Datasheet summary
SM PHT PES 20kDa
Engineering summary from PDF text extraction for SM PHT PES 20kDa. Verify every value with the OEM datasheet.
Summary
Product identification
These Ultrafiltration elements offer exceptional physical and chemical durability.
PHT series benefits:
- Conforms to 3-A, FDA, and USDA sanitary standards
- Elimination of chlorine during CIP with hot sanitation
- High resistance to pH, temperature, & fouling
- Customizable dimensions for unique housings
Operating limits
Operating Parameters
- Maximum Temperature: 60°C (140°F)
- pH Range @ Max Temperature: 2-10
- pH Range @ Ambient Temperature: 2-10.5
Pressure
- Max Inlet Pressure: 120 PSI (8.3 Bar)
- Min Outlet Pressure: 10 PSI (0.7 Bar)
- Max Differential Pressure per Element