Datasheet summary
RO-2600 RO Drinking water system
Engineering summary from PDF text extraction for RO-2600 RO Drinking water system. Verify every value with the OEM datasheet.
Summary
Product identification
- PENTAIR RO-2600 5 STAGE RO SYSTEM WITH PUMP
- HRO Booster Pump Model: 8015-014-011
Operating limits
- Pressure range: 1.4–6.9 bar
- Temperature range: 4.4-37.7°C
- pH limits: 3–11
Feed water
- Total dissolved solids: 2000 ppm
- Maximum hardness: 171 mg/L (Note: If hardness exceeds 171 mg/L, lime scale will build up rapidly on the membrane, making the system ineffective.)
- Sulfide, iron, and manganese: <0.1 ppm (maximum total level)
- Chlorine in water supply: <2 ppm
- Turbidity: 5 NTU Max
Product water
- Daily product water rate: 227 Lpd
- TDS rejection: 90% @ 2 bar inlet
Electrical
- Voltage (pump): 24 Vdc
- Amps (pump): 2.2
Mechanical / hydraulic
- System Dimensions & Weight:
- Overall dimensions: 45.7 x 20.3 x 45.7 cm
- System Weight: 10.4 kg
- Tank Specifications:
- Tank dimensions: 34.3 x 27.9 cm
- Tank capacity max: 16.5 L
- Tank air pressure empty: 0.34-0.48 bar
- Tank weight full: 12.9 kg
- RO System Components:
- Membrane: Thin Layer Composite membrane: TLC-75
- Sediment cartridge P5
- Carbon block cartridge EPM 10
- Granular activated carbon cartridge GAC 10
- Inline cartridge GS-10 RO
- HRO Booster Pump Specifications:
- Ports: ⅜ inch NPT-F
- Bypass: 5.5 bar
- Pump design: positive displacement diaphragm pump
- Motor: 24 Vdc permanent magnet motor, CE listed
Performance
- Product water flow rate at different inlet pressures:
- 1.4 bar: 181 Lph
- 2.8 bar: 166 Lph
- 4.1 bar: 151 Lph
- 5.5 bar: 113 Lph
- 6.9 bar: 41 Lph
Disclaimer: This summary is based on the provided text extract. It may not include all figures, footnotes, or the latest revisions found in the complete OEM PDF datasheet. Contractual data must match the specific OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.