Back to Synder Membranes
Synder logo

Datasheet summary

LY PES 100kDa

Engineering summary from PDF text extraction for LY PES 100kDa. Verify every value with the OEM datasheet.

Summary

Product identification

Ultrafiltration Spiral-Wound Element: LY (PES 100kDa)

Membrane Type

  • Proprietary PVDF or PES
  • Spiral-Wound with netted outerwrap or fiber glass hardshell (FRP)

Industrial Series Benefits

  • Widest range of UF MWCO’s available
  • Good resistance to pH and temperature
  • High resistance to fouling
  • Customizable dimensions for unique housings

Operating limits

Pressure

  • Max Inlet Pressure: 116 PSI (8.0 Bar)
  • Min Outlet Pressure: 10 PSI (0.7 Bar)
  • Max Differential Pressure per Element: 18 PSI (1.2 Bar)
  • Max Permeate Backpressure: 5 PSI (0.3 Bar)
    • Note: Soft start on boost pumps required to minimize pressure/flow shocks to elements.

Temperature

  • Max. Operating: 122°F (50°C)
  • Max. CIP Temperature: 122°F (50°C)

pH Parameters

  • pH Range during Operation at 25°C Max.: 1.0-11.0
  • pH Range during CIP Operation at 50°C Max.: 2.0-11.0

Peroxide

  • Free Peroxide in Product During Operation: <3 ppm
  • Peroxide as a sanitizer at 25°C Max, pH 6-7, 10 minutes recirculation: 0.1%

Chlorine

  • Free Chlorine During Operation: 0 Norm ppm (<0.1 Max ppm)
  • Chlorine During CIP at pH 10.8-11.0 and 50°C: 150 Norm ppm (180 Max ppm)
    • Note: Maximum chlorine exposure for all elements is 30 minutes per day at pH and temperature conditions listed above.

Mechanical / hydraulic

Dimensions & Weight

ElementModel No.Diameter (B) in (cm)Length (A) in (cm)PWT ID/OD in (cm)Tube Extension (C) in (cm)Dry Weight lb (kg)
1.8”1812TM1.8” (4.6)11.75” (29.8)0.665” (1.71)0.75” (perm), 1.00” (plug)1.0 (0.45)
2.5”2540TM2.4” (6.1)40.0” (101.6)0.75” (1.90)1.00” (2.54)4.0 (1.8)
2540HF2.4” (6.1)40.0” (101.6)0.625” (1.59)-4.0 (1.8)
2540HM2.4” (6.1)40.0” (101.6)0.75” (1.90)1.00” (2.54)4.0 (1.8)
4”4040TM3.9” (9.9)40.0” (101.6)0.75” (1.90)1.00” (2.54)12.0 (5.5)
4040HM3.9” (9.9)40.0” (101.6)0.75” (1.90)1.00” (2.54)12.0 (5.5)
4040HF3.9” (9.9)40.0” (101.6)0.625” (1.59)-12.0 (5.5)
8”7940HF7.9” (20.1)40.0” (101.6)1.138” (2.89)-35.0 (15.9)
8040HF7.9” (20.1)40.0” (101.6)1.125” (2.86)-35.0 (15.9)

Membrane Area (sq. ft)

ElementFeed Spacer (in mils) 24Feed Spacer (in mils) 31Feed Spacer (in mils) 46Feed Spacer (in mils) 65Feed Spacer (in mils) 80
1812TM3.12.72.11.61.3
2540M2824201613
2540F3026221714
4040M8172584639
4040F8675614941
7940F379335268210178
8040F379335268210178

Recommended Element Cross Flow Rate

ElementFeed Spacer (in mils) 24Feed Spacer (in mils) 31Feed Spacer (in mils) 46Feed Spacer (in mils) 65Feed Spacer (in mils) 80
1.8”
m³/hr0.70.80.91.01.1
gpm33445
2.5”
m³/hr1.31.51.82.02.1
gpm67899
4.0”
m³/hr34555
gpm1517202324
8”
m³/hr1517202324
gpm66758999105
Note: The recommended cross flow rate will be subject to differential pressure limitations and specific applications.

Common Applications

  • Corn wet milling

Technical Notes

For element sizes not listed, contact Synder Filtration for details. Elements can be designed to fit specific needs by specifying the element outer diameter (OD) or vessel/housing inner diameter (ID), element inner diameter (ID), and length. Elements are also available with or without a controlled bypass tail. Additional feed spacers are also available. Trials should be conducted to determine optimal application conditions.


Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.