Summary
Product identification
- Product Type: Sanitary Ultrafiltration Spiral-Wound Element
- Model Name: LY (PES 100kDa)
- Membrane Material: PES (Polyethersulfone)
- Molecular Weight Cut-Off (MWCO): 100 kDa
- General Features: Synder Filtration’s Ultrafiltration Elements offer an optimal combination of both flux and rejection in a comprehensive range of MWCO’s.
Operating limits
- Maximum Temperature: 55°C (131°F)
- pH Range @ Max Temperature: 3-9
- pH Range @ Ambient Temperature: 2-10
- Max Inlet Pressure: 120 PSI (8.3 Bar)
- Min Outlet Pressure: 10 PSI (0.7 Bar)
- Max Differential Pressure per Element: 18 PSI (1.2 Bar)
- Max Permeate Backpressure: 5 PSI (0.3 Bar)
- Note: Soft start on boost pumps is required to minimize pressure/flow shocks to elements.
Cleaning Parameters
- Maximum Temperature (Short term <30min): 50°C (122°F)
- pH Range @ Max Temperature: 2-11
- pH Range @ Ambient Temperature: 1.8-11
- Chlorine Exposure:
- Free Chlorine During Operation: 0 Norm ppm, <0.1 Max ppm
- Chlorine During CIP at pH10.8-11.0 and 50°C: 150 Norm ppm, 180 Max ppm
- Note: Maximum chlorine exposure for all elements is 30 minutes per day at the listed pH and temperature conditions.
Feed water
- Dairy Product Total Solids (T.S.) Limits:
| Feed Spacer (in mils) | 31 | 46 | 65 | 80 |
|---|---|---|---|---|
| Sweet Whey Max. T.S. | 15 | 25 | 28 | 30 |
| Acid Whey Max. T.S. | 15 | 24 | 26 | 28 |
| Skim Milk Max. T.S. | 14 | 24 | 26 | 28 |
| Whole Milk Max. T.S. | 15 | 30 | 33 | 35 |
- Note: Trials should be made to determine temperature and viscosity effects.
Mechanical / hydraulic
- Element Dimensions:
| Element Model No. | Diameter (B) in | Length (A) in | P.W.T. ID in |
|---|---|---|---|
| 1812F | 1.8 | 12 | 0.63 |
| 2519 | 2.5 | 19.25 | 0.63 |
| 2540F | 2.5 | 40 | 0.63 |
| 2540M* | 2.5 | 38 | 0.75 |
| 3838 | 3.8 | 38 | 0.83 |
| 3838.75 | 3.8 | 38.75 | 0.83 |
| 3850 | 3.8 | 50 | 0.83 |
| 3938.75 | 4.0 | 38.75 | 0.63 |
| 4333 | 4.3 | 33 | 0.83 |
| 4335 | 4.3 | 35 | 0.83 |
| 4335.5 | 4.3 | 35.5 | 0.83 |
| 4336 | 4.3 | 36 | 0.83 |
| 4338 | 4.3 | 38 | 0.83 |
| 5838 | 5.8 | 38 | 1.14 |
| 6338 | 6.3 | 38 | 1.14 |
| 6324 | 6.3 | 24 | 1.14 |
| 6438 | 6.4 | 38 | 1.14 |
| 6424 | 6.4 | 24 | 1.14 |
| 7838 | 7.8 | 38 | 1.14 |
| 7824 | 7.8 | 24 | 1.14 |
| 8038 | 8.0 | 38 | 1.14 |
| 8040 | 8.0 | 40 | 1.14 |
| 8238 | 8.2 | 38 | 1.14 |
| 8240 | 8.2 | 40 | 1.14 |
| 8338 | 8.3 | 38 | 1.14 |
| 8340 | 8.3 | 40 | 1.14 |
| 9838 | 9.8 | 38 | 1.14 |
| 10338 | 10.3 | 38 | 1.14 |
| *1” permeate tube extensions (0.75” OD) |
- Membrane Area (sq. ft.) by Feed Spacer (in mils):
| Element Model No. | 24 | 31 | 46 | 65 | 80 |
|---|---|---|---|---|---|
| 1812F | N/A | 3.6 | N/A | N/A | N/A |
| 2519 | 15 | 13 | 10 | N/A | N/A |
| 2540F | 34 | 29 | 22 | N/A | N/A |
| 2540M | 35 | 30 | 23 | N/A | N/A |
| 3838 | 85 | 72 | 58 | 46 | 38 |
| 3838.75 | 86 | 74 | 59 | 47 | 39 |
| 3850 | 100 | 84 | 70 | 52 | 46 |
| 3938.75 | 102 | 89 | 69 | 53 | 47 |
| 4333 | 99 | 86 | 66 | 53 | 44 |
| 4335 | 105 | 91 | 71 | 56 | 47 |
| 4335.5 | 107 | 93 | 72 | 57 | 48 |
| 4336 | 108 | 94 | 73 | 58 | 49 |
| 4338 | 115 | 100 | 77 | 62 | 52 |
| 5838 | 210 | 184 | 147 | 114 | 96 |
| 6324 | 150 | 134 | 107 | 83 | 70 |
| 6338 | 246 | 220 | 176 | 136 | 115 |
| 6424 | 157 | 140 | 112 | 83 | 74 |
| 6438 | 258 | 230 | 184 | 136 | 122 |
| 7824 | 242 | 210 | 166 | 132 | 110 |
| 7838 | 396 | 344 | 273 | 216 | 180 |
| 8038 | 414 | 368 | 287 | 225 | 189 |
| 8040 | 414 | 368 | 287 | 225 | 189 |
| 8238 | 441 | 384 | 302 | 238 | 201 |
| 8240 | 441 | 384 | 302 | 238 | 201 |
| 8338 | 450 | 400 | 311 | 245 | 207 |
| 8340 | 450 | 400 | 311 | 245 | 207 |
| 9838 | N/A | 564 | 440 | 351 | 296 |
| 10338 | N/A | 620 | 492 | 386 | 326 |
-
Recommended Element Cross Flow Rate: The datasheet provides a table of recommended cross flow rates in m³/hr and gpm for various element sizes (1.8" to 10") across different feed spacer configurations (24, 31, 46, 65, 80 mils). See the official PDF for exact tabulated values. The recommended cross flow rate is subject to differential pressure limitations and specific applications.
-
Element Descriptions (Weight):
| Model No. | OD (in.) | L (in.) | ID* (in.) | Weight (lb) | Weight (kg) |
|---|---|---|---|---|---|
| 1812F | 1.8 | 12 | 0.63 | 1.0 | 0.5 |
| 2519 | 2.5 | 19.25 | 0.63 | 2 | 0.9 |
| 2540F | 2.5 | 40 | 0.63 | 4 | 1.8 |
| 2540M* | 2.5 | 38 | 0.75 | 4 | 1.8 |
| 3838 | 3.8 | 38 | 0.83 | 10 | 4.5 |
| 3838.75 | 3.8 | 38.75 | 0.83 | 10 | 4.5 |
| 3850 | 3.8 | 50 | 0.83 | 13 | 5.9 |
| 3938.75 | 4.0 | 38.75 | 0.63 | 10 | 4.5 |
| 4333 | 4.3 | 33 | 0.83 | 11 | 5.0 |
| 4335 | 4.3 | 35 | 0.83 | 11 | 5.2 |
| 4335.5 | 4.3 | 35.5 | 0.83 | 11 | 5.2 |
| 4336 | 4.3 | 36 | 0.83 | 11 | 5.2 |
| 4338 | 4.3 | 38 | 0.83 | 12 | 5.4 |
| 5838 | 5.8 | 38 | 1.14 | 15 | 7 |
| 6338 | 6.3 | 38 | 1.14 | 16 | 7 |
| 6324 | 6.3 | 24 | 1.14 | 17 | 7.7 |
| 6438 | 6.4 | 38 | 1.14 | 29 | 13.2 |
| 6424 | 6.4 | 24 | 1.14 | 18 | 8.2 |
| 7838 | 7.8 | 38 | 1.14 | 40 | 18.2 |
| 7824 | 7.8 | 24 | 1.14 | 26 | 11.8 |
| 8038 | 8.0 | 38 | 1.14 | 38 | 17.2 |
| 8040 | 8.0 | 40 | 1.14 | 39 | 17.7 |
| 8238 | 8.2 | 38 | 1.14 | 38 | 17.2 |
| 8240 | 8.2 | 40 | 1.14 | 40 | 18 |
| 8338 | 8.3 | 38 | 1.14 | 40 | 18 |
| 8340 | 8.3 | 40 | 1.14 | 40 | 18 |
| 9838 | 9.8 | 38 | 1.14 | 42 | 19.1 |
| 10338 | 10.3 | 38 | 1.14 | 50 | 22.7 |
| *1” permeate tube extensions (0.75” OD) |
- Customization: Different diameters are available. Elements can be designed to fit specific outer diameter (OD) or vessel/housing inner diameter (ID), element inner diameter (ID), and length. Elements are also available with or without a controlled bypass tail. Additional feed spacers are available.
Standard Series Benefits
- Conforms to 3-A, FDA, and USDA sanitary standards
- Widest range of UF MWCO’s available
- Good resistance to pH and temperature
- High resistance to fouling
- Customizable dimensions for unique housings