TR-2012-50

Engineering summary from PDF text extraction for TR-2012-50. Verify every value with the OEM datasheet.

Summary

Product Identification

  • Model: TR-2012
  • Description: 2.0 x 12 Inch - Home Drinking Water RO Membranes
  • Membrane Type: Aromatic Polyamide Composite
  • Element Configuration: Spiral Wound, Tape Wrap

Performance Specification

  • Test Conditions:
    • Temperature: 25 °C (77 °F)
    • Feed Solution, Concentration: Tap water, 300 ppm
    • Feed Pressure: 4.5 bar (65 psi)
    • Brine : Permeate ratio: 5 : 1
    • Feed pH: 6.5 - 7.5
  • Performance Data:
ModelSalt Rejection (Average)¹Salt Rejection (Minimum)³Product Flow Rate (Average)²Product Flow Rate (Minimum)⁴
TR-2012-5096%96%190 l/day-15% for any single element
TR-2012-7596%96%290 l/d-15% for any single element
TR-2012-10096%96%375 l/d-15% for any single element
TR-2012-12596%96%470 l/d-15% for any single element

¹Average value for 100 elements after 1 hour operation. ²Flow rate is for the listed model under test conditions. ³Minimum rejection for any single element. ⁴Minimum flow for any single element.

Operating Limits

  • Recommended Operating Pressure: 4.5 bar (65 psi)
  • Maximum Operating Pressure: 8.6 bar (124 psi)
  • Operating Temperature (Recommended): < 35 °C (95 °F)
  • Maximum Operating Temperature: 45 °C (113 °F)
  • Feedwater Turbidity (SDI₁₅): < 4
  • Feedwater Chlorine Concentration: 0 ppm (< 1’000 ppm·h at < 0.1 ppm Cl₂ in absence of heavy metals)
  • pH Range (Feed and Brine): 2 - 11
  • Brine/Permeate Flow Ratio: 5 : 1

Mechanical / Hydraulic

  • Dimensions (mm / inches):
    • Overall Length: 293 mm (11.5")
    • Active Length: 264 mm (10.4")
    • Outer Diameter: 55 mm (2.2")
    • Permeate Tube Outer Diameter: 19 mm (0.75")
    • Other Dimensions (refer to diagram for exact position): 47.5 mm (1.87"), 10 mm (0.4"), 17.2 mm (0.68")