Back to Synder Membranes
Synder logo

Datasheet summary

V4 PVDF 70kDa

Engineering summary from PDF text extraction for V4 PVDF 70kDa. Verify every value with the OEM datasheet.

Summary

Product identification

The V4 (PVDF 70kDa) is an industrial Ultrafiltration (UF) spiral-wound E-Coat element.

  • Membrane Type: Proprietary PVDF
  • Membrane Construction: Round shell (net or FRP)
  • Approx. Molecular Weight Cutoff: 70,000

V-Series Features & Benefits

  • Proprietary positive charge to repel paint particles, promote maximum flux rates, and reduce fouling.
  • Membrane requires one cleaning chemical plus acid; no other additives.
  • Integrated end plugs for easy integration and removal.

Operating limits

  • Typical Operating Flux: 5-35 GFD (8-60 LMH)
  • Membrane Temperature:
    • Continuous Operation: 122°F (50°C)
    • Clean-In-Place (CIP): 110°F (43.3°C)
  • pH Range:
    • Continuous Operation: 1-11
    • Clean-In-Place (CIP): 2-10.5
  • Maximum Pressure Drop:
    • FRP Element: 35psi (241kPa)
    • Net Wrap Element: 17psi (117kPa)
  • Chlorine Tolerance: 180ppm maximum per cleaning cycle

Feed water

Common Applications

  • Cathodic electrocoat paint
  • Laundry waste water
  • Industrial water processes

Mechanical / hydraulic

Element Dimensions & Weight

Model #Body Length (mm)Element OD (mm)ID Perm Tube ID (mm)OD Perm Tube (mm)Tube Ext LengthFeed Rate GPM (lpm)Standard Housing
1812TM10.00” (254)1.8” (46)0.675” (17)0.75” (perm) 1.0” (plug)2.0 (7.6)IH-1812
2519H19.25” (489)2.5” (63.5)0.62” (15.8)6.0 (23)IH-2519
2540H38.00” (965.2)2.5” (63.5)0.75” (19.1)1.00” (both ends)6.0 (23)IH-2540
3940AH38.80” (985.5)3.93” (99.8)0.827” (21)0.60” (both ends)25 (95)
3945H45.00” (1143)3.93” (99.8)0.62” (15.8)25 (95)
4030H27.0” (658.8)3.93” (99.8)0.84” (21.3)3.00” (perm) 3.63” (plug)25 (95)IH-4030
4032H29.50” (749.3)3.93” (99.8)0.75” (19.1)1.06” (both ends)25 (95)
4033H33.00” (838.2)3.93” (99.8)0.62” (15.8)25 (95)
4037H27.00” (685.8)3.93” (99.8)0.84” (21.3)3.00” (perm) 8.625” (plug)25 (95)IH-KR4
4040AH40.00” (1016)3.93” (99.8)0.62” (15.8)25 (95)
4040BH40.00” (1016)3.93” (99.8)0.76” (19.3)25 (95)
4045BH40.00” (1016)3.93” (99.8)0.84” (21.3)3.00” (perm) 1.875” (plug)25 (95)IH-4042
4045CH45.00” (1143)3.93” (99.8)0.62” (15.8)25 (95)
4051.5H40.00” (1016)3.93” (99.8)0.84” (21.3)3.00” (perm) 8.50” (plug)25 (95)IH-40RF
5640H40.00” (1016)5.60” (142.2)1.29” (32.8)40 (151)
5647.5H40.00” (1016)5.60” (142.2)1.66” (42.2)3.00” (perm) 4.375” (plug)40 (151)IH-60A
5651.5H40.00” (1016)5.60” (142.2)1.66” (42.2)3.00” (perm) 8.375” (plug)40 (151)IH-60RF
7637H33.00” (838.2)7.45” (189.2)1.66” (42.2)2.00” (both ends)70 (265)
7640HB40.00” (1016)7.28” (184.9)1.29” (32.7)70 (265)
7640HC40.00” (1016)7.28” (184.9)1.29” (32.7)70 (265)
7647.5HB40.00” (1016)7.45” (189.2)1.66” (42.2)3.00” (perm) 4.375” (plug)70 (265)IH-80S
7647.5HC40.00” (1016)7.28” (184.9)1.66” (42.2)3.00” (perm) 4.375” (plug)70 (265)IH-80D(C,E)
7940HA38.25” (717.6)7.90” (200.7)1.66” (42.2)0.875” (both ends)80 (303)
F7940HA40.00” (1016)7.90” (200.7)1.139” (28.9)80 (303)
8040H40.00” (1016)7.90” (200.7)1.125” (28.6)80 (303)

Membrane Area (sq. ft)

ElementFeed Spacer (in mils)2431466580
1812TM3.12.72.11.61.3
2540M2622191412
2540F2723201513
4040M7767544336
4040F7969564538
8040F365317250193166

Recommended Element Cross Flow Rate

ElementFeed Spacer (in mils)2431466580
1.8”m³/hr11111
gpm33445
2.5”m³/hr12222
gpm67899
4.0”m³/hr34555
gpm1517202324
8”m³/hr1517202324
gpm66758999105

Note: The recommended cross flow rate will be subject to differential pressure limitations and specific applications.

Technical Notes

For element sizes not listed, Synder Filtration can design an element to fit exact needs by specifying element outer diameter (OD) or vessel/housing inner diameter (ID), element inner diameter (ID), and length. Additional feed spacers are also available.


Disclaimer: This summary is generated from an extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.