Back to Synder Membranes
Synder logo

Datasheet summary

PY PAN 100kDa

Engineering summary from PDF text extraction for PY PAN 100kDa. Verify every value with the OEM datasheet.

Summary

Product identification

The PY (PAN 100kDa) is a sanitary ultrafiltration spiral-wound element from Synder Filtration, offering an optimal combination of flux and rejection.

Operating limits

Operating Parameters

  • Maximum Temperature: 55°C (131°F)
  • pH Range @ Max Temperature: 3-10.5
  • pH Range @ Ambient Temperature: 3-10

Pressure

  • Max Inlet Pressure: 120 PSI (8.3 Bar)
  • Min Outlet Pressure: 10 PSI (0.7 Bar)
  • Max Differential Pressure per Element: 18 PSI (1.2 Bar)
  • Max Permeate Backpressure: 5 PSI (0.3 Bar)
  • Note: Soft start on boost pumps required to minimize pressure/flow shocks to elements.

Cleaning Parameters

  • Maximum Temperature (Short term <30min): 50°C (122°F)
  • pH Range @ Max Temperature: 3-10.5
  • pH Range @ Ambient Temperature: 3-10

Chlorine

  • Free Chlorine During Operation: 0 Norm ppm (<0.1 Max ppm)
  • Chlorine During CIP at pH 10.8-11.0 and 50°C: 150 Norm ppm (180 Max ppm)
  • Note: Maximum chlorine exposure for all elements is 30 minutes per day at pH and temperature conditions listed above.

Dairy Product Total Solids Limits

Feed Spacer (in mils)31466580
Sweet Whey Max. T.S.15252830
Acid Whey Max. T.S.15242628
Skim Milk Max. T.S.14242628
Whole Milk Max. T.S.15303335
  • Note: Trials should be made to determine temperature and viscosity effects.

Mechanical / hydraulic

Element Dimensions

Element Model No.Diameter (B) inLength (A) inP.W.T. ID
1.8”
1812F1.8120.63
2.5”
25192.519.250.63
2540F2.5400.63
2540M*2.5380.75
3.8”
38383.8380.83
3838.753.838.750.83
38503.8500.83
3938.754.038.750.63
4.3”
43334.3330.83
43354.3350.83
4335.54.335.50.83
43364.3360.83
43384.3380.83
5.8”
58385.8381.14
6.3”
63386.3381.14
63246.3241.14
6.4”
64386.4381.14
64246.4241.14
7.8”
78387.8381.14
78247.8241.14
8”
80388.0381.14
80408.0401.14
82388.2381.14
82408.2401.14
83388.3381.14
83408.3401.14
9.8”
98389.8381.14
10”
1033810.3381.14
  • *1” permeate tube extensions (0.75” OD)

Membrane Area (sq. ft.)

Element Model No.2431466580
1.8”
1812FN/A3.6N/AN/AN/A
2.5”
2519151310N/AN/A
2540F342922N/AN/A
2540M353023N/AN/A
3.8”
38388572584638
3838.758674594739
385010084705246
3938.7510289695347
4.3”
43339986665344
433510591715647
4335.510793725748
433610894735849
4338115100776252
5.8”
583821018414711496
6.3”
63241501341078370
6338246220176136115
6.4”
64241571401128374
6438258230184136122
7.8”
7824242210166132110
7838396344273216180
8”
8038414368287225189
8040414368287225189
8238441384302238201
8240441384302238201
8338450400311245207
8340450400311245207
9.8”
9838N/A564440351296
10”
10338N/A620492386326

Recommended Element Cross Flow Rate

ElementFeed Spacer (in mils)2431466580
1.8”m³/hr11122
gpm45677
2.5”m³/hr22333
gpm910111213
3.8”m³/hr56788
gpm2225293335
4.3”m³/hr6791010
gpm2932384446
5.8”m³/hr1213161819
gpm5159697883
6.3”m³/hr1517202224
gpm65748899105
8”m³/hr2124293335
gpm94107128143154
10”m³/hr4248576468
gpm184213250283299
  • The recommended cross flow rate will be subject to differential pressure limitations and specific applications.

Element Weights

Model No.OD (in.)L (in.)ID* (in.)Weight (lb)Weight (kg)
1812F1.8120.631.00.5
25192.519.250.6320.9
2540F2.5400.6341.8
2540M*2.5380.7541.8
38383.8380.83104.5
3838.753.838.750.83104.5
38503.8500.83135.9
3938.754.038.750.63104.5
43334.3330.83115.0
43354.3350.83115.2
4335.54.335.50.83115.2
43364.3360.83115.2
43384.3380.83125.4
58385.8381.14157
63386.3381.14167
63246.3241.14177.7
64386.4381.142913.2
64246.4241.14188.2
78387.8381.144018.2
78247.8241.142611.8
80388.0381.143817.2
80408.0401.143917.7
82388.2381.143817.2
82408.2401.144018
83388.3381.144018
83408.3401.144018
98389.8381.144219.1
1033810.3381.145022.7
  • *1” permeate tube extensions (0.75” OD)
  • Different diameters are available.
  • Specifications are subject to change without notice.

Applications

  • Corn wet milling
  • Dairy stream clarification

Standard Series Benefits

  • Widest range of UF MWCO’s available
  • Good resistance to pH and temperature
  • High resistance to fouling
  • Customizable dimensions for unique housings

Disclaimer: This summary is generated from an extracted text and may not include all figures, footnotes, or the latest revisions. For contractual data, please refer to the official OEM PDF revision used on your project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.