Product identification
Synder Filtration's PHT Series of Ultrafiltration Elements, specifically the A6 (PVDF 500kDa) sanitary spiral-wound element. These elements are designed for exceptional physical and chemical durability.
PHT Series benefits include:
- Conforms to 3-A, FDA, and USDA sanitary standards
- Elimination of chlorine during CIP with hot sanitation
- High resistance to pH, temperature, & fouling
- Customizable dimensions for unique housings
Common applications:
- Anodic electrocoat paint
- Microbial/Particle removal
Operating limits
Operating Parameters
- Maximum Temperature: 60°C (140°F)
- pH Range @ Max Temperature: 3-10
- pH Range @ Ambient Temperature: 2-10.5
Pressure
- Max Inlet Pressure: 120 PSI (8.3 Bar)
- Min Outlet Pressure: 10 PSI (0.7 Bar)
- Max Differential Pressure per Element: 18 PSI (1.2 Bar)
- Max Permeate Backpressure: 5 PSI (0.3 Bar)
- Note: Soft start on boost pumps required to minimize pressure/flow shocks to elements.
Cleaning Parameters
- Maximum Temperature (Short term <30min): 85°C (185°F)
- pH Range @ Max Temperature: 2-11
- pH Range @ Ambient Temperature: 2-12
Chlorine
- Free Chlorine During Operation: Norm 0 ppm, Max <0.1 ppm
- Chlorine During CIP at pH 10.8-11.0 and 50°C: Norm 150 ppm, Max 180 ppm
- Note: Maximum chlorine exposure for all elements is 30 minutes per day at pH and temperature conditions listed above.
Feed water
Dairy Product Total Solids Limits
(Note: Trials should be made to determine temperature and viscosity effects.)
| Feed Spacer (in mils) | 31 | 46 | 65 | 80 |
|---|---|---|---|---|
| Sweet Whey Max. T.S. | 15 | 25 | 28 | 30 |
| Acid Whey Max. T.S. | 15 | 24 | 26 | 28 |
| Skim Milk Max. T.S. | 14 | 24 | 26 | 28 |
| Whole Milk Max. T.S. | 15 | 30 | 33 | 35 |
Mechanical / Hydraulic
Element Dimensions and Weights
| Model No. | Diameter (in.) | Length (in.) | P.W.T. ID (in.) | Weight (lb) | Weight (kg) |
|---|---|---|---|---|---|
| 1812F | 1.8 | 12 | 0.63 | 1.0 | 0.5 |
| 2519 | 2.5 | 19.25 | 0.63 | 2 | 0.9 |
| 2540F | 2.5 | 40 | 0.63 | 4 | 1.8 |
| 2540M* | 2.5 | 38 | 0.75 | 4 | 1.8 |
| 3838 | 3.8 | 38 | 0.83 | 10 | 4.5 |
| 3838.75 | 3.8 | 38.75 | 0.83 | 10 | 4.5 |
| 3850 | 3.8 | 50 | 0.83 | 13 | 5.9 |
| 3938.75 | 4.0 | 38.75 | 0.63 | 10 | 4.5 |
| 4333 | 4.3 | 33 | 0.83 | 11 | 5.0 |
| 4335 | 4.3 | 35 | 0.83 | 11 | 5.2 |
| 4335.5 | 4.3 | 35.5 | 0.83 | 11 | 5.2 |
| 4336 | 4.3 | 36 | 0.83 | 11 | 5.2 |
| 4338 | 4.3 | 38 | 0.83 | 12 | 5.4 |
| 5838 | 5.8 | 38 | 1.14 | 15 | 7 |
| 6338 | 6.3 | 38 | 1.14 | 16 | 7 |
| 6324 | 6.3 | 24 | 1.14 | 17 | 7.7 |
| 6438 | 6.4 | 38 | 1.14 | 29 | 13.2 |
| 6424 | 6.4 | 24 | 1.14 | 18 | 8.2 |
| 7838 | 7.8 | 38 | 1.14 | 40 | 18.2 |
| 7824 | 7.8 | 24 | 1.14 | 26 | 11.8 |
| 8038 | 8.0 | 38 | 1.14 | 38 | 17.2 |
| 8040 | 8.0 | 40 | 1.14 | 39 | 17.7 |
| 8238 | 8.2 | 38 | 1.14 | 38 | 17.2 |
| 8240 | 8.2 | 40 | 1.14 | 40 | 18 |
| 8338 | 8.3 | 38 | 1.14 | 40 | 18 |
| 8340 | 8.3 | 40 | 1.14 | 40 | 18 |
| 9838 | 9.8 | 38 | 1.14 | 42 | 19.1 |
| 10338 | 10.3 | 38 | 1.14 | 50 | 22.7 |
*1" permeate tube extensions (0.75" OD)
Recommended Element Cross Flow Rate
(The recommended cross flow rate will be subject to differential pressure limitations and specific applications.)
