Back to Ropur Membranes
Lanxess logo

Datasheet summary

TRH-2514

Engineering summary from PDF text extraction for TRH-2514. Verify every value with the OEM datasheet.

Summary

Product identification

These reverse osmosis membrane elements are TR70-2514-HF and TRH-2514. The datasheet also describes the TR70-2514-F model. They are 2.5 x 14 inch tape wrap brackish elements.

  • Membrane Type: Crosslinked Aromatic Polyamide, Negative Charge
  • Element Configuration: Spiral Wound, Tape Wrap

Performance Specification

ModelFlux TypeSalt Rejection (avg.)Product Flow Rate (avg.)Test Conditions
TR70-2514-FNormal Flux99.4 %850 l/d (225 gpd)A
TR70-2514-HFHigh Flow99.4 %1000 l/d (265 gpd)A
TRH-2514Low Pressure, High Flow99.0 %700 l/d (185 gpd)B

Test Conditions:

ParameterCondition ACondition BUnit
Temperature2525°C
Feed Solution, Concentration1500500ppm NaCl
Feed Pressure157.5bar
Brine : Permeate ratio5 : 15 : 1
Feed pH6.5 - 7.56.5 - 7.5

Notes:

  • Average values are for 100 elements after 1 hour operation.
  • Product Flow Rate tolerance: ± 15%
  • Minimum Salt Rejection: 98 % for any single element.

Operating limits

  • Recommended Operating Pressure: < 15.0 kg/cm² (216 psi)
  • Maximum Operating Pressure: 20 kg/cm² (288 psi)
  • Operating Temperature: < 35 °C (95 °F)
  • Maximum Operating Temperature: 35 °C (95 °F)
  • Feedwater Turbidity (SDI₁₅): < 5
  • Feedwater Chlorine Concentration: 0 ppm
  • pH Range, Continuous Operation: 3 - 11 (applies to both feed and brine water)
  • pH Range, Chemical Cleaning: 2 - 11
  • Feed Flow Rate per Vessel: < 650 l/h (3 gpm)
  • Brine Flow Rate per Vessel: > 250 l/h (1 gpm)
  • Brine/Permeate Flow Ratio (per element): 5 : 1

Mechanical / hydraulic

  • Pressure Drop (per Element): 0.5 kg/cm² (7 psi)
  • Pressure Drop (per Vessel): 1.0 kg/cm² (14 psi)
  • Elements must be cleaned when pressure drop increases to 1.5 times of the initial value.

The elements have an approximate diameter of 2.5 inches and a length of 14 inches. Detailed dimensions for permeate tubes, anti-telescoping devices, and overall element are provided in the source PDF. See the official PDF for exact tabulated values.


Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.