Datasheet summary
PY PAN 100kDa
Engineering summary from PDF text extraction for PY PAN 100kDa. Verify every value with the OEM datasheet.
Summary
Product identification
The PY (PAN 100kDa) is a sanitary ultrafiltration spiral-wound element from Synder Filtration, offering an optimal combination of flux and rejection.
Operating limits
Operating Parameters
- Maximum Temperature: 55°C (131°F)
- pH Range @ Max Temperature: 3-10.5
- pH Range @ Ambient Temperature: 3-10
Pressure
- Max Inlet Pressure: 120 PSI (8.3 Bar)
- Min Outlet Pressure: 10 PSI (0.7 Bar)
- Max Differential Pressure per Element: 18 PSI (1.2 Bar)
- Max Permeate Backpressure: 5 PSI (0.3 Bar)
- Note: Soft start on boost pumps required to minimize pressure/flow shocks to elements.
Cleaning Parameters
- Maximum Temperature (Short term <30min): 50°C (122°F)
- pH Range @ Max Temperature: 3-10.5
- pH Range @ Ambient Temperature: 3-10
Chlorine
- Free Chlorine During Operation: 0 Norm ppm (<0.1 Max ppm)
- Chlorine During CIP at pH 10.8-11.0 and 50°C: 150 Norm ppm (180 Max ppm)
- Note: Maximum chlorine exposure for all elements is 30 minutes per day at pH and temperature conditions listed above.
Dairy Product Total Solids Limits
| Feed Spacer (in mils) | 31 | 46 | 65 | 80 |
|---|---|---|---|---|
| Sweet Whey Max. T.S. | 15 | 25 | 28 | 30 |
| Acid Whey Max. T.S. | 15 | 24 | 26 | 28 |
| Skim Milk Max. T.S. | 14 | 24 | 26 | 28 |
| Whole Milk Max. T.S. | 15 | 30 | 33 | 35 |
- Note: Trials should be made to determine temperature and viscosity effects.
Mechanical / hydraulic
Element Dimensions
| Element Model No. | Diameter (B) in | Length (A) in | P.W.T. ID |
|---|---|---|---|
| 1.8” | |||
| 1812F | 1.8 | 12 | 0.63 |
| 2.5” | |||
| 2519 | 2.5 | 19.25 | 0.63 |
| 2540F | 2.5 | 40 | 0.63 |
| 2540M* | 2.5 | 38 | 0.75 |
| 3.8” | |||
| 3838 | 3.8 | 38 | 0.83 |
| 3838.75 | 3.8 | 38.75 | 0.83 |
| 3850 | 3.8 | 50 | 0.83 |
| 3938.75 | 4.0 | 38.75 | 0.63 |
| 4.3” | |||
| 4333 | 4.3 | 33 | 0.83 |
| 4335 | 4.3 | 35 | 0.83 |
| 4335.5 | 4.3 | 35.5 | 0.83 |
| 4336 | 4.3 | 36 | 0.83 |
| 4338 | 4.3 | 38 | 0.83 |
| 5.8” | |||
| 5838 | 5.8 | 38 | 1.14 |
| 6.3” | |||
| 6338 | 6.3 | 38 | 1.14 |
| 6324 | 6.3 | 24 | 1.14 |
| 6.4” | |||
| 6438 | 6.4 | 38 | 1.14 |
| 6424 | 6.4 | 24 | 1.14 |
| 7.8” | |||
| 7838 | 7.8 | 38 | 1.14 |
| 7824 | 7.8 | 24 | 1.14 |
| 8” | |||
| 8038 | 8.0 | 38 | 1.14 |
| 8040 | 8.0 | 40 | 1.14 |
| 8238 | 8.2 | 38 | 1.14 |
| 8240 | 8.2 | 40 | 1.14 |
| 8338 | 8.3 | 38 | 1.14 |
| 8340 | 8.3 | 40 | 1.14 |
| 9.8” | |||
| 9838 | 9.8 | 38 | 1.14 |
| 10” | |||
| 10338 | 10.3 | 38 | 1.14 |
- *1” permeate tube extensions (0.75” OD)
Membrane Area (sq. ft.)