| Element | Feed Spacer (in mils) | 24 | 31 | 46 | 65 | 80 |
|---|---|---|---|---|---|---|
| 1.8” | m³/hr | 1 | 1 | 1 | 2 | 2 |
| gpm | 4 | 5 | 6 | 7 | 7 | |
| 2.5” | m³/hr | 2 | 2 | 3 | 3 | 3 |
| gpm | 9 | 10 | 11 | 12 | 13 | |
| 3.8” | m³/hr | 5 | 6 | 7 | 8 | 8 |
| gpm | 22 | 25 | 29 | 33 | 35 | |
| 4.3” | m³/hr | 6 | 7 | 9 | 10 | 10 |
| gpm | 29 | 32 | 38 | 44 | 46 | |
| 5.8” | m³/hr | 12 | 13 | 16 | 18 | 19 |
| gpm | 51 | 59 | 69 | 78 | 83 | |
| 6.3” | m³/hr | 15 | 17 | 20 | 22 | 24 |
| gpm | 65 | 74 | 88 | 99 | 105 | |
| 8” | m³/hr | 21 | 24 | 29 | 33 | 35 |
| gpm | 94 | 107 | 128 | 143 | 154 | |
| 10” | m³/hr | 42 | 48 | 57 | 64 | 68 |
| gpm | 184 | 213 | 250 | 283 | 299 |
Membrane Area (sq. ft.)
| Element Model No. | Feed Spacer (in mils) | 24 | 31 | 46 | 65 | 80 |
|---|---|---|---|---|---|---|
| 1812F | N/A | 3.6 | N/A | N/A | N/A | |
| 2519 | 15 | 13 | 10 | N/A | N/A | |
| 2540F | 34 | 29 | 22 | N/A | N/A | |
| 2540M | 35 | 30 | 23 | N/A | N/A | |
| 3838 | 85 | 72 | 58 | 46 | 38 | |
| 3838.75 | 86 | 74 | 59 | 47 | 39 | |
| 3850 | 100 | 84 | 70 | 52 | 46 | |
| 3938.75 | 102 | 89 | 69 | 53 | 47 | |
| 4333 | 99 | 86 | 66 | 53 | 44 | |
| 4335 | 105 | 91 | 71 | 56 | 47 | |
| 4335.5 | 107 | 93 | 72 | 57 | 48 | |
| 4336 | 108 | 94 | 73 | 58 | 49 | |
| 4338 | 115 | 100 | 77 | 62 | 52 | |
| 5838 | 210 | 184 | 147 | 114 | 96 | |
| 6324 | 150 | 134 | 107 | 83 | 70 | |
| 6338 | 246 | 220 | 176 | 136 | 115 | |
| 6424 | 157 | 140 | 112 | 83 | 74 | |
| 6438 | 258 | 230 | 184 | 136 | 122 | |
| 7824 | 242 | 210 | 166 | 132 | 110 | |
| 7838 | 396 | 344 | 273 | 216 | 180 | |
| 8038 | 414 | 368 | 287 | 225 | 189 | |
| 8040 | 414 | 368 | 287 | 225 | 189 | |
| 8238 | 441 | 384 | 302 | 238 | 201 | |
| 8240 | 441 | 384 | 302 | 238 | 201 | |
| 8338 | 450 | 400 | 311 | 245 | 207 | |
| 8340 | 450 | 400 | 311 | 245 | 207 | |
| 9838 | N/A | 564 | 440 | 351 | 296 | |
| 10338 | N/A | 620 | 492 | 386 | 326 |