Datasheet summary
PZ PAN 30kDa
Engineering summary from PDF text extraction for PZ PAN 30kDa. Verify every value with the OEM datasheet.
Summary
Product Identification
Synder Filtration's PZ (PAN 30kDa) Ultrafiltration Elements are sanitary, spiral-wound membrane elements. They offer an optimal combination of flux and rejection.
Operating Limits
General Operating Parameters
- Maximum Temperature: 55°C (131°F)
- pH Range @ Max Temperature: 3-10.5
- pH Range @ Ambient Temperature: 3-10
Pressure
- Max Inlet Pressure: 120 PSI (8.3 Bar)
- Min Outlet Pressure: 10 PSI (0.7 Bar)
- Max Differential Pressure per Element: 18 PSI (1.2 Bar)
- Max Permeate Backpressure: 5 PSI (0.3 Bar)
- Note: Soft start on boost pumps required to minimize pressure/flow shocks to elements.
Cleaning Parameters
- Maximum Temperature (Short term <30min): 50°C (122°F)
- pH Range @ Max Temperature: 3-10.5
- pH Range @ Ambient Temperature: 3-10
Chlorine Limits
- Free Chlorine During Operation:
- Norm: 0 ppm
- Max: <0.1 ppm
- Chlorine During CIP at pH 10.8-11.0 and 50°C:
- Norm: 150 ppm
- Max: 180 ppm
- Note: Maximum chlorine exposure for all elements is 30 minutes per day at pH and temperature conditions listed above.
Feed Water
Dairy Product Total Solids Limits (Maximum T.S. %)
- Feed Spacer 31 mils:
- Sweet Whey: 15
- Acid Whey: 15
- Skim Milk: 14
- Whole Milk: 15
- Feed Spacer 46 mils:
- Sweet Whey: 25
- Acid Whey: 24
- Skim Milk: 24
- Whole Milk: 30
- Feed Spacer 65 mils:
- Sweet Whey: 28
- Acid Whey: 26
- Skim Milk: 26
- Whole Milk: 33
- Feed Spacer 80 mils:
- Sweet Whey: 30
- Acid Whey: 28
- Skim Milk: 28
- Whole Milk: 35
- Note: Trials should be made to determine temperature and viscosity effects.
Mechanical / Hydraulic
Standard Series Benefits
- Widest range of UF MWCO's available
- Good resistance to pH and temperature
- High resistance to fouling
- Customizable dimensions for unique housings
Common Applications
- Corn wet milling
- Enzyme/protein concentration
Element Dimensions
Elements are available in various models with the following representative dimensions:
- 1812F: Diameter 1.8 in, Length 12 in, P.W.T. ID 0.63 in
- 2519: Diameter 2.5 in, Length 19.25 in, P.W.T. ID 0.63 in
- 2540F: Diameter 2.5 in, Length 40 in, P.W.T. ID 0.63 in
- 2540M*: Diameter 2.5 in, Length 38 in, P.W.T. ID 0.75 in
- 3838: Diameter 3.8 in, Length 38 in, P.W.T. ID 0.83 in
- 3838.75: Diameter 3.8 in, Length 38.75 in, P.W.T. ID 0.83 in
- 3850: Diameter 3.8 in, Length 50 in, P.W.T. ID 0.83 in
- 3938.75: Diameter 4.0 in, Length 38.75 in, P.W.T. ID 0.63 in
- 4333: Diameter 4.3 in, Length 33 in, P.W.T. ID 0.83 in
- 4335: Diameter 4.3 in, Length 35 in, P.W.T. ID 0.83 in
- 4335.5: Diameter 4.3 in, Length 35.5 in, P.W.T. ID 0.83 in
- 4336: Diameter 4.3 in, Length 36 in, P.W.T. ID 0.83 in
- 4338: Diameter 4.3 in, Length 38 in, P.W.T. ID 0.83 in
- 5838: Diameter 5.8 in, Length 38 in, P.W.T. ID 1.14 in
- 6338: Diameter 6.3 in, Length 38 in, P.W.T. ID 1.14 in
- 6324: Diameter 6.3 in, Length 24 in, P.W.T. ID 1.14 in
- 6438: Diameter 6.4 in, Length 38 in, P.W.T. ID 1.14 in
