Datasheet summary

TR70-2514-HF

Engineering summary from PDF text extraction for TR70-2514-HF. Verify every value with the OEM datasheet.

Summary

Product identification

  • Models: TR70-2514-F, TR70-2514-HF, TRH-2514
  • Membrane Type: Crosslinked Aromatic Polyamide, Negative Charge
  • Element Configuration: Spiral Wound, Tape Wrap
  • Element Size Description: 2.5 x 14 INCH TAPE WRAP BRACKISH ELEMENTS

Performance Specifications

This section outlines the nominal performance characteristics of the membrane elements under specified test conditions.

Models and Nominal Performance:

ModelDescriptionSalt Rejection avg.¹,²Product Flow Rate¹,²Test Conditions
TR70-2514-FNormal Flux99.4 %850 l/d (225 gpd)A
TR70-2514-HFHigh Flow99.4 %1000 l/d (265 gpd)A
TRH-2514Low Pressure, High Flow99.0 %700 l/d (185 gpd)B

Standard Test Conditions:

  • Condition A:
    • Temperature: 25 °C
    • Feed Solution Concentration: 1500 ppm NaCl
    • Feed Pressure: 15 bar
    • Brine : Permeate ratio: 5 : 1
    • Feed pH: 6.5 - 7.5
  • Condition B:
    • Temperature: 25 °C
    • Feed Solution Concentration: 500 ppm NaCl
    • Feed Pressure: 7.5 bar
    • Brine : Permeate ratio: 5 : 1
    • Feed pH: 6.5 - 7.5

Notes on Performance:

  • ¹ Average value for 100 elements after 1 hour operation.
  • ² Product Flow Rate ± 15%. Salt Rejection minimum 98%.
  • Minimum Performance data are for any single element.

Operating limits

The following are recommended design and operating conditions for safe and effective membrane life. Operating outside these ranges may reduce effective membrane life.

  • Recommended Operating Pressure: < 15.0 kg/cm² (216 psi)
    • Maximum Operating Pressure: 20 kg/cm² (288 psi)
  • Operating Temperature: < 35 °C (95 °F)
    • Maximum Operating Temperature: 35 °C (95 °F)
  • pH Range, Continuous Operation: 3 - 11 (Both feed and brine water must meet this range.)
  • pH Range, Chemical Cleaning: 2 - 11

Feed water

  • Feedwater Turbidity (SDI₁₅): < 5 (SDI₁₅ = Silt Density Index measured according to ASTM D4189). High flux operation on feedwater turbidity greater than 3 or 4 SDI₁₅ generally results in frequent cleaning requirements.
  • Feedwater Chlorine Concentration: 0 ppm

Mechanical / hydraulic

  • Feed Flow Rate per Vessel: < 650 l/h (3 gpm)
  • Brine Flow Rate per Vessel: > 250 l/h (1 gpm). This figure may be reduced when there is low possibility of fouling and scaling.
  • Brine/Permeate Flow Ratio: 5 : 1 (Flow ratio of brine to permeate for each single element.)
  • Pressure Drop (per Element): 0.5 kg/cm² (7 psi)
  • Pressure Drop (per Vessel): 1.0 kg/cm² (14 psi)
    • Element(s) must be cleaned when pressure drop increases to 1.5 times of the initial value.