Back to Synder Membranes
Synder logo

Datasheet summary

LV PES 200kDa

Engineering summary from PDF text extraction for LV PES 200kDa. Verify every value with the OEM datasheet.

Summary

Product identification

Sanitary Ultrafiltration Spiral-Wound Element: LV (PES 200kDa)

Synder Filtration’s Ultrafiltration Elements offer an optimal combination of both flux and rejection in a comprehensive range of MWCO’s.

Operating limits

  • Maximum Temperature: 55°C (131°F)
  • pH Range @ Max Temperature: 3-9
  • pH Range @ Ambient Temperature: 2-10

Pressure

  • Max Inlet Pressure: 120 PSI (8.3 Bar)
  • Min Outlet Pressure: 10 PSI (0.7 Bar)
  • Max Differential Pressure per Element: 18 PSI (1.2 Bar)
  • Max Permeate Backpressure: 5 PSI (0.3 Bar)

Note: Soft start on boost pumps required to minimize pressure/flow shocks to elements.

Cleaning parameters

  • Maximum Temperature (Short term <30min): 50°C (122°F)
  • pH Range @ Max Temperature: 2-11
  • pH Range @ Ambient Temperature: 1.8-11

Chlorine

  • Free Chlorine During Operation: 0 Norm ppm (<0.1 Max ppm)
  • Chlorine During CIP at pH10.8-11.0 and 50°C: 150 Norm ppm (180 Max ppm)

Note: Maximum chlorine exposure for all elements is 30 minutes per day at pH and temperature conditions listed above.

Feed water

Dairy Product Total Solids Limits

Feed Spacer (in mils)31466580
Sweet Whey Max. T.S.15252830
Acid Whey Max. T.S.15242628
Skim Milk Max. T.S.14242628
Whole Milk Max. T.S.15303335

Note: Trials should be made to determine temperature and viscosity effects.

Mechanical / hydraulic

Element Dimensions and Weights

Model No.OD (in.)L (in.)ID* (in.)Weight (lb)Weight (kg)
1812F1.8120.631.00.5
25192.519.250.6320.9
2540F2.5400.6341.8
2540M*2.5380.7541.8
38383.8380.83104.5
3838.753.838.750.83104.5
38503.8500.83135.9
3938.754.038.750.63104.5
43334.3330.83115.0
43354.3350.83115.2
4335.54.335.50.83115.2
43364.3360.83115.2
43384.3380.83125.4
58385.8381.14157
63386.3381.14167
63246.3241.14177.7
64386.4381.142913.2
64246.4241.14188.2
78387.8381.144018.2
78247.8241.142611.8
80388.0381.143817.2
80408.0401.143917.7
82388.2381.143817.2
82408.2401.144018
83388.3381.144018
83408.3401.144018
98389.8381.144219.1
1033810.3381.145022.7

*Note: 1” permeate tube extensions (0.75” OD)

Membrane Area (SQ. FT.)

ElementModel No.Feed Spacer (in mils) 24Feed Spacer (in mils) 31Feed Spacer (in mils) 46Feed Spacer (in mils) 65Feed Spacer (in mils) 80
1.8”
1812FN/A3.6N/AN/AN/A
2.5”
2519151310N/AN/A
2540F342922N/AN/A
2540M353023N/AN/A
3.8”
38388572584638
3838.758674594739
385010084705246
3938.7510289695347
4.3”
43339986665344
433510591715647
4335.510793725748
433610894735849
4338115100776252
5.8”
583821018414711496
6.3”
63241501341078370
6338246220176136115
6.4”
64241571401128374
6438258230184136122
7.8”
7824242210166132110
7838396344273216180
8”
8038414368287225189
8040414368287225189
8238441384302238201
8240441384302238201
8338450400311245207
8340450400311245207
9.8”
9838N/A564440351296
10”
10338N/A620492386326

Recommended Element Cross Flow Rate

ElementFeed Spacer (in mils)m³/hrgpm
1.8”2414
3115
4616
6527
8027
2.5”2429
31210
46311
65312
80313
3.8”24522
31625
46729
65833
80835
4.3”24629
31732
46938
651044
801046
5.8”241251
311359
461669
651878
801983
6.3”241565
311774
462088
652299
8024105
8”242194
3124107
4629128
6533143
8035154
10”2442184
3148213
4657250
6564283
8068299

Note: The recommended cross flow rate will be subject to differential pressure limitations and specific applications. Please consult Synder Filtration if additional information is needed.

Standard Series Benefits

  • Conforms to 3-A, FDA, and USDA sanitary standards
  • Widest range of UF MWCO’s available
  • Good resistance to pH and temperature
  • High resistance to fouling
  • Customizable dimensions for unique housings

Common Applications

  • Corn wet milling

Disclaimer: This summary is generated from extracted text and may not include all figures, footnotes, or the latest revisions. For contractual data, always refer to the official OEM PDF revision used on your project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.