Back to Synder Membranes
Synder logo

Datasheet summary

NFW TFC 300-500Da

Engineering summary from PDF text extraction for NFW TFC 300-500Da. Verify every value with the OEM datasheet.

Summary

Product Identification

  • Product type: Nanofiltration TFC Spiral-Wound Element
  • Series: NFW (300-500Da)
  • Polymer: Proprietary PA TFC
  • Approx. Molecular Weight Cutoff: 300-500Da
  • Typical Operating Flux: 45-50 GFD

Typical Rejection Rates (Test Conditions: 2,000ppm solution at 110psi (760kPa), 77°F (25°C))

  • Min Lactose Rejection: 98.5%
  • Avg MgSO₄ Rejection: 97.0%
  • Avg NaCl Rejection: 20.0%

Benefits

  • Operation at lower pressures than Reverse Osmosis membranes while achieving excellent rejection of divalent and multivalent ions.
  • Greatly reduce levels of hardness, nitrates, sulfates, tannins, turbidity, color, TDS, and moderate levels of salt from feed water streams.

Operating Limits

Recommended Operating Parameters

  • Maximum Operating Pressure:
    • 600psi (4,137kPa) if T <95°F (35°C)
    • 435psi (3,000kPa) if T >95°F (35°C)
  • Maximum Temperature: 50°C (122°F)
  • pH Range @ Max Temperature: 4-9
  • pH Range @ Ambient Temperature: 4-10

Cleaning Parameters

  • Maximum Temperature (Short term <30min): 50°C (122°F)
  • pH Range @ Max Temperature: 3-10
  • pH Range @ Ambient Temperature: 3-10.5

Pressure Drop

  • Maximum per Element: 15psi (103kPa)
  • Maximum per Housing: 60psi (414kPa)

Chlorine Tolerance

  • 500ppm hours, dechlorination recommended

Mechanical / Hydraulic

Element Dimensions & Weight

Element Model NumberDiameter (B) in (cm)Length (A) in (cm)PWT ID/OD in (cm)Tube Extension (C) in (cm)Dry Weight lb (kg)
1.8”
1812TM1.8” (4.6)11.75” (29.8)0.675” (1.71)0.75” (1.90)1.0 (0.9)
2.5”
2519HF2.4” (6.1)19.0” (48.3)0.625” (1.59)-3.0 (1.4)
2540TM2.4” (6.1)40.0” (101.6)0.75” (1.90)1.0” (2.54)6.0 (2.7)
2540HF2.4” (6.1)40.0” (101.6)0.625” (1.59)-6.0 (2.7)
2540HM2.4” (6.1)40.0” (101.6)0.75” (1.90)1.0” (2.54)6.0 (2.7)
4”
4040TM3.9” (9.9)40.0” (101.6)0.75” (1.90)-12.0 (5.5)
4040HM3.9” (9.9)40.0” (101.6)0.75” (1.90)1.0” (2.54)12.0 (5.5)
4040HF3.9” (9.9)40.0” (101.6)0.625” (1.59)-12.0 (5.5)
8”
8040HF7.9” (20.1)40.0” (101.6)1.125” (2.86)-35.0 (15.9)

NF Membrane Area (sq. ft.)

Element24 mil31 mil46 mil65 mil80 mil
1812TM43.42.62.01.6
2540HF3530231715
2540HM3328211614
4040HF9987685143
4040HM9682645042
8040HF440380293227193

Recommended Element Cross Flow Rate

Element24 mil m³/hr (gpm)31 mil m³/hr (gpm)46 mil m³/hr (gpm)65 mil m³/hr (gpm)80 mil m³/hr (gpm)
1.8”
m³/hr0.40.50.60.60.6
gpm1.82.02.42.52.6
2.5”
m³/hr1.21.41.61.82.1
gpm56789
4”
m³/hr24556
gpm1018212324
8”
m³/hr1011131415
gpm4348556164

The recommended cross flow rate is subject to differential pressure limitations and specific applications.


Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data should always match the specific OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.