Back to Ropur Membranes
Lanxess logo

Datasheet summary

TRH-4021

Engineering summary from PDF text extraction for TRH-4021. Verify every value with the OEM datasheet.

Summary

Product identification

  • Model: TR70-4021-HF & TRH-4021 (4 x 21 INCH TAPE WRAP BRACKISH ELEMENT)
  • Membrane Type: Crosslinked Aromatic Polyamide, Negative Charge
  • Element Configuration: Spiral Wound, Tape Wrap
  • Approximate Dimensions:
    • Diameter: 4'' inch (101 mm)
    • Length: 21'' (533 mm)
    • Permeate tube diameter: 0.75'' (19 mm)
    • Permeate tube length (visible): 19'' (482 mm)
    • Element body length: 3.9'' (99 mm)

Performance Specification

ModelDescriptionSalt Rejection (avg.)¹´²Product Flow Rate¹´²Test Conditions
TR70-4021-FNormal Flux99.4 %4’000 l/d (1’055 gpd)A
TR70-4021-HFHigh Flow99.4 %5’400 l/d (1’425 gpd)A
TRH-4021Low Pressure, High Flow99.0 %4’700 l/d (1’240 gpd)B

Test Conditions:

ParameterCondition ACondition BUnit
Temperature2525°C
Feed Solution, Concentration1500500ppm NaCl
Feed Pressure157.5bar
Brine : Permeate ratio5 : 15 : 1-
Feed pH6.5 - 7.56.5 - 7.5-

Notes on Performance:

  1. Average value for 100 elements after 1 hour operation.
  2. Product Flow Rate ± 15%. Salt Rejection minimum 98%.
  3. Minimum Performance data are for any single element.

Operating limits

  • Recommended Operating Pressure: < 15.0 kg/cm² (216 psi)
  • Maximum Operating Pressure: 20 kg/cm² (288 psi)
  • Recommended Operating Temperature: < 35 °C (95 °F)
  • Maximum Operating Temperature: 35 °C (95 °F)
  • Feedwater Turbidity (SDI₁₅): < 5
  • Feedwater Chlorine Concentration: 0 ppm
  • pH Range, Continuous Operation: 3 - 11
  • pH Range, Chemical Cleaning: 3 - 11
  • Feed Flow Rate per Vessel: < 2’200 l/h (10 gpm)
  • Brine Flow Rate per Vessel: > 600 l/h (2.6 gpm)
  • Brine/Permeate Flow Ratio: 5 : 1
  • Pressure Drop (per Element): 0.5 kg/cm² (7 psi)
  • Pressure Drop (per Vessel): 1.0 kg/cm² (14 psi)
  • Pressure Drop Cleaning Trigger: Element(s) must be cleaned when pressure drop increases to 1.5 times of the initial value.

Disclaimer: This summary is based on the provided text extract. It may not include all figures, footnotes, or the latest revisions found in the complete OEM PDF datasheet. Contractual data must match the specific OEM PDF revision used for your project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.