Back to Ropur Membranes
Lanxess logo

Datasheet summary

TRH-4014

Engineering summary from PDF text extraction for TRH-4014. Verify every value with the OEM datasheet.

Summary

Product identification

These are ROPUR Membranes 4 x 14 INCH Tape Wrap Brackish Elements.

  • Models: TR70-4014-HF, TRH-4014
  • Membrane Type: Crosslinked Aromatic Polyamide, Negative Charge
  • Element Configuration: Spiral Wound, Tape Wrap

Performance Specification

Models:

  • TR70-4014-F: Normal Flux
  • TR70-4014-HF: High Flow
  • TRH-4014: Low Pressure, High Flow
ParameterTR70-4014-FTR70-4014-HFTRH-4014
Salt Rejection avg.99.4 %99.4 %99.0 %
Product Flow Rate2’200 l/d (580 gpd)2900 l/d (765 gpd)2400 l/d (635 gpd)
Test conditionsAAB

Test Conditions:

ParameterAB
Temperature25 °C25 °C
Feed Solution, Concentration1500 ppm NaCl500 ppm NaCl
Feed Pressure15 bar7.5 bar
Brine : Permeate ratio5 : 15 : 1
Feed pH6.5 - 7.56.5 - 7.5

Notes on performance:

  • Average value for 100 elements after 1 hour operation.
  • Product Flow Rate +/- 15%.
  • Salt Rejection minimum 98 %.
  • Minimum Performance data are for any single element.

Operating limits

  • Recommended Operating Pressure: < 15.0 kg/cm² (216 psi)
  • Maximum Operating Pressure: 20 kg/cm² (288 psi)
  • Recommended Operating Temperature: < 35 °C (95 °F)
  • Maximum Operating Temperature: 35 °C (95 °F)
  • pH Range, Continuous Operation: 3 - 11 (Both feed and brine water must meet this range.)
  • pH Range, Chemical Cleaning: 3 - 11

Feed water

  • Feedwater Turbidity (SDI₁₅): < 5
  • Feedwater Chlorine Concentration: 0 ppm
  • pH Range, Continuous Operation: 3 - 11

Product water

  • Minimum Salt Rejection: 98 %

Mechanical / hydraulic

  • Nominal Dimensions:
    • Diameter: 4'' inch (101 mm)
    • Length: 14'' (355 mm)
    • For detailed dimensions and diagrams, refer to the official PDF.
  • Feed Flow Rate per Vessel: < 2’200 l/h (10 gpm)
  • Brine Flow Rate per Vessel: > 600 l/h (2.6 gpm)
  • Brine/Permeate Flow Ratio: 5 : 1
  • Pressure Drop (per Element): 0.5 kg/cm² (7 psi)
  • Pressure Drop (per Vessel): 1.0 kg/cm² (14 psi)
    • Elements must be cleaned when pressure drop increases to 1.5 times of the initial value.

Disclaimer: This summary is based solely on the provided text extract. It may not include all figures, footnotes, or the latest revisions found in the complete OEM PDF datasheet. For contractual data, always refer to the specific OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.