| Element Model No. | 24 | 31 | 46 | 65 | 80 |
|---|---|---|---|---|---|
| 1.8” | |||||
| 1812F | N/A | 3.6 | N/A | N/A | N/A |
| 2.5” | |||||
| 2519 | 15 | 13 | 10 | N/A | N/A |
| 2540F | 34 | 29 | 22 | N/A | N/A |
| 2540M | 35 | 30 | 23 | N/A | N/A |
| 3.8” | |||||
| 3838 | 85 | 72 | 58 | 46 | 38 |
| 3838.75 | 86 | 74 | 59 | 47 | 39 |
| 3850 | 100 | 84 | 70 | 52 | 46 |
| 3938.75 | 102 | 89 | 69 | 53 | 47 |
| 4.3” | |||||
| 4333 | 99 | 86 | 66 | 53 | 44 |
| 4335 | 105 | 91 | 71 | 56 | 47 |
| 4335.5 | 107 | 93 | 72 | 57 | 48 |
| 4336 | 108 | 94 | 73 | 58 | 49 |
| 4338 | 115 | 100 | 77 | 62 | 52 |
| 5.8” | |||||
| 5838 | 210 | 184 | 147 | 114 | 96 |
| 6.3” | |||||
| 6324 | 150 | 134 | 107 | 83 | 70 |
| 6338 | 246 | 220 | 176 | 136 | 115 |
| 6.4” | |||||
| 6424 | 157 | 140 | 112 | 83 | 74 |
| 6438 | 258 | 230 | 184 | 136 | 122 |
| 7.8” | |||||
| 7824 | 242 | 210 | 166 | 132 | 110 |
| 7838 | 396 | 344 | 273 | 216 | 180 |
| 8” | |||||
| 8038 | 414 | 368 | 287 | 225 | 189 |
| 8040 | 414 | 368 | 287 | 225 | 189 |
| 8238 | 441 | 384 | 302 | 238 | 201 |
| 8240 | 441 | 384 | 302 | 238 | 201 |
| 8338 | 450 | 400 | 311 | 245 | 207 |
| 8340 | 450 | 400 | 311 | 245 | 207 |
| 9.8” | |||||
| 9838 | N/A | 564 | 440 | 351 | 296 |
| 10” | |||||
| 10338 | N/A | 620 | 492 | 386 | 326 |
Recommended Element Cross Flow Rate
| Element | Feed Spacer (in mils) | 24 | 31 | 46 | 65 | 80 |
|---|---|---|---|---|---|---|
| 1.8” | m³/hr | 1 | 1 | 1 | 2 | 2 |
| gpm | 4 | 5 | 6 | 7 | 7 | |
| 2.5” | m³/hr | 2 | 2 | 3 | 3 | 3 |
| gpm | 9 | 10 | 11 | 12 | 13 | |
| 3.8” | m³/hr | 5 | 6 | 7 | 8 | 8 |
| gpm | 22 | 25 | 29 | 33 | 35 | |
| 4.3” | m³/hr | 6 | 7 | 9 | 10 | 10 |
| gpm | 29 | 32 | 38 | 44 | 46 | |
| 5.8” | m³/hr | 12 | 13 | 16 | 18 | 19 |
| gpm | 51 | 59 | 69 | 78 | 83 | |
| 6.3” | m³/hr | 15 | 17 | 20 | 22 | 24 |
| gpm | 65 | 74 | 88 | 99 | 105 | |
| 8” | m³/hr | 21 | 24 | 29 | 33 | 35 |
| gpm | 94 | 107 | 128 | 143 | 154 | |
| 10” | m³/hr | 42 | 48 | 57 | 64 | 68 |
| gpm | 184 | 213 | 250 | 283 | 299 |
- The recommended cross flow rate will be subject to differential pressure limitations and specific applications.
Element Weights
| Model No. | OD (in.) | L (in.) | ID* (in.) | Weight (lb) | Weight (kg) |
|---|---|---|---|---|---|
| 1812F | 1.8 | 12 | 0.63 | 1.0 | 0.5 |
| 2519 | 2.5 | 19.25 | 0.63 | 2 | 0.9 |
| 2540F | 2.5 | 40 | 0.63 | 4 | 1.8 |
| 2540M* | 2.5 | 38 | 0.75 | 4 | 1.8 |
| 3838 | 3.8 | 38 | 0.83 | 10 | 4.5 |
| 3838.75 | 3.8 | 38.75 | 0.83 | 10 | 4.5 |
| 3850 | 3.8 | 50 | 0.83 | 13 | 5.9 |
| 3938.75 | 4.0 | 38.75 | 0.63 | 10 | 4.5 |
| 4333 | 4.3 | 33 | 0.83 | 11 | 5.0 |
| 4335 | 4.3 | 35 | 0.83 | 11 | 5.2 |
| 4335.5 | 4.3 | 35.5 | 0.83 | 11 | 5.2 |
| 4336 | 4.3 | 36 | 0.83 | 11 | 5.2 |
| 4338 | 4.3 | 38 | 0.83 | 12 | 5.4 |
| 5838 | 5.8 | 38 | 1.14 | 15 | 7 |
| 6338 | 6.3 | 38 | 1.14 | 16 | 7 |
| 6324 | 6.3 | 24 | 1.14 | 17 | 7.7 |
| 6438 | 6.4 | 38 | 1.14 | 29 | 13.2 |
| 6424 | 6.4 | 24 | 1.14 | 18 | 8.2 |
| 7838 | 7.8 | 38 | 1.14 | 40 | 18.2 |
| 7824 | 7.8 | 24 | 1.14 | 26 | 11.8 |
| 8038 | 8.0 | 38 | 1.14 | 38 | 17.2 |
| 8040 | 8.0 | 40 | 1.14 | 39 | 17.7 |
| 8238 | 8.2 | 38 | 1.14 | 38 | 17.2 |
| 8240 | 8.2 | 40 | 1.14 | 40 | 18 |
| 8338 | 8.3 | 38 | 1.14 | 40 | 18 |
| 8340 | 8.3 | 40 | 1.14 | 40 | 18 |
| 9838 | 9.8 | 38 | 1.14 | 42 | 19.1 |
| 10338 | 10.3 | 38 | 1.14 | 50 | 22.7 |
- *1” permeate tube extensions (0.75” OD)
- Different diameters are available.
- Specifications are subject to change without notice.
Applications
- Corn wet milling
- Dairy stream clarification
Standard Series Benefits
- Widest range of UF MWCO’s available
- Good resistance to pH and temperature
- High resistance to fouling
- Customizable dimensions for unique housings
Disclaimer: This summary is generated from an extracted text and may not include all figures, footnotes, or the latest revisions. For contractual data, please refer to the official OEM PDF revision used on your project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.