Datasheet summary
LV PHT PES 200kDa
Engineering summary from PDF text extraction for LV PHT PES 200kDa. Verify every value with the OEM datasheet.
Summary
Product Identification
Synder Filtration’s PHT Series of Ultrafiltration Elements offer exceptional physical and chemical durability.
PHT Series Benefits:
- Conforms to 3-A, FDA, and USDA sanitary standards
- Elimination of chlorine during CIP with hot sanitation
- High resistance to pH, temperature, & fouling
- Customizable dimensions for unique housings
Operating Limits
Recommended Operating Parameters
- Maximum Temperature: 60°C (140°F)
- pH Range @ Max Temperature: 2-10
- pH Range @ Ambient Temperature: 2-10.5
Pressure
- Max Inlet Pressure: 120 PSI (8.3 Bar)
- Min Outlet Pressure: 10 PSI (0.7 Bar)
- Max Differential Pressure per Element: 18 PSI (1.2 Bar)
- Max Permeate Backpressure: 5 PSI (0.3 Bar)
- Note: Soft start on boost pumps required to minimize pressure/flow shocks to elements.
Cleaning Parameters
- Maximum Temperature (Short term <30min): 85°C (185°F)
- pH Range @ Max Temperature: 2-11
- pH Range @ Ambient Temperature: 2-12.5
Chlorine
- Free Chlorine During Operation: Norm 0 ppm, Max <0.1 ppm
- Chlorine During CIP at pH 10.8-11.0 and 50°C: Norm 150 ppm, Max 180 ppm
- Note: Maximum chlorine exposure for all elements is 30 minutes per day at pH and temperature conditions listed above.
Dairy Product Total Solids Limits
| Feed Spacer (in mils) | 31 | 46 | 65 | 80 |
|---|---|---|---|---|
| Sweet Whey Max. T.S. | 15 | 25 | 28 | 30 |
| Acid Whey Max. T.S. | 15 | 24 | 26 | 28 |
| Skim Milk Max. T.S. | 14 | 24 | 26 | 28 |
| Whole Milk Max. T.S. | 15 | 30 | 33 | 35 |
Note: Trials should be made to determine temperature and viscosity effects.
Common Applications
- Corn wet milling
Mechanical / Hydraulic
Element Dimensions
| Element Model No. | Diameter (B) in | Length (A) in | P.W.T. ID |
|---|---|---|---|
| 1812F | 1.8 | 12 | 0.63 |
| 2519 | 2.5 | 19.25 | 0.63 |
| 2540F | 2.5 | 40 | 0.63 |
| 2540M* | 2.5 | 38 | 0.75 |
| 3838 | 3.8 | 38 | 0.83 |
| 3838.75 | 3.8 | 38.75 | 0.83 |
| 3850 | 3.8 | 50 | 0.83 |
| 3938.75 | 4.0 | 38.75 | 0.63 |
| 4333 | 4.3 | 33 | 0.83 |
| 4335 | 4.3 | 35 | 0.83 |
| 4335.5 | 4.3 | 35.5 | 0.83 |
| 4336 | 4.3 | 36 | 0.83 |
| 4338 | 4.3 | 38 | 0.83 |
| 5838 | 5.8 | 38 | 1.14 |
| 6338 | 6.3 | 38 | 1.14 |
| 6324 | 6.3 | 24 | 1.14 |
| 6438 | 6.4 | 38 | 1.14 |
| 6424 | 6.4 | 24 | 1.14 |
| 7838 | 7.8 | 38 | 1.14 |
| 7824 | 7.8 | 24 | 1.14 |
| 8038 | 8.0 | 38 | 1.14 |
| 8040 | 8.0 | 40 | 1.14 |
| 8238 | 8.2 | 38 | 1.14 |
| 8240 | 8.2 | 40 | 1.14 |
| 8338 | 8.3 | 38 | 1.14 |
| 8340 | 8.3 | 40 | 1.14 |
| 9838 | 9.8 | 38 | 1.14 |
| 10338 | 10.3 | 38 | 1.14 |
| Note: *1” permeate tube extensions (0.75” OD) |
Element Descriptions
| Model No. | OD (in.) | L (in.) | ID* (in.) | Weight (lb) | Weight (kg) |
|---|---|---|---|---|---|
| 1812F | 1.8 | 12 | 0.63 | 1.0 | 0.5 |
| 2519 | 2.5 | 19.25 | 0.63 | 2 | 0.9 |
| 2540F | 2.5 | 40 | 0.63 | 4 | 1.8 |
| 2540M* | 2.5 | 38 | 0.75 | 4 | 1.8 |
| 3838 | 3.8 | 38 | 0.83 | 10 | 4.5 |
| 3838.75 | 3.8 | 38.75 | 0.83 | 10 | 4.5 |
| 3850 | 3.8 | 50 | 0.83 | 13 | 5.9 |
