TR70-2521-HF

Engineering summary from PDF text extraction for TR70-2521-HF. Verify every value with the OEM datasheet.

Summary

Product identification

  • Model Numbers: TR70-2521-HF & TRH-2521 (2.5 x 21 INCH TAPE WRAP BRACKISH ELEMENTS)
  • Membrane Type: Crosslinked Aromatic Polyamide, Negative Charge
  • Element Configuration: Spiral Wound, Tape Wrap

Performance Specification

ModelDescriptionSalt Rejection avg.¹,²Product Flow Rate¹‚²Test Conditions
TR70-2521-FNormal Flux99.4 %1’200 l/d (315 gpd)A
TR70-2521-HFHigh Flow99.4 %1’600 l/d (420 gpd)A
TRH-2521Low Pressure, High Flow99.0 %1’400 l/d (370 gpd)B

Test Conditions:

  • Condition A:
    • Temperature: 25 °C
    • Feed Solution, Concentration: 1500 ppm NaCl
    • Feed Pressure: 15 bar
    • Brine : Permeate ratio: 5 : 1
    • Feed pH: 6.5 - 7.5
  • Condition B:
    • Temperature: 25 °C
    • Feed Solution, Concentration: 500 ppm NaCl
    • Feed Pressure: 7.5 bar
    • Brine : Permeate ratio: 5 : 1
    • Feed pH: 6.5 - 7.5

Notes on Performance:

  • Average value for 100 elements after 1 hour operation.
  • Product Flow Rate +/- 15%.
  • Salt Rejection minimum 98%.
  • Minimum Performance data are for any single element.

Operating limits

The recommended design range signifies safe operational and design conditions under not-so-much fouling and scaling. Operating outside this range may reduce effective membrane life.

  • Operating Pressure:
    • Recommended: < 15.0 kg/cm² (216 psi)
    • Maximum: 20 kg/cm² (288 psi)
  • Operating Temperature: < 35 °C (95 °F)
  • Feedwater Turbidity (SDI₁₅): < 5 (High flux operation on feedwater turbidity > 3 or 4 SDI₁₅ generally results in frequent cleaning requirements.)
  • Feedwater Chlorine Concentration: 0 ppm
  • pH Range, Continuous Operation: 3 - 11 (Both feed and brine water must meet this range.)
  • pH Range, Chemical Cleaning: 2 - 11 (Cleaning and sterilization must meet the recommendations in the Technical Bulletin.)
  • Feed Flow Rate per Vessel: < 650 l/h (3 gpm)
  • Brine Flow Rate per Vessel: > 250 l/h (1 gpm) (This figure may be reduced when there is low possibility of fouling and scaling.)
  • Brine/Permeate Flow Ratio: 5 : 1 (Flow ratio of brine to permeate for each single element.)

Mechanical / hydraulic

  • Pressure Drop:

    • Per Element: 0.3 kg/cm² (4 psi)
    • Per Vessel: 1.0 kg/cm² (14 psi)
    • Element(s) must be cleaned when pressure drop increases to 1.5 times of the initial value.
  • Dimensions:

    • Total Length: 21’’ (533 mm)
    • Diameter (approx.): 4’’ inch (101 mm)
    • Permeate tube outer diameter: 0.75’’
    • Other dimensions shown as 19’’ (482 mm), 1’’ (25.4 mm), 2.4’’ (61 mm) in diagram referencing unspecified features. See the official PDF for exact tabulated values and diagrams.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.