Datasheet summary
MQ PES 50kDa
Engineering summary from PDF text extraction for MQ PES 50kDa. Verify every value with the OEM datasheet.
Summary
Industrial Ultrafiltration Spiral-Wound Element: MQ (PES 50kDa)
Synder Filtration's Ultrafiltration Elements offer an optimal combination of both flux and rejection across a comprehensive range of Molecular Weight Cut-Offs (MWCO's).
Product identification
- Membrane Type: Proprietary PVDF or PES
- Construction: Spiral-Wound with netted outerwrap or fiberglass hardshell (FRP)
Operating limits
Pressure
- Max Inlet Pressure: 116 PSI (8.0 Bar)
- Min Outlet Pressure: 10 PSI (0.7 Bar)
- Max Differential Pressure per Element: 18 PSI (1.2 Bar)
- Max Permeate Backpressure: 5 PSI (0.3 Bar)
- Note: Soft start on boost pumps required to minimize pressure/flow shocks to elements.
Temperature
- Max. Operating Temperature: 122°F (50°C)
- Max. CIP Temperature: 122°F (50°C)
pH Parameters
- pH Range during Operation at 25°C Max.: 1.0-11.0
- pH Range during CIP Operation at 50°C Max.: 2.0-11.0
Peroxide
- Free Peroxide in Product During Operation: <3 ppm
- Peroxide as a sanitizer at 25°C Max, pH6-7, 10 minutes recirculation: 0.1%
Chlorine
- Free Chlorine During Operation: 0 Norm ppm (<0.1 Max ppm)
- Chlorine During CIP at pH10.8-11.0 and 50°C: 150 Norm ppm (180 Max ppm)
- Note: Maximum chlorine exposure for all elements is 30 minutes per day at pH and temperature conditions listed above.
Industrial Series Benefits
- Widest range of UF MWCO’s available
- Good resistance to pH and temperature
- High resistance to fouling
- Customizable dimensions for unique housings
Common Applications
- Specialty protein separation
- Beverage clarification
Mechanical / hydraulic
Dimensions & Weight
| Element | Model No. | Diameter (B) in (cm) | Length (A) in (cm) | PWT ID/OD in (cm) | Tube Extension (C) in (cm) | Dry Weight lb (kg) |
|---|---|---|---|---|---|---|
| 1.8” | 1812TM | 1.8” (4.6) | 11.75” (29.8) | 0.665” (1.71) | 0.75” (perm), 1.00” (plug) | 1.0 (.45) |
| 2.5” | 2540TM | 2.4” (6.1) | 40.0” (101.6) | 0.75” (1.90) | 1.00” (2.54) | 4.0 (1.8) |
| 2540HF | 2.4” (6.1) | 40.0” (101.6) | 0.625” (1.59) | - | 4.0 (1.8) | |
| 2540HM | 2.4” (6.1) | 40.0” (101.6) | 0.75” (1.90) | 1.00” (2.54) | 4.0 (1.8) | |
| 4” | 4040TM | 3.9” (9.9) | 40.0” (101.6) | 0.75” (1.90) | 1.00” (2.54) | 12.0 (5.5) |
| 4040HM | 3.9” (9.9) | 40.0” (101.6) | 0.75” (1.90) | 1.00” (2.54) | 12.0 (5.5) | |
| 4040HF | 3.9” (9.9) | 40.0” (101.6) | 0.625” (1.59) | - | 12.0 (5.5) | |
| 8” | 7940HF | 7.9” (20.1) | 40.0” (101.6) | 1.138” (2.89) | - | 35.0 (15.9) |
| 8040HF | 7.9” (20.1) | 40.0” (101.6) | 1.125” (2.86) | - | 35.0 (15.9) |
Membrane Area (sq. ft)
(Feed Spacer in mils)
| Element | 24 | 31 | 46 | 65 | 80 |
|---|---|---|---|---|---|
| 1812TM | 3.1 | 2.7 | 2.1 | 1.6 | 1.3 |
| 2540M | 28 | 24 | 20 | 16 | 13 |
| 2540F | 30 | 26 | 22 | 17 | 14 |
| 4040M | 81 | 72 | 58 | 46 | 39 |
| 4040F | 86 | 75 | 61 | 49 | 41 |
| 7940F | 379 | 335 | 268 | 210 | 178 |
| 8040F | 379 | 335 | 268 | 210 | 178 |
Recommended Element Cross Flow Rate
(Feed Spacer in mils)
| Element | Unit | 24 | 31 | 46 | 65 | 80 |
|---|---|---|---|---|---|---|
| 1.8” | m³/hr | 0.7 | 0.8 | 0.9 | 1.0 | 1.1 |
| gpm | 3 | 3 | 4 | 4 | 5 | |
| 2.5” | m³/hr | 1.3 | 1.5 | 1.8 | 2.0 | 2.1 |
| gpm | 6 | 7 | 8 | 9 | 9 | |
| 4.0” | m³/hr | 3 | 4 | 5 | 5 | 5 |
| gpm | 15 | 17 | 20 | 23 | 24 | |
| 8” | m³/hr | 15 | 17 | 20 | 23 | 24 |
| gpm | 66 | 75 | 89 | 99 | 105 |
Note: The recommended cross flow rate will be subject to differential pressure limitations and specific applications.