Back to Synder Membranes
Synder logo

Datasheet summary

PX PAN 400kDa

Engineering summary from PDF text extraction for PX PAN 400kDa. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Line: Synder Filtration Ultrafiltration Elements
  • Membrane Type: Polyacrylonitrile (PAN 400kDa)
  • Construction: Spiral-Wound with tape wrap or fiber glass hardshell (FRP)

Operating limits

Pressure

  • Max Inlet Pressure: 116 PSI (8.0 Bar)
  • Min Outlet Pressure: 10 PSI (0.7 Bar)
  • Max Differential Pressure per Element: 18 PSI (1.2 Bar)
  • Max Permeate Backpressure: 5 PSI (0.3 Bar)
    • Note: Soft start on boost pumps required to minimize pressure/flow shocks to elements.

Temperature

  • Max. Operating: 122-131°F (50-55°C)
  • Max. CIP Temperature: 122-131°F (50-55°C)

pH Parameters

  • pH Range during Operation at 25°C Max.: 3.0-10.0
  • pH Range during CIP Operation at 55°C Max.: 3.0-10.5

Peroxide

  • Free Peroxide in Product During Operation: <3 ppm
  • Peroxide as a Sanitizer at 25°C Max, pH 6-7, 10 minutes recirculation: 0.1%

Chlorine

  • Free Chlorine During Operation: 0 Norm ppm, <0.1 Max ppm
  • Chlorine During CIP at pH 10.5 and 55°C: 150 Norm ppm, 180 Max ppm
    • Note: Maximum chlorine exposure for all elements is 30 minutes per day at pH and temperature conditions listed above.

Mechanical / hydraulic

Dimensions & Weight

Element Model No.Diameter (B) in (cm)Length (A) in (cm)PWT ID/OD in (cm)Tube Extension (C) in (cm)Dry Weight lb (kg)
1.8”
1812TM1.8” (4.6)11.75” (29.8)0.665” (1.71)0.75” (perm), 1.00” (plug)1.0 (.45)
2.5”
2540TM2.4” (6.1)40.0” (101.6)0.75” (1.90)1.00” (2.54)4.0 (1.8)
2540HF2.4” (6.1)40.0” (101.6)0.625” (1.59)-4.0 (1.8)
2540HM2.4” (6.1)40.0” (101.6)0.75” (1.90)1.00” (2.54)4.0 (1.8)
4”
4040TM3.9” (9.9)40.0” (101.6)0.75” (1.90)1.00” (2.54)12.0 (5.5)
4040HM3.9” (9.9)40.0” (101.6)0.75” (1.90)1.00” (2.54)12.0 (5.5)
4040HF3.9” (9.9)40.0” (101.6)0.625” (1.59)-12.0 (5.5)
8”
7940HF7.9” (20.1)40.0” (101.6)1.138” (2.89)-35.0 (15.9)
8040HF7.9” (20.1)40.0” (101.6)1.125” (2.86)-35.0 (15.9)

Membrane Area (sq. ft)

Element24 mils31 mils46 mils65 mils80 mils
1812TM3.12.72.11.61.3
2540M2824201613
2540F3026221714
4040M8172584639
4040F8675614941
7940F379335268210178
8040F379335268210178

Recommended Element Cross Flow Rate

Element DiameterFeed Spacer (in mils)2431466580
1.8”m³/hr0.70.80.91.01.1
gpm33445
2.5”m³/hr1.31.51.82.02.1
gpm67899
4.0”m³/hr34555
gpm1517202324
8”m³/hr1517202324
gpm66758999105

Note: The recommended cross flow rate will be subject to differential pressure limitations and specific applications.

Industrial Series Benefits

  • Widest range of UF MWCO’s available
  • Good resistance to pH and temperature
  • High resistance to fouling
  • Customizable dimensions for unique housings

Common Applications

  • Oil removal in wastewater treatment

Disclaimer: This summary is generated from extracted text and may not include all figures, footnotes, or the latest revisions. For contractual data, always refer to the official OEM PDF revision used on your project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.