Back to Ropur Membranes
Lanxess logo

Datasheet summary

TR70-4014-HF

Engineering summary from PDF text extraction for TR70-4014-HF. Verify every value with the OEM datasheet.

Summary

Product identification

  • Models: TR70-4014-HF, TRH-4014
  • Membrane Type: Crosslinked Aromatic Polyamide, Negative Charge
  • Element Configuration: Spiral Wound, Tape Wrap
  • Size: 4 x 14 INCH

Performance specification

ModelSalt Rejection avg.¹²Product Flow Rate¹²
TR70-4014-F99.4 %2’200 l/d (580 gpd)
TR70-4014-HF99.4 %2900 l/d (765 gpd)
TRH-401499.0 %2400 l/d (635 gpd)

Notes:

  1. Test Conditions: Performance for TR70-4014-F and TR70-4014-HF are based on Condition A. Performance for TRH-4014 is based on Condition B.
  2. Average value for 100 elements after 1 hour operation. Product Flow Rate ± 15%. Salt Rejection minimum 98 %.
  3. Minimum Performance data are for any single element.

Test Conditions

ParameterCondition ACondition B
Temperature25 °C25 °C
Feed Solution, Concentration1500 ppm NaCl500 ppm NaCl
Feed Pressure15 bar7.5 bar
Brine : Permeate ratio5 : 15 : 1
Feed pH6.5 - 7.56.5 - 7.5

Operating limits

  • Recommended Operating Pressure: < 15.0 kg/cm² (216 psi)
    • Maximum: 20 kg/cm² (288 psi)
  • Operating Temperature: < 35 °C (95 °F)
    • Maximum: 35 °C (95 °F)
  • Feedwater Turbidity (SDI₁₅): < 5
    • High flux operation on feedwater turbidity greater than 3 or 4 SDI₁₅ generally results in frequent cleaning requirements. SDI₁₅ is measured according to ASTM D4189.
  • Feedwater Chlorine Concentration: 0 ppm
  • pH Range, Continuous Operation: 3 - 11 (both feed and brine water must meet this range)
  • pH Range, Chemical Cleaning: 3 - 11
  • Feed Flow Rate per Vessel: < 2’200 l/h (10 gpm)
  • Brine Flow Rate per Vessel: > 600 l/h (2.6 gpm)
  • Brine/Permeate Flow Ratio (per element): 5 : 1
  • Pressure Drop (per Element): 0.5 kg/cm² (7 psi)
  • Pressure Drop (per Vessel): 1.0 kg/cm² (14 psi)
    • Element(s) must be cleaned when pressure drop increases to 1.5 times of the initial value.

Mechanical / hydraulic

Dimensions for the element are provided in a diagram showing various lengths and diameters. See the official PDF for exact tabulated values and a visual representation. Key features include an Identification Tape, Brine Seal, and Anti Telescoping Device.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. For contractual data, always refer to the specific OEM PDF revision used on your project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.