar/1 LPM
    • 0.2 µm: 1.5 GPM/1 PSID, 82 LPM/1 Bar, 0.7 PSID/1 GPM, 0.013 Bar/1 LPM
    • 0.45 µm: 2.0 GPM/1 PSID, 110 LPM/1 Bar, 0.5 PSID/1 GPM, 0.009 Bar/1 LPM
    • 1 µm: 2.4 GPM/1 PSID, 132 LPM/1 Bar, 0.4 PSID/1 GPM, 0.007 Bar/1 LPM
  • 10 in cartridge:
    • 0.05 µm: 1.5 GPM/1 PSID, 82 LPM/1 Bar, 0.67 PSID/1 GPM, 0.012 Bar/1 LPM
    • 0.1 µm: 2.5 GPM/1 PSID, 137 LPM/1 Bar, 0.40 PSID/1 GPM, 0.007 Bar/1 LPM
    • 0.2 µm: 3.5 GPM/1 PSID, 192 LPM/1 Bar, 0.30 PSID/1 GPM, 0.005 Bar/1 LPM
    • 0.45 µm: 5.0 GPM/1 PSID, 274 LPM/1 Bar, 0.20 PSID/1 GPM, 0.004 Bar/1 LPM
    • 1 µm: 6.0 GPM/1 PSID, 329 LPM/1 Bar, 0.17 PSID/1 GPM, 0.003 Bar/1 LPM

Advantage™ AF+ Filter Cartridges (Mega-Pure)

Product identification

  • Series: Mega-Pure Membrane Series
  • Cartridge Code: AF (All Fluoropolymer)
  • Membrane: Hydrophobic PTFE
  • Pore Sizes: 0.05 µm, 0.1 µm, 0.2 µm, 0.45 µm, 1 µm
  • Special Preparation: Prewetted with Ozonated UHP Water (optional)
  • End Cap Configuration: TC = 222 O-Ring/Flat

Operating limits

  • Maximum Temperature: 375°F (191°C) at 20 ∆P (1.4 bar)
  • Maximum Differential Pressure:
    • Forward: 70 psi (4.8 bar) at 77°F (25°C)
    • Forward: 30 psi (2.1 bar) at 315°F (157°C)
    • Reverse: 50 psi (3.4 bar) at 77°F (25°C)

Mechanical / hydraulic

  • Materials of Construction:
    • Membrane: hydrophobic PTFE
    • Membrane Support/Drainage: PFA
    • Core, Sleeve, Adaptors: PFA/PTFE alloy
    • End Caps: PFA
    • Sealing Method: thermal welding
    • Seal Material: various (CR 570, EPDM, KR 4079, PFA/Viton*, Viton*, No O-Ring options)
  • Dimensions:
    • Outside Diameter: 3.25 in (82.6 mm)
    • Inside Diameter: 1.125 in (29 mm)
    • Lengths: 4-30 in (10-76 cm)
  • Surface Area (10 in cartridge): Minimum 10.5 ft² (0.9 m²)

Product water

  • Quality Standard:
    • Flushed with pulsed UHP ozonated water.
    • Release criteria: no TOC contribution (ppb) and less than 4 particles/ml at the rating or greater for 15 minutes.
    • Metallic ion contribution: cannot exceed 25 ppb (after 24-hour static soak in 10% HNO₃).
  • Resistivity: Rinsed to 18 megohm-cm resistivity with pulsed, ozonated, UHP water.
  • Biosafe: In accordance with USP Class VI-121°C Plastics Tests.
  • FDA Compliance: All materials of construction are FDA listed as acceptable for potable and edible liquid contact according to CFR Title 21.

