Datasheet summary
UF PZ
Engineering summary from PDF text extraction for UF PZ. Verify every value with the OEM datasheet.
Summary
Product identification
Synder Filtration's Industrial Ultrafiltration Spiral-Wound Element: PZ (PAN 30kDa)
- Membrane Type: Polyacrylonitrile
- Configuration: Spiral-Wound with tape wrap or fiber glass hardshell (FRP)
Operating limits
- Pressure
- Max Inlet Pressure: 116 PSI (8.0 Bar)
- Min Outlet Pressure: 10 PSI (0.7 Bar)
- Max Differential Pressure per Element: 18 PSI (1.2 Bar)
- Max Permeate Backpressure: 5 PSI (0.3 Bar)
- Note: Soft start on boost pumps required to minimize pressure/flow shocks to elements.
- Temperature
- Max. Operating: 122-131°F (50-55°C)
- Max. CIP Temperature: 122-131°F (50-55°C)
- pH Parameters
- pH Range during Operation at 25°C Max.: 3.0-10.0
- pH Range during CIP Operation at 55°C Max.: 3.0-10.5
- Peroxide
- Free Peroxide in Product During Operation: <3 ppm
- Peroxide as a Sanitizer at 25°C Max, pH 6-7, 10 minutes recirculation: 0.1%
- Chlorine
- Free Chlorine During Operation: 0 ppm (<0.1 ppm)
- Chlorine During CIP at pH 10.5 and 55°C: 150 ppm (Norm), 180 ppm (Max)
- Note: Maximum chlorine exposure for all elements is 30 minutes per day at pH and temperature conditions listed above.
Mechanical / Hydraulic
Dimensions & Weight
| Element | Model No. | Diameter (B) in (cm) | Length (A) in (cm) | PWT ID/OD in (cm) | Tube Extension (C) in (cm) | Dry Weight lb (kg) |
|---|---|---|---|---|---|---|
| 1.8” | 1812TM | 1.8” (4.6) | 11.75” (29.8) | 0.665” (1.71) | 0.75” (perm), 1.00” (plug) | 1.0 (.45) |
| 2.5” | 2540TM | 2.4” (6.1) | 40.0” (101.6) | 0.75” (1.90) | 1.00” (2.54) | 4.0 (1.8) |
| 2540HF | 2.4” (6.1) | 40.0” (101.6) | 0.625” (1.59) | - | 4.0 (1.8) | |
| 2540HM | 2.4” (6.1) | 40.0” (101.6) | 0.75” (1.90) | 1.00” (2.54) | 4.0 (1.8) | |
| 4” | 4040TM | 3.9” (9.9) | 40.0” (101.6) | 0.75” (1.90) | 1.00” (2.54) | 12.0 (5.5) |
| 4040HM | 3.9” (9.9) | 40.0” (101.6) | 0.75” (1.90) | 1.00” (2.54) | 12.0 (5.5) | |
| 4040HF | 3.9” (9.9) | 40.0” (101.6) | 0.625” (1.59) | - | 12.0 (5.5) | |
| 8” | 7940HF | 7.9” (20.1) | 40.0” (101.6) | 1.138” (2.89) | - | 35.0 (15.9) |
| 8040HF | 7.9” (20.1) | 40.0” (101.6) | 1.125” (2.86) | - | 35.0 (15.9) |
Membrane Area (sq ft)
| Element | Feed Spacer (in mils) | 24 | 31 | 46 | 65 | 80 |
|---|---|---|---|---|---|---|
| 1812TM | 3.1 | 2.7 | 2.1 | 1.6 | 1.3 | |
| 2540M | 28 | 24 | 20 | 16 | 13 | |
| 2540F | 30 | 26 | 22 | 17 | 14 | |
| 4040M | 81 | 72 | 58 | 46 | 39 | |
| 4040F | 86 | 75 | 61 | 49 | 41 | |
| 7940F | 379 | 335 | 268 | 210 | 178 | |
| 8040F | 379 | 335 | 268 | 210 | 178 |
Recommended Element Cross Flow Rate
| Element | Feed Spacer (in mils) | 24 | 31 | 46 | 65 | 80 |
|---|---|---|---|---|---|---|
| 1.8” | m³/hr | 0.7 | 0.8 | 0.9 | 1.0 | 1.1 |
| gpm | 3 | 3 | 4 | 4 | 5 | |
| 2.5” | m³/hr | 1.3 | 1.5 | 1.8 | 2.0 | 2.1 |
| gpm | 6 | 7 | 8 | 9 | 9 | |
| 4.0” | m³/hr | 3 | 4 | 5 | 5 | 5 |
| gpm | 15 | 17 | 20 | 23 | 24 | |
| 8” | m³/hr | 15 | 17 | 20 | 23 | 24 |
| gpm | 66 | 75 | 89 | 99 | 105 |
Note: The recommended cross flow rate will be subject to differential pressure limitations and specific applications.
Industrial Series Benefits
- Widest range of UF MWCO’s available
- Good resistance to pH and temperature
- High resistance to fouling
- Customizable dimensions for unique housings
Common Applications
- Oil removal in wastewater treatment
- Enzyme processing
Disclaimer: This summary is based on the provided text extraction and may not include all figures, footnotes, or the latest revisions from the original OEM PDF datasheet. For contractual purposes, data must match the specific OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.