| 3938.75 | 4.0 | 38.75 | 0.63 | 10 | 4.5 |
| 4333 | 4.3 | 33 | 0.83 | 11 | 5.0 |
| 4335 | 4.3 | 35 | 0.83 | 11 | 5.2 |
| 4335.5 | 4.3 | 35.5 | 0.83 | 11 | 5.2 |
| 4336 | 4.3 | 36 | 0.83 | 11 | 5.2 |
| 4338 | 4.3 | 38 | 0.83 | 12 | 5.4 |
| 5838 | 5.8 | 38 | 1.14 | 15 | 7 |
| 6338 | 6.3 | 38 | 1.14 | 16 | 7 |
| 6324 | 6.3 | 24 | 1.14 | 17 | 7.7 |
| 6438 | 6.4 | 38 | 1.14 | 29 | 13.2 |
| 6424 | 6.4 | 24 | 1.14 | 18 | 8.2 |
| 7838 | 7.8 | 38 | 1.14 | 40 | 18.2 |
| 7824 | 7.8 | 24 | 1.14 | 26 | 11.8 |
| 8038 | 8.0 | 38 | 1.14 | 38 | 17.2 |
| 8040 | 8.0 | 40 | 1.14 | 39 | 17.7 |
| 8238 | 8.2 | 38 | 1.14 | 38 | 17.2 |
| 8240 | 8.2 | 40 | 1.14 | 40 | 18 |
| 8338 | 8.3 | 38 | 1.14 | 40 | 18 |
| 8340 | 8.3 | 40 | 1.14 | 40 | 18 |
| 9838 | 9.8 | 38 | 1.14 | 42 | 19.1 |
| 10338 | 10.3 | 38 | 1.14 | 50 | 22.7 |
| Note: *1” permeate tube extensions (0.75” OD) |
Recommended Element Cross Flow Rate
| Element | Unit | 24 mils | 31 mils | 46 mils | 65 mils | 80 mils |
|---|---|---|---|---|---|---|
| 1.8” | m³/hr | 1 | 1 | 1 | 2 | 2 |
| gpm | 4 | 5 | 6 | 7 | 7 | |
| 2.5” | m³/hr | 2 | 2 | 3 | 3 | 3 |
| gpm | 9 | 10 | 11 | 12 | 13 | |
| 3.8” | m³/hr | 5 | 6 | 7 | 8 | 8 |
| gpm | 22 | 25 | 29 | 33 | 35 | |
| 4.3” | m³/hr | 6 | 7 | 9 | 10 | 10 |
| gpm | 29 | 32 | 38 | 44 | 46 | |
| 5.8” | m³/hr | 12 | 13 | 16 | 18 | 19 |
| gpm | 51 | 59 | 69 | 78 | 83 | |
| 6.3” | m³/hr | 15 | 17 | 20 | 22 | 24 |
| gpm | 65 | 74 | 88 | 99 | 105 | |
| 8” | m³/hr | 21 | 24 | 29 | 33 | 35 |
| gpm | 94 | 107 | 128 | 143 | 154 | |
| 10” | m³/hr | 42 | 48 | 57 | 64 | 68 |
| gpm | 184 | 213 | 250 | 283 | 299 |
Note: The recommended cross flow rate will be subject to differential pressure limitations and specific applications. Please consult Synder Filtration if additional information is needed.
Membrane Area (sq. ft.)
| Element Model No. | Feed Spacer (in mils) | ||||
|---|---|---|---|---|---|
| 24 | 31 | 46 | 65 | 80 | |
| 1812F | N/A | 3.6 | N/A | N/A | N/A |
| 2519 | 15 | 13 | 10 | N/A | N/A |
| 2540F | 34 | 29 | 22 | N/A | N/A |
| 2540M | 35 | 30 | 23 | N/A | N/A |
| 3838 | 85 | 72 | 58 | 46 | 38 |
| 3838.75 | 86 | 74 | 59 | 47 | 39 |
| 3850 | 100 | 84 | 70 | 52 | 46 |
| 3938.75 | 102 | 89 | 69 | 53 | 47 |
| 4333 | 99 | 86 | 66 | 53 | 44 |
| 4335 | 105 | 91 | 71 | 56 | 47 |
| 4335.5 | 107 | 93 | 72 | 57 | 48 |
| 4336 | 108 | 94 | 73 | 58 | 49 |
| 4338 | 115 | 100 | 77 | 62 | 52 |
| 5838 | 210 | 184 | 147 | 114 | 96 |
| 6324 | 150 | 134 | 107 | 83 | 70 |
| 6338 | 246 | 220 | 176 | 136 | 115 |
| 6424 | 157 | 140 | 112 | 83 | 74 |
| 6438 | 258 | 230 | 184 | 136 | 122 |
| 7824 | 242 | 210 | 166 | 132 | 110 |
| 7838 | 396 | 344 | 273 | 216 | 180 |
| 8038 | 414 | 368 | 287 | 225 | 189 |
| 8040 | 414 | 368 | 287 | 225 | 189 |
| 8238 | 441 | 384 | 302 | 238 | 201 |
| 8240 | 441 | 384 | 302 | 238 | 201 |
| 8338 | 450 | 400 | 311 | 245 | 207 |
| 8340 | 450 | 400 | 311 | 245 | 207 |
| 9838 | N/A | 564 | 440 | 351 | 296 |
| 10338 | N/A | 620 | 492 | 386 | 326 |
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. For contractual data, please refer to the specific OEM PDF revision used on your project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.