Datasheet summary
TRH-2540
Engineering summary from PDF text extraction for TRH-2540. Verify every value with the OEM datasheet.
Summary
Product Identification
- Model: TR70-2540-HF, TRH-2540 (also TR70-2540-F)
- Size: 2.5 x 40 inch
- Membrane Type: Crosslinked Aromatic Polyamide, Negative Charge
- Element Configuration: Spiral Wound, Tape Wrap
Performance Specifications
| Model | Characteristic | Salt Rejection avg.¹,² | Product Flow Rate¹,² | Test Conditions |
|---|---|---|---|---|
| TR70-2540-F | Normal Flux | 99.4 % | 2’600 l/d (685 gpd) | A |
| TR70-2540-HF | High Flow | 99.4 % | 3’600 l/d (950 gpd) | A |
| TRH-2540 | Low Pressure, High Flow | 99.0 % | 3’200 l/d (845 gpd) | B |
Notes on Performance:
- Average value for 100 elements after 1 hour operation.
- Product Flow Rate +/- 15%.
- Salt Rejection minimum 98 %. Minimum performance data are for any single element.
Test Conditions
| Parameter | Condition A | Condition B | Unit |
|---|---|---|---|
| Temperature | 25 | 25 | °C |
| Feed Solution, Concentration | 1500 | 500 | ppm NaCl |
| Feed Pressure | 15 | 7.5 | bar |
| Brine : Permeate ratio | 5 : 1 | 5 : 1 | |
| Feed pH | 6.5 - 7.5 | 6.5 - 7.5 |
Operating Limits
- Recommended Operating Pressure: < 15.0 kg/cm² (216 psi)
- Maximum: 20 kg/cm² (288 psi)
- Operating Temperature: < 35 °C (95 °F)
- Maximum: 35 °C (95 °F)
- Feedwater Turbidity (SDI₁₅): < 5
- Feedwater Chlorine Concentration: 0 ppm
- pH Range, Continuous Operation: 3-11 (Both feed and brine water must meet this range)
- pH Range, Chemical Cleaning: 2-11
- Feed Flow Rate per Vessel: < 650 l/h (3 gpm)
- Brine Flow Rate per Vessel: > 250 l/h (1 gpm)
- Brine/Permeate Flow Ratio: 5 : 1 (for each single element)
- Pressure Drop (per Element): 0.5 kg/cm² (7 psi)
- Pressure Drop (per Vessel): 1.0 kg/cm² (14 psi)
Notes on Operating Limits:
- The recommended design range signifies safe operational and design conditions under low fouling and scaling. Operating outside this range may reduce effective membrane life.
- High flux operation (high permeate flow rate per single element) with feedwater turbidity greater than 3 or 4 SDI₁₅ generally leads to frequent cleaning. Operating pressure should be set to maintain the desired flux rate.
- SDI₁₅ is measured according to ASTM D4189.
- Cleaning and sterilization must follow recommendations in the Technical Bulletin.
- The Brine Flow Rate per Vessel may be reduced when there is a low possibility of fouling and scaling.
- Elements must be cleaned when pressure drop increases to 1.5 times the initial value.
Mechanical / Hydraulic
- Overall Length: 40’’ (1016 mm)
- Diameter: 4’’ inch (101 mm)
- Permeate Tube Dimensions: 0.75’’ (19 mm), 1’’ (25.4 mm)
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. For contractual data, always refer to the official OEM PDF revision used on the project.