Back to Synder Membranes
Synder logo

Datasheet summary

FR PVDF 800kDa

Engineering summary from PDF text extraction for FR PVDF 800kDa. Verify every value with the OEM datasheet.

Summary

Product Identification

Synder Filtration's FR (PVDF 800kDa) Microfiltration elements are sanitary spiral-wound elements designed for optimal flux and rejection.

Operating Limits

  • Maximum Temperature: 55°C (131°F)
  • pH Range @ Maximum Temperature: 3-9
  • pH Range @ Ambient Temperature: 2-10

Pressure

  • Max Inlet Pressure: 120 PSI (8.3 Bar)
  • Min Outlet Pressure: 10 PSI (0.7 Bar)
  • Max Differential Pressure per Element: 18 PSI (1.2 Bar)
  • Max Permeate Backpressure: 5 PSI (0.3 Bar)
  • Note: Soft start on boost pumps required to minimize pressure/flow shocks to elements.

Cleaning Parameters

  • Maximum Temperature (Short term <30min): 50°C (122°F)
  • pH Range @ Maximum Temperature: 2-11
  • pH Range @ Ambient Temperature: 1.8-11

Chlorine

  • Free Chlorine During Operation:
    • Norm ppm: 0
    • Max ppm: <0.1
  • Chlorine During CIP at pH10.8-11.0 and 50°C:
    • Norm ppm: 150
    • Max ppm: 180
  • Note: Maximum chlorine exposure for all elements is 30 minutes per day at pH and temperature conditions listed above.

Feed Water

Dairy Product Total Solids Limits

Feed Spacer (in mils)31466580
Sweet Whey Max. T.S.15252830
Acid Whey Max. T.S.15242628
Skim Milk Max. T.S.14242628
Whole Milk Max. T.S.15303335
  • Note: Trials should be made to determine temperature and viscosity effects.

Mechanical / Hydraulic

Element Dimensions & Weights

Model No.OD (in.)L (in.)ID* (in.)Weight (lb)Weight (kg)
1812F1.8120.631.00.5
25192.519.250.6320.9
2540F2.5400.6341.8
2540M*2.5380.7541.8
38383.8380.83104.5
3838.753.838.750.83104.5
38503.8500.83135.9
3938.754.038.750.63104.5
43334.3330.83115.0
43354.3350.83115.2
4335.54.335.50.83115.2
43364.3360.83115.2
43384.3380.83125.4
58385.8381.14157
63386.3381.14167
63246.3241.14177.7
64386.4381.142913.2
64246.4241.14188.2
78387.8381.144018.2
78247.8241.142611.8
80388.0381.143817.2
80408.0401.143917.7
82388.2381.143817.2
82408.2401.144018
83388.3381.144018
83408.3401.144018
98389.8381.144219.1
1033810.3381.145022.7

*1” permeate tube extensions (0.75” OD) Note: Different diameters are available. Specifications are subject to change without notice.

Membrane Area (sq. ft.)

Element Model No.Feed Spacer (in mils)2431466580
1.8” 1812FN/A3.6N/AN/AN/A
2.5” 2519151310N/AN/A
2.5” 2540F342922N/AN/A
2.5” 2540M353023N/AN/A
3.8” 38388572584638
3.8” 3838.758674594739
3.8” 385010084705246
3.8” 3938.7510289695347
4.3” 43339986665344
4.3” 433510591715647
4.3” 4335.510793725748
4.3” 433610894735849
4.3” 4338115100776252
5.8” 583821018414711496
6.3” 63241501341078370
6.3” 6338246220176136115
6.4” 64241571401128374
6.4” 6438258230184136122
7.8” 7824242210166132110
7.8” 7838396344273216180
8” 8038414368287225189
8” 8040414368287225189
8.2” 8238441384302238201
8.2” 8240441384302238201
8.3” 8338450400311245207
8.3” 8340450400311245207
9.8” 9838N/A564440351296
10” 10338N/A620492386326

Recommended Element Cross Flow Rate

ElementFeed Spacer (in mils)2431466580
1.8”m³/hr11122
gpm45677
2.5”m³/hr22333
gpm910111213
3.8”m³/hr56788
gpm2225293335
4.3”m³/hr6791010
gpm2932384446
5.8”m³/hr1213161819
gpm5159697883
6.3”m³/hr1517202224
gpm65748899105
8”m³/hr2124293335
gpm94107128143154
10”m³/hr4248576468
gpm184213250283299
  • The recommended cross flow rate will be subject to differential pressure limitations and specific applications.

Benefits

  • Conforms to 3-A, FDA, and USDA sanitary standards
  • Good resistance to pH and temperature
  • High resistance to fouling
  • Customizable dimensions for unique housings

Applications

  • Fat/Microbial removal
  • Protein fractionation

Disclaimer: This summary is based on extracted text and may omit figures, footnotes, or the most recent revisions. For contractual data, always refer to the specific OEM PDF revision used on your project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.