Back to Synder Membranes
Synder logo

Datasheet summary

VT PES 3kDa

Engineering summary from PDF text extraction for VT PES 3kDa. Verify every value with the OEM datasheet.

Summary

Product identification

Synder Filtration’s Ultrafiltration Spiral-Wound Element: VT (PES 3kDa)

  • Membrane Type: Proprietary PVDF or PES
  • Construction: Spiral-Wound with netted outerwrap or fiberglass hardshell (FRP)

Operating limits

  • Pressure
    • Max Inlet Pressure: 116 PSI (8.0 Bar)
    • Min Outlet Pressure: 10 PSI (0.7 Bar)
    • Max Differential Pressure per Element: 18 PSI (1.2 Bar)
    • Max Permeate Backpressure: 5 PSI (0.3 Bar)
    • Note: Soft start on boost pumps required to minimize pressure/flow shocks to elements.
  • Temperature
    • Max. Operating: 122°F (50°C)
    • Max. CIP Temperature: 122°F (50°C)
  • pH Parameters
    • pH Range during Operation at 25°C Max.: 1.0-11.0
    • pH Range during CIP Operation at 50°C Max.: 2.0-11.0
  • Peroxide
    • Max Free Peroxide in Product During Operation: <3 ppm
    • Peroxide as a sanitizer at 25°C Max, pH 6-7, 10 minutes recirculation: 0.1%
  • Chlorine
    • Max Free Chlorine During Operation: <0.1 ppm
    • Chlorine During CIP at pH 10.8-11.0 and 50°C: 180 ppm (Norm: 150 ppm)
    • Note: Maximum chlorine exposure for all elements is 30 minutes per day at pH and temperature conditions listed above.

Mechanical / hydraulic

Dimensions & Weight

ElementModel No.Diameter (B) in (cm)Length (A) in (cm)PWT ID/OD in (cm)Tube Extension (C) in (cm)Dry Weight lb (kg)
1.8”1812TM1.8” (4.6)11.75” (29.8)0.665” (1.71)0.75” (perm), 1.00” (plug)1.0 (0.45)
2.5”2540TM2.4” (6.1)40.0” (101.6)0.75” (1.90)1.00” (2.54)4.0 (1.8)
2540HF2.4” (6.1)40.0” (101.6)0.625” (1.59)-4.0 (1.8)
2540HM2.4” (6.1)40.0” (101.6)0.75” (1.90)1.00” (2.54)4.0 (1.8)
4”4040TM3.9” (9.9)40.0” (101.6)0.75” (1.90)1.00” (2.54)12.0 (5.5)
4040HM3.9” (9.9)40.0” (101.6)0.75” (1.90)1.00” (2.54)12.0 (5.5)
4040HF3.9” (9.9)40.0” (101.6)0.625” (1.59)-12.0 (5.5)
8”7940HF7.9” (20.1)40.0” (101.6)1.138” (2.89)-35.0 (15.9)
8040HF7.9” (20.1)40.0” (101.6)1.125” (2.86)-35.0 (15.9)

Membrane Area (sq. ft)

Element2431466580
1812TM3.12.72.11.61.3
2540M2824201613
2540F3026221714
4040M8172584639
4040F8675614941
7940F379335268210178
8040F379335268210178

Recommended Element Cross Flow Rate

ElementUnit2431466580
1.8”m³/hr0.70.80.91.01.1
gpm33445
2.5”m³/hr1.31.51.82.02.1
gpm67899
4.0”m³/hr34555
gpm1517202324
8”m³/hr1517202324
gpm66758999105

Note: The recommended cross flow rate will be subject to differential pressure limitations and specific applications.

Technical Notes

For element sizes not listed, custom elements can be designed to fit specific needs by specifying the element outer diameter (OD) or vessel/housing inner diameter (ID), element inner diameter (ID), and length. Elements are also available with or without a controlled bypass tail. Additional feed spacers are available. Trials should be conducted to determine optimal application conditions.

Applications

  • Antibiotic concentration
  • Protein & polypeptide concentration

Disclaimer: This summary is based solely on the extracted text provided. It may not include all figures, footnotes, or the latest revisions present in the official PDF datasheet. For contractual purposes, always refer to the specific OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.