Integrity Test

  • Bubble Point (Using N₂ and membrane wet with 100% IPA at 73°F [23°C]):
    • 0.05 µm: > 50 psi (3.4 bar)
    • 0.1 µm: > 24 psi (1.7 bar)
    • 0.2 µm: > 16 psi (1.1 bar)
    • 0.45 µm: > 6 psi (0.4 bar)
    • 1 µm: > 3 psi (0.2 bar)

Flow Factors (1 cps liquid @ 73°F [23°C])

  • 4 in cartridge:
    • 0.05 µm: 0.8 GPM/1 PSID, 44 LPM/1 Bar, 1.3 PSID/1 GPM, 0.024 Bar/1 LPM
    • 0.1 µm: 1.3 GPM/1 PSID, 71 LPM/1 Bar, 0.8 PSID/1 GPM, 0.015 Bar/1 LPM
    • 0.2 µm: 2.0 GPM/1 PSID, 110 LPM/1 Bar, 0.5 PSID/1 GPM, 0.009 Bar/1 LPM
    • 0.45 µm: 2.8 GPM/1 PSID, 153 LPM/1 Bar, 0.4 PSID/1 GPM, 0.007 Bar/1 LPM
    • 1 µm: 3.3 GPM/1 PSID, 181 LPM/1 Bar, 0.3 PSID/1 GPM, 0.005 Bar/1 LPM
  • 10 in cartridge:
    • 0.05 µm: 2.0 GPM/1 PSID, 110 LPM/1 Bar, 0.50 PSID/1 GPM, 0.009 Bar/1 LPM
    • 0.1 µm: 3.3 GPM/1 PSID, 181 LPM/1 Bar, 0.30 PSID/1 GPM, 0.005 Bar/1 LPM
    • 0.2 µm: 5.0 GPM/1 PSID, 274 LPM/1 Bar, 0.20 PSID/1 GPM, 0.004 Bar/1 LPM
    • 0.45 µm: 7.1 GPM/1 PSID, 389 LPM/1 Bar, 0.14 PSID/1 GPM, 0.003 Bar/1 LPM
    • 1 µm: 8.3 GPM/1 PSID, 455 LPM/1 Bar, 0.12 PSID/1 GPM, 0.003 Bar/1 LPM

Advantage™ PS Filter Cartridges (Ultra-Pure)

Product identification

  • Series: Ultra-Pure Polyethersulfone Membrane Series
  • Cartridge Code: PS (Polyethersulfone)
  • Grade: U (Ultra-Pure)
  • Membrane: Hydrophilic polyethersulfone
  • Pore Sizes: 0.1 µm, 0.2 µm, 0.45 µm, 0.65 µm (0.03 µm also listed in ordering information)
  • End Cap Configurations: AR, HH, LL, LR, PR, SC, SF, TC, TF (See official PDF for details)

Operating limits

  • Maximum Temperature: 176°F (80°C) @ 30 ∆P (2.1 bar)
  • Maximum Differential Pressure:
    • Forward: 70 psi (4.8 bar) @ 77°F (25°C)
    • Forward: 30 psi (2.1 bar) @ 176°F (80°C)
    • Reverse: 50 psi (3.4 bar) @ 77°F (25°C)

Mechanical / hydraulic

  • Materials of Construction:
    • Membrane: hydrophilic polyethersulfone
    • Membrane Support/Drainage: polypropylene
    • Core/Cage: polypropylene
    • End Fittings: polypropylene
    • Sealing Method: thermal welding
    • Seal Material: various (Buna N, EPDM, Silicone, PFA/Viton*, Viton*, No O-Ring/No Gaskets options)
  • Dimensions:
    • Diameter: 2.70 in (6.8 cm)
    • Lengths: 10-40 in (25-102 cm)
  • Surface Area (10 in cartridge): Minimum 6.5 ft² (0.6 m²)

Product water

  • Endotoxins: < 0.25 EU/ml
  • FDA Compliance: All materials of construction are FDA listed as acceptable for potable and edible liquid contact according to CFR Title 21.
  • Resistivity: Rinsed with 18 megohm-cm UHP water.
  • Biosafe: In accordance with USP Class VI-121°C Plastics Tests.