- 6424: Diameter 6.4 in, Length 24 in, P.W.T. ID 1.14 in
- 7838: Diameter 7.8 in, Length 38 in, P.W.T. ID 1.14 in
- 7824: Diameter 7.8 in, Length 24 in, P.W.T. ID 1.14 in
- 8038: Diameter 8.0 in, Length 38 in, P.W.T. ID 1.14 in
- 8040: Diameter 8.0 in, Length 40 in, P.W.T. ID 1.14 in
- 8238: Diameter 8.2 in, Length 38 in, P.W.T. ID 1.14 in
- 8240: Diameter 8.2 in, Length 40 in, P.W.T. ID 1.14 in
- 8338: Diameter 8.3 in, Length 38 in, P.W.T. ID 1.14 in
- 8340: Diameter 8.3 in, Length 40 in, P.W.T. ID 1.14 in
- 9838: Diameter 9.8 in, Length 38 in, P.W.T. ID 1.14 in
- 10338: Diameter 10.3 in, Length 38 in, P.W.T. ID 1.14 in *1” permeate tube extensions (0.75” OD)
Element Descriptions (Weight)
- 1812F: OD 1.8 in, L 12 in, ID* 0.63 in, Weight 1.0 lb (0.5 kg)
- 2519: OD 2.5 in, L 19.25 in, ID* 0.63 in, Weight 2 lb (0.9 kg)
- 2540F: OD 2.5 in, L 40 in, ID* 0.63 in, Weight 4 lb (1.8 kg)
- 2540M*: OD 2.5 in, L 38 in, ID* 0.75 in, Weight 4 lb (1.8 kg)
- 3838: OD 3.8 in, L 38 in, ID* 0.83 in, Weight 10 lb (4.5 kg)
- 3838.75: OD 3.8 in, L 38.75 in, ID* 0.83 in, Weight 10 lb (4.5 kg)
- 3850: OD 3.8 in, L 50 in, ID* 0.83 in, Weight 13 lb (5.9 kg)
- 3938.75: OD 4.0 in, L 38.75 in, ID* 0.63 in, Weight 10 lb (4.5 kg)
- 4333: OD 4.3 in, L 33 in, ID* 0.83 in, Weight 11 lb (5.0 kg)
- 4335: OD 4.3 in, L 35 in, ID* 0.83 in, Weight 11 lb (5.2 kg)
- 4335.5: OD 4.3 in, L 35.5 in, ID* 0.83 in, Weight 11 lb (5.2 kg)
- 4336: OD 4.3 in, L 36 in, ID* 0.83 in, Weight 11 lb (5.2 kg)
- 4338: OD 4.3 in, L 38 in, ID* 0.83 in, Weight 12 lb (5.4 kg)
- 5838: OD 5.8 in, L 38 in, ID* 1.14 in, Weight 15 lb (7 kg)
- 6338: OD 6.3 in, L 38 in, ID* 1.14 in, Weight 16 lb (7 kg)
- 6324: OD 6.3 in, L 24 in, ID* 1.14 in, Weight 17 lb (7.7 kg)
- 6438: OD 6.4 in, L 38 in, ID* 1.14 in, Weight 29 lb (13.2 kg)
- 6424: OD 6.4 in, L 24 in, ID* 1.14 in, Weight 18 lb (8.2 kg)
- 7838: OD 7.8 in, L 38 in, ID* 1.14 in, Weight 40 lb (18.2 kg)
- 7824: OD 7.8 in, L 24 in, ID* 1.14 in, Weight 26 lb (11.8 kg)
- 8038: OD 8.0 in, L 38 in, ID* 1.14 in, Weight 38 lb (17.2 kg)
- 8040: OD 8.0 in, L 40 in, ID* 1.14 in, Weight 39 lb (17.7 kg)
- 8238: OD 8.2 in, L 38 in, ID* 1.14 in, Weight 38 lb (17.2 kg)
- 8240: OD 8.2 in, L 40 in, ID* 1.14 in, Weight 40 lb (18 kg)
- 8338: OD 8.3 in, L 38 in, ID* 1.14 in, Weight 40 lb (18 kg)
- 8340: OD 8.3 in, L 40 in, ID* 1.14 in, Weight 40 lb (18 kg)
- 9838: OD 9.8 in, L 38 in, ID* 1.14 in, Weight 42 lb (19.1 kg)
- 10338: OD 10.3 in, L 38 in, ID* 1.14 in, Weight 50 lb (22.7 kg) *1” permeate tube extensions (0.75” OD)
Membrane Area & Recommended Cross Flow Rate
Membrane area (in sq. ft.) and recommended cross flow rates (in m³/hr and gpm) vary significantly by element model number and feed spacer thickness (24, 31, 46, 65, 80 mils). Please refer to the official PDF for exact tabulated values for all models and feed spacer configurations.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. For contractual purposes, the data must match the official OEM PDF revision used on the project.
Official datasheet (PDF)