Datasheet summary
NFG TFC 600-800Da
Engineering summary from PDF text extraction for NFG TFC 600-800Da. Verify every value with the OEM datasheet.
Summary
Product identification
Synder Filtration's Nanofiltration membranes are engineered to provide superior separation performance. This Nanofiltration TFC Spiral-Wound Element, NFG (600-800Da), is known for its stable flux and wide range of rejection to monovalent and divalent ions, specifically developed for specialty process applications.
Operating limits
- Maximum Operating Pressure:
- 600psi (4,137kPa) if T <95°F (35°C)
- 435psi (3,000kPa) if T >95°F (35°C)
- Maximum Temperature: 50°C (122°F)
- pH Range @ Max Temperature: 4-9
- pH Range @ Ambient Temperature: 4-10
- Chlorine Tolerance: 500ppm hours, dechlorination recommended
Cleaning parameters
- Maximum Temperature (Short term <30min): 50°C (122°F)
- pH Range @ Max Temperature: 3-10
- pH Range @ Ambient Temperature: 3-10.5
Mechanical / hydraulic
Pressure Drop
- Maximum per Element: 15psi (103kPa)
- Maximum per Housing: 60psi (414kPa)
Element Dimensions & Weight
| Element Model Number | Diameter (B) in (cm) | Length (A) in (cm) | PWT ID/OD in (cm) | Tube Extension (C) in (cm) | Dry Weight lb (kg) |
|---|---|---|---|---|---|
| 1.8” | |||||
| 1812TM | 1.8” (4.6) | 11.75” (29.8) | 0.675” (1.71) | 0.75” (1.90) | 1.0 (0.9) |
| 2.5” | |||||
| 2519HF | 2.4” (6.1) | 19.0” (48.3) | 0.625” (1.59) | - | 3.0 (1.4) |
| 2540TM | 2.4” (6.1) | 40.0” (101.6) | 0.75” (1.90) | 1.0” (2.54) | 6.0 (2.7) |
| 2540HF | 2.4” (6.1) | 40.0” (101.6) | 0.625” (1.59) | - | 6.0 (2.7) |
| 2540HM | 2.4” (6.1) | 40.0” (101.6) | 0.75” (1.90) | 1.0” (2.54) | 6.0 (2.7) |
| 4” | |||||
| 4040TM | 3.9” (9.9) | 40.0” (101.6) | 0.75” (1.90) | - | 12.0 (5.5) |
| 4040HM | 3.9” (9.9) | 40.0” (101.6) | 0.75” (1.90) | 1.0” (2.54) | 12.0 (5.5) |
| 4040HF | 3.9” (9.9) | 40.0” (101.6) | 0.625” (1.59) | - | 12.0 (5.5) |
| 8” | |||||
| 8040HF | 7.9” (20.1) | 40.0” (101.6) | 1.125” (2.86) | - | 35.0 (15.9) |
NF Membrane Area (sq. ft.)
| Element | Feed Spacer (in mils) |
|---|---|
| 24 | |
| 1812TM | 4 |
| 2540HF | 35 |
| 2540HM | 33 |
| 4040HF | 99 |
| 4040HM | 96 |
| 8040HF | 440 |
Recommended Element Cross Flow Rate
| Element | Feed Spacer (in mils) |
|---|---|
| 24 | |
| 1.8” | |
| m³/hr | 0.4 |
| gpm | 1.8 |
| 2.5” | |
| m³/hr | 1.2 |
| gpm | 5 |
| 4” | |
| m³/hr | 2 |
| gpm | 10 |
| 8” | |
| m³/hr | 10 |
| gpm | 43 |
The recommended cross flow rate is subject to differential pressure limitations and specific applications.
Membrane Specs
- Model: NFG
- Polymer: Proprietary PA TFC
- Approx. Molecular Weight Cutoff: 600-800Da
- Typical Operating Flux: 55-60 GFD
- Min Lactose Rejection¹: 60.0%
- Avg MgSO₄ Rejection²: 50.0%
- Avg NaCl Rejection³: 10.0%
¹Test Conditions: 2,000ppm Lactose solution at 110psi (760kPa) operating pressure, 77°F (25°C) ²Test Conditions: 2,000ppm MgSO₄ solution at 110psi (760kPa) operating pressure, 77°F (25°C) ³Test Conditions: 2,000ppm NaCl solution at 110psi (760kPa) operating pressure, 77°F (25°C)
Benefits
- Operation at lower pressures than Reverse Osmosis membranes while achieving excellent rejection of divalent and multivalent ions.
- Greatly reduce levels of hardness, nitrates, sulfates, tannins, turbidity, color, TDS, and moderate levels of salt from feed water streams.
Technical Notes
For element sizes not listed, custom elements can be designed to fit specific needs by specifying outer diameter (OD) or vessel/housing inner diameter (ID), element inner diameter (ID), and length. Elements are also available with or without a controlled bypass tail. Additional feed spacers are available. Trials should be conducted to determine optimal application conditions.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. For contractual data, always refer to the official OEM PDF revision used on your project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.