Integrity Test

  • Bubble Point (in UHP water):
    • 0.1 µm > 70 psig (4.8 bar)
    • 0.2 µm > 45 psig (3.1 bar)
    • 0.45 µm > 24 psig (1.7 bar)
    • 0.65 µm > 16 psig (1.1 bar)
  • Diffusion Rate (10 in cartridge):
    • 0.1 µm < 33 cc/min at 40 psig (2.7 bar)
    • 0.2 µm < 33 cc/min at 30 psig (2.1 bar)
    • 0.45 µm < 33 cc/min at 15 psig (1.0 bar)
    • 0.65 µm < 33 cc/min at 10 psig (0.7 bar)

Sterilization/Sanitization Methods

  • Hot Water: 190°F (88°C)
  • Autoclave: 250°F (121°C) for 30 minutes at 15 psi (1.0 bar)
  • In situ Steam: 284°F (140°C) for 60 minutes at 15 psi (1.0 bar)
  • Chlorine
  • Hydrogen Peroxide
  • Sodium Hypochlorite
  • Sanitizing Agents (see Materials Selection Guide)

Flow Factors (1 cps liquid @ 73°F [23°C])

  • 0.1 µm: 1.8 GPM/1 PSID, 99 LPM/1 Bar, 0.56 PSID/1 GPM, 0.010 Bar/1 LPM
  • 0.2 µm: 3.5 GPM/1 PSID, 192 LPM/1 Bar, 0.29 PSID/1 GPM, 0.005 Bar/1 LPM
  • 0.45 µm: 5.5 GPM/1 PSID, 301 LPM/1 Bar, 0.18 PSID/1 GPM, 0.003 Bar/1 LPM
  • 0.65 µm: 6.5 GPM/1 PSID, 356 LPM/1 Bar, 0.15 PSID/1 GPM, 0.003 Bar/1 LPM

Advantage™ PS Filter Cartridges (Mega-Pure)

Product identification

  • Series: Mega-Pure Polyethersulfone Membrane Series
  • Cartridge Code: PS (Polyethersulfone)
  • Grade: E (Electronics)
  • Membrane: Hydrophilic polyethersulfone
  • Pore Sizes: 0.03 µm, 0.1 µm, 0.2 µm, 0.45 µm
  • End Cap Configurations: HH, SC, SF, TC, TF (See official PDF for details)

Operating limits

  • Maximum Temperature: 176°F (80°C) @ 30 ∆P (2.1 bar)
  • Maximum Differential Pressure:
    • Forward: 70 psi (4.8 bar) @ 77°F (25°C)
    • Forward: 30 psi (2.1 bar) @ 176°F (80°C)
    • Reverse: 50 psi (3.4 bar) @ 77°F (25°C)

Mechanical / hydraulic

  • Materials of Construction:
    • Membrane: hydrophilic polyethersulfone
    • Membrane Support/Drainage: polypropylene
    • Structural Components: polypropylene
    • Sealing Method: thermal welding
    • Seal Material: various (Buna N, EPDM, Silicone, PFA/Viton*, Viton*, No O-Ring options)
  • Dimensions:
    • Diameter: 2.7 in (6.8 cm)
    • Lengths: 10-40 in (25-102 cm)
  • Surface Area (10 in cartridge): Minimum 6.5 ft² (0.6 m²)

Product water

  • Resistivity: Rinsed to 18 megohm-cm resistivity with UHP water.
  • Biosafe: In accordance with USP Class VI-121°C Plastics Tests.
  • FDA Compliance: All materials of construction are FDA listed as acceptable for potable and edible liquid contact according to CFR Title 21.

Integrity Test

  • Bubble Point (in UHP water):
    • 0.03 µm > 90 psig (6.2 bar)
    • 0.1 µm > 70 psig (4.8 bar)
    • 0.2 µm > 45 psig (3.1 bar)
    • 0.45 µm > 24 psig (1.7 bar)
  • Diffusion Rate (10 in cartridge):
    • 0.03 µm < 33 cc/min at 45 psig (3.1 bar)
    • 0.1 µm < 33 cc/min at 40 psig (2.7 bar)
    • 0.2 µm < 33 cc/min at 30 psig (2.1 bar)
    • 0.45 µm < 33 cc/min at 15 psig (1.0 bar)

Flow Factors (1 cps liquid @ 73°F [23°C])

