Back to Synder Membranes
Synder logo

Datasheet summary

LX PES 300kDa

Engineering summary from PDF text extraction for LX PES 300kDa. Verify every value with the OEM datasheet.

Summary

Product identification

Synder Filtration's Sanitary Ultrafiltration Spiral-Wound Element: LX (PES 300kDa) offers an optimal combination of flux and rejection.

Standard Series Benefits:

  • Conforms to 3-A, FDA, and USDA sanitary standards
  • Widest range of UF MWCOs available
  • Good resistance to pH and temperature
  • High resistance to fouling
  • Customizable dimensions for unique housings

Common Applications:

  • Corn wet milling

Operating limits

  • Maximum Temperature: 55°C (131°F)
  • pH Range @ Max Temperature: 3-9
  • pH Range @ Ambient Temperature: 2-10

Pressure:

  • Max Inlet Pressure: 120 PSI (8.3 Bar)
  • Min Outlet Pressure: 10 PSI (0.7 Bar)
  • Max Differential Pressure per Element: 18 PSI (1.2 Bar)
  • Max Permeate Backpressure: 5 PSI (0.3 Bar)
  • Note: Soft start on boost pumps required to minimize pressure/flow shocks to elements.

Cleaning Parameters

  • Maximum Temperature (Short term <30min): 50°C (122°F)
  • pH Range @ Max Temperature: 2-11
  • pH Range @ Ambient Temperature: 1.8-11

Chlorine:

  • Free Chlorine During Operation: 0 Norm ppm, <0.1 Max ppm
  • Chlorine During CIP at pH10.8-11.0 and 50°C: 150 Norm ppm, 180 Max ppm
  • Note: Maximum chlorine exposure for all elements is 30 minutes per day at pH and temperature conditions listed above.

Feed water

Dairy Product Total Solids Limits:

Feed Spacer (in mils)31466580
Sweet Whey Max. T.S.15252830
Acid Whey Max. T.S.15242628
Skim Milk Max. T.S.14242628
Whole Milk Max. T.S.15303335
Note: Trials should be made to determine temperature and viscosity effects.

Mechanical / hydraulic

Element Dimensions:

Element Model No.Diameter (B) inLength (A) inP.W.T. ID
1.8”
1812F1.8120.63
2.5”
25192.519.250.63
2540F2.5400.63
2540M*2.5380.75
3.8”
38383.8380.83
3838.753.838.750.83
38503.8500.83
3938.754.038.750.63
4.3”
43334.3330.83
43354.3350.83
4335.54.335.50.83
43364.3360.83
43384.3380.83
5.8”
58385.8381.14
6.3”
63386.3381.14
63246.3241.14
6.4”
64386.4381.14
64246.4241.14
7.8”
78387.8381.14
78247.8241.14
8”
80388.0381.14
80408.0401.14
82388.2381.14
82408.2401.14
83388.3381.14
83408.3401.14
9.8”
98389.8381.14
10”
1033810.3381.14
*1” permeate tube extensions (0.75” OD)

Membrane Area (sq. ft.):

Element Model No.2431466580
1.8”
1812FN/A3.6N/AN/AN/A
2.5”
2519151310N/AN/A
2540F342922N/AN/A
2540M353023N/AN/A
3.8”
38388572584638
3838.758674594739
385010084705246
3938.7510289695347
4.3”
43339986665344
433510591715647
4335.510793725748
433610894735849
4338115100776252
5.8”
583821018414711496
6.3”
63241501341078370
6338246220176136115
6.4”
64241571401128374
6438258230184136122
7.8”
7824242210166132110
7838396344273216180
8”
8038414368287225189
8040414368287225189
8238441384302238201
8240441384302238201
8338450400311245207
8340450400311245207
9.8”
9838N/A564440351296
10”
10338N/A620492386326

Recommended Element Cross Flow Rate:

ElementFeed Spacer (in mils)2431466580
1.8”m³/hr11122
gpm45677
2.5”m³/hr22333
gpm910111213
3.8”m³/hr56788
gpm2225293335
4.3”m³/hr6791010
gpm2932384446
5.8”m³/hr1213161819
gpm5159697883
6.3”m³/hr1517202224
gpm65748899105
8”m³/hr2124293335
gpm94107128143154
10”m³/hr4248576468
gpm184213250283299
The recommended cross flow rate will be subject to differential pressure limitations and specific applications. Please consult Synder Filtration if additional information is needed.

Element Descriptions:

Model No.OD (in.)L (in.)ID* (in.)Weight (lb)Weight (kg)
1812F1.8120.631.00.5
25192.519.250.6320.9
2540F2.5400.6341.8
2540M*2.5380.7541.8
38383.8380.83104.5
3838.753.838.750.83104.5
38503.8500.83135.9
3938.754.038.750.63104.5
43334.3330.83115.0
43354.3350.83115.2
4335.54.335.50.83115.2
43364.3360.83115.2
43384.3380.83125.4
58385.8381.14157
63386.3381.14167
63246.3241.14177.7
64386.4381.142913.2
64246.4241.14188.2
78387.8381.144018.2
78247.8241.142611.8
80388.0381.143817.2
80408.0401.143917.7
82388.2381.143817.2
82408.2401.144018
83388.3381.144018
83408.3401.144018
98389.8381.144219.1
1033810.3381.145022.7
*1” permeate tube extensions (0.75” OD)
Note: Different diameters are available. Please specify your requirements when ordering.

Technical Notes: For element sizes not listed, contact Synder Filtration for details. Elements can be designed to fit specific needs by specifying the element outer diameter (OD) or vessel/housing inner diameter (ID), element inner diameter (ID), and length. Elements are also available with or without a controlled bypass tail. Additional feed spacers are available. Trials should be conducted to determine optimal application conditions.


Disclaimer: This summary is based on the provided text extraction and may not include all figures, footnotes, or the latest revisions found in the official PDF datasheet. For contractual data or complete specifications, please refer to the OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.