Datasheet summary
TR70-4040-HF
Engineering summary from PDF text extraction for TR70-4040-HF. Verify every value with the OEM datasheet.
Summary
Product Identification
The elements are 4 x 40 inch tape wrap brackish elements. Models include TR70-4040-HF and TRH-4040.
- Membrane Type: Crosslinked Aromatic Polyamide, Negative Charge
- Element Configuration: Spiral Wound, Tape Wrap
Performance Specification
Model TR70-4040-HF
- Description: High Flow
- Salt Rejection avg.¹²: 99.4 %
- Product Flow Rate¹²: 11’900 l/d (3’140 gpd)
Other Models (for comparison)
- TR70-4040-F: Normal Flux
- Salt Rejection avg.¹²: 99.4 %
- Product Flow Rate¹²: 8’900 l/d (2’350 gpd)
- TRH-4040: Low Pressure, High Flow
- Salt Rejection avg.¹²: 99.0 %
- Product Flow Rate¹²: 10’300 l/d (2’720 gpd)
Test Conditions
Condition A (for TR70-4040-F & TR70-4040-HF)
- Temperature: 25 °C
- Feed Solution, Concentration: 1500 ppm NaCl
- Feed Pressure: 15 bar
- Brine : Permeate ratio: 5 : 1
- Feed pH: 6.5 - 7.5
Condition B (for TRH-4040)
- Temperature: 25 °C
- Feed Solution, Concentration: 500 ppm NaCl
- Feed Pressure: 7.5 bar
- Brine : Permeate ratio: 5 : 1
- Feed pH: 6.5 - 7.5
Notes: ¹ Average value for 100 elements after 1 hour operation. ² Product Flow Rate +/- 15%. Salt Rejection minimum 98 %. Minimum performance data are for any single element.
Operating Limits / Design Conditions
The following are recommended design conditions for safe operation under conditions with not much fouling and scaling. Operating outside these ranges may reduce effective membrane life.
- Operating Pressure: < 15.0 kg/cm² (216 psi)
- Maximum: 20 kg/cm² (288 psi)
- Operating Temperature: < 35 °C (95 °F)
- Maximum: 35 °C (95 °F)
- Feedwater Turbidity (SDI₁₅): < 5
- High flux operation on feedwater turbidity greater than 3 or 4 SDI₁₅ generally results in frequent cleaning requirements.
- Feedwater Chlorine Concentration: 0 ppm
- pH Range, Continuous Operation: 3 - 11
- Both feed and brine water must meet this range.
- pH Range, Chemical Cleaning: 3 - 11
- Feed Flow Rate per Vessel: < 2’200 l/h (10 gpm)
- Brine Flow Rate per Vessel: > 600 l/h (2.6 gpm)
- This figure may be reduced when there is low possibility of fouling and scaling.
- Brine/Permeate Flow Ratio: 5 : 1 (for each single element)
- Pressure Drop (per Element): 0.5 kg/cm² (7 psi)
- Pressure Drop (per Vessel): 1.0 kg/cm² (14 psi)
- Element(s) must be cleaned when pressure drop increases to 1.5 times of the initial value.
Mechanical / Hydraulic
The elements are approximately 4 inches in diameter and 40 inches long.
- Length: 40'' (1016 mm)
- Diameter: 4'' inch (101 mm)
- Permeate Tube Diameter (A): 0.75'' (19 mm)
- Permeate Tube Diameter (B): 1'' (25.4 mm)
- Element body diameter (excluding brine seal): 3.9'' (99 mm)
Disclaimer
This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions present in the official PDF datasheet. For contractual data, always refer to the specific OEM PDF revision used on the project.
Official datasheet (PDF)