  • 0.03 µm: 1.2 GPM/1 PSID, 66 LPM/1 Bar, 0.85 PSID/1 GPM, 0.015 Bar/1 LPM
  • 0.1 µm: 1.8 GPM/1 PSID, 99 LPM/1 Bar, 0.56 PSID/1 GPM, 0.010 Bar/1 LPM
  • 0.2 µm: 3.5 GPM/1 PSID, 192 LPM/1 Bar, 0.29 PSID/1 GPM, 0.005 Bar/1 LPM
  • 0.45 µm: 5.5 GPM/1 PSID, 301 LPM/1 Bar, 0.18 PSID/1 GPM, 0.003 Bar/1 LPM

Advantage™ PS Filter Cartridges (General Grade)

Product identification

  • Series: General Grade Polyethersulfone Membrane Series
  • Cartridge Code: PS (Polyethersulfone)
  • Grade: G (General)
  • Membrane: Hydrophilic polyethersulfone
  • Pore Sizes: 0.03 µm, 0.1 µm, 0.2 µm, 0.45 µm, 0.65 µm
  • End Cap Configurations: AR, HH, LL, LR, PR, SC, SF, TC, TF (See official PDF for details)

Operating limits

  • Maximum Temperature: 176°F (80°C) @ 30 ∆P (2.1 bar)
  • Maximum Differential Pressure:
    • Forward: 70 psi (4.8 bar) @ 77°F (25°C)
    • Forward: 30 psi (2.1 bar) @ 176°F (80°C)
    • Reverse: 50 psi (3.4 bar) @ 77°F (25°C)

Mechanical / hydraulic

  • Materials of Construction:
    • Membrane: hydrophilic polyethersulfone
    • Membrane Support/Drainage: polypropylene
    • Structural Components: polypropylene
    • Sealing Method: thermal welding
    • Seal Material: various (Buna-N, EPR, Silicone, PFA/Viton*, Viton*, No O-Ring/No Gaskets options)
  • Dimensions:
    • Diameter: 2.7 in (6.8 cm)
    • Lengths: 10-40 in (25-102 cm)
  • Surface Area (10 in cartridge): Minimum 6.5 ft² (0.6 m²)

Product water

  • Endotoxins: < 0.25 eu/ml
  • FDA Compliance: All materials of construction are FDA listed as acceptable for potable and edible liquid contact according to CFR Title 21.
  • Installation Rinse-In: Cartridges typically rinse to background resistivity in less than five minutes at 2 gpm/10" equivalent.
  • Biosafe: In accordance with USP Class VI-121°C Plastics Tests.

Sterilization/Sanitization Methods

  • Isopropyl Alcohol
  • Sodium Hydroxide
  • Hydrogen Peroxide
  • Hot Water: 190°F (88°C) @ 5 psid (0.3 bar)
  • Autoclave: 250°F (121°C) for 30 minutes at 15 psi (1.0 bar)
  • In Situ Steam: 284°F (140°C) for 60 minutes at 15 psi (1.0 bar)
  • Chlorine
  • Sodium Hypochlorite
  • Sanitizing Agents (see Materials Selection Guide, Bulletin C-770)

Flow Factors (1 cps liquid @ 73°F [23°C])

  • 0.03 µm: 1.2 GPM/1 PSID, 66 LPM/1 Bar, 0.85 PSID/1 GPM, 0.015 Bar/1 LPM
  • 0.1 µm: 1.8 GPM/1 PSID, 99 LPM/1 Bar, 0.56 PSID/1 GPM, 0.010 Bar/1 LPM
  • 0.2 µm: 3.5 GPM/1 PSID, 192 LPM/1 Bar, 0.29 PSID/1 GPM, 0.005 Bar/1 LPM
  • 0.45 µm: 5.5 GPM/1 PSID, 301 LPM/1 Bar, 0.18 PSID/1 GPM, 0.003 Bar/1 LPM
  • 0.65 µm: 6.5 GPM/1 PSID, 356 LPM/1 Bar, 0.15 PSID/1 GPM, 0.003 Bar/1 LPM

Evadur™ Filter Cartridge

Product identification

  • Evadur™ is a high purity polyethersulfone membrane cartridge.
  • Designed for demanding water and chemical filtration applications.

Disclaimer: This summary is based solely on the provided text extract. It may not include all figures, footnotes, or the latest revisions present in the complete OEM PDF datasheet. For contractual data or full technical specifications, refer to the official Parker Hannifin Corporation PDF document.