Back to Synder Membranes
Synder logo

Datasheet summary

V0.2 PVDF 0.2um

Engineering summary from PDF text extraction for V0.2 PVDF 0.2um. Verify every value with the OEM datasheet.

Summary

Product identification

These are Industrial Microfiltration Spiral-Wound Elements, specifically the V0.2 (PVDF 0.2 µm) series.

  • Membrane Type: Proprietary PVDF or PES
  • Construction: Spiral-Wound with netted outerwrap or fiber glass hardshell (FRP)

Operating limits

  • Pressure
    • Max Inlet Pressure: 116 PSI (8.0 Bar)
    • Min Outlet Pressure: 10 PSI (0.7 Bar)
    • Max Differential Pressure per Element: 18 PSI (1.2 Bar)
    • Max Permeate Backpressure: 5 PSI (0.3 Bar)
    • Note: Soft start on boost pumps required to minimize pressure/flow shocks to elements.
  • Temperature
    • Max. Operating Temperature: 122°F (50°C)
    • Max. CIP Temperature: 122°F (50°C)
  • pH Parameters
    • pH Range during Operation at 25°C Max.: 1.0-11.0
    • pH Range during CIP Operation at 50°C Max.: 2.0-11.0
  • Peroxide
    • Free Peroxide in Product During Operation: <3 ppm
    • Peroxide as a sanitizer at 25°C Max, pH6-7, 10 minutes recirculation: 0.1%
  • Chlorine
    • Free Chlorine During Operation: 0 Norm ppm, <0.1 Max ppm
    • Chlorine During CIP at pH10.8-11.0 and 50°C: 150 Norm ppm, 180 Max ppm
    • Note: Maximum chlorine exposure for all elements is 30 minutes per day at pH and temperature conditions listed above.

Mechanical / hydraulic

Dimensions & Weight

ElementModel No.Diameter (B) in (cm)Length (A) in (cm)PWT ID/OD in (cm)Tube Extension (C) in (cm)Dry Weight lb (kg)
1.8”1812TM1.8” (4.6)11.75” (29.8)0.665” (1.71)0.75” (perm) <br> 1.00” (plug)1.0 (0.45)
2.5”2540TM2.4” (6.1)40.0” (101.6)0.75” (1.90)1.00” (2.54)4.0 (1.8)
2540HF2.4” (6.1)40.0” (101.6)0.625” (1.59)-4.0 (1.8)
2540HM2.4” (6.1)40.0” (101.6)0.75” (1.90)1.00” (2.54)4.0 (1.8)
4”4040TM3.9” (9.9)40.0” (101.6)0.75” (1.90)1.00” (2.54)12.0 (5.5)
4040HM3.9” (9.9)40.0” (101.6)0.75” (1.90)1.00” (2.54)12.0 (5.5)
4040HF3.9” (9.9)40.0” (101.6)0.625” (1.59)-12.0 (5.5)
8”7940HF7.9” (20.1)40.0” (101.6)1.138” (2.89)-35.0 (15.9)
8040HF7.9” (20.1)40.0” (101.6)1.125” (2.86)-35.0 (15.9)

Membrane Area (sq. ft)

ElementFeed Spacer (in mils) 24Feed Spacer (in mils) 31Feed Spacer (in mils) 46Feed Spacer (in mils) 65Feed Spacer (in mils) 80
1812TM3.12.72.11.61.3
2540M2824201613
2540F3026221714
4040M8172584639
4040F8675614941
7940F379335268210178
8040F379335268210178

Recommended Element Cross Flow Rate

ElementFeed Spacer (in mils) 24 (m³/hr)Feed Spacer (in mils) 24 (gpm)Feed Spacer (in mils) 31 (m³/hr)Feed Spacer (in mils) 31 (gpm)Feed Spacer (in mils) 46 (m³/hr)Feed Spacer (in mils) 46 (gpm)Feed Spacer (in mils) 65 (m³/hr)Feed Spacer (in mils) 65 (gpm)Feed Spacer (in mils) 80 (m³/hr)Feed Spacer (in mils) 80 (gpm)
1.8”0.730.830.941.041.15
2.5”1.361.571.882.092.19
4.0”315417520523524
8”156617752089239924105
Note: The recommended cross flow rate will be subject to differential pressure limitations and specific applications.

Technical Notes

For element sizes not listed, custom designs are available to fit specific needs, including outer diameter (OD) or vessel/housing inner diameter (ID), element inner diameter (ID), and length. Elements can be supplied with or without a controlled bypass tail, and additional feed spacers are available. Trials are recommended to determine optimal application conditions.

Benefits

  • Good resistance to pH and temperature
  • High resistance to fouling
  • Customizable dimensions for unique housings

Common Applications

  • Microbial removal
  • Enzyme clarification

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. For contractual data, always refer to the official OEM PDF revision used on the specific project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.