Back to Synder Membranes
Synder logo

Datasheet summary

NFG TFC 600-800Da

Engineering summary from PDF text extraction for NFG TFC 600-800Da. Verify every value with the OEM datasheet.

Summary

Product identification

This document describes the NFG (600-800Da) Sanitary Nanofiltration Spiral-Wound Element. Synder Filtration’s Nanofiltration membranes are engineered to provide superior separation performance for various application needs. Known for stable flux and a wide range of rejection to monovalent and divalent ions, these NF membranes are developed specifically for specialty process applications.

NF Series Benefits

  • Competitive flux as the current industry standard NF membranes
  • Excellent MgSO₄ and lactose rejection
  • Operate at lower pressures than Reverse Osmosis membranes and still achieve excellent rejection of divalent and multivalent ions
  • NF membranes greatly reduce levels of hardness, nitrates, sulfates, tannins, turbidity, color, TDS, and moderate levels of salt from feed water streams

Operating limits

Recommended Operating Parameters

  • Maximum Operating Pressure:
    • 600 psi (4,137 kPa) if T < 95°F (35°C)
    • 435 psi (3,000 kPa) if T > 95°F (35°C)
  • Maximum Temperature: 50°C (122°F)
  • pH Range @ Max Temperature: 4-9
  • pH Range @ Ambient Temperature: 4-10

Cleaning Parameters

  • Maximum Temperature (Short term < 30 min): 40°C (104°F)
  • pH Range @ Max Temperature: 3-10
  • pH Range @ Ambient Temperature: 3-10.5

Pressure Drop

  • Maximum per Element: 15 psi (103 kPa)
  • Maximum per Housing: 60 psi (414 kPa)

Chlorine Tolerance

  • 500 ppm hours, dechlorination recommended

Common applications

  • Demineralization & concentration of lactose
  • Desalination of dyes and optical brighteners
  • Seawater sulfate removal

Membrane Specifications

  • Model: NFG
  • Polymer: Proprietary PA TFC
  • Approx. Molecular Weight Cutoff: 600-800 Da
  • Typical Operating Flux: 55-60 GFD
  • Min Lactose Rejection¹: 60.0%
  • Min MgSO₄ Rejection²: 50.0%
  • Average NaCl Rejection³: 10.0%

¹Test Conditions: 2% Lactose solution at 110 psi (760 kPa) operating pressure, 77°F (25°C) ²Test Conditions: 2,000 ppm MgSO₄ solution at 110 psi (760 kPa) operating pressure, 77°F (25°C) ³Test Conditions: 2,000 ppm NaCl solution at 110 psi (760 kPa) operating pressure, 77°F (25°C)

Mechanical / hydraulic

Element Dimensions & Weight

Element Model NumberDiameter (B) in (cm)Length (A) in (cm)PWT ID/OD in (cm)Tube Extension (C) in (cm)Dry Weight lb (kg)
1.8”
1812F1.8 (4.6)12.0 (30.5)0.63 (1.6)-1.0 (0.5)
2.5”
2540F2.4 (6.1)40.0 (101.6)0.63 (1.6)-4.0 (1.8)
2540M2.4 (6.1)40.0 (101.6)-1 (2.54) (Both Ends)4.0 (1.8)
3.8”
38383.8 (9.7)38.0 (96.5)0.83 (2.1)-9.0 (4.1)
3838.753.8 (9.7)38.8 (98.4)0.81 (2.1)-9.0 (4.1)
8”
80387.9 (20.1)38.0 (96.5)1.13 (2.9)-29.0 (13.2)
80407.9 (20.1)40.0 (101.6)1.13 (2.9)-29.0 (13.2)

NF Membrane Area (sq. ft.)

Element24 mil31 mil46 mil65 mil80 mil
1812F4.54.02.9N/AN/A
2540F383022N/AN/A
2540M362820N/AN/A
383810087685243
3838.7510489695344
8038450400300240200
8040450400300240200

Recommended Element Cross Flow Rate

ElementFeed Spacer (in mils)2431466580
1.8”m³/hr0.70.70.70.90.9
gpm33344
2.5”m³/hr1.41.41.61.61.8
gpm66778
3.8”m³/hr67889
gpm2629333638
8”m³/hr1618212324
gpm68768998103

The recommended cross flow rate will be subject to differential pressure limitations and specific applications.

Technical Notes For element sizes not listed, please call or email Synder Filtration for details. Synder Filtration can design an element to fit exact needs – specify the element outer diameter (OD) or vessel/housing inner diameter (ID), element inner diameter (ID), and length. Elements are also available with or without a controlled bypass tail. Additional feed spacers are also available. Trials should be conducted to determine optimal application conditions.


Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. For contractual data, always refer to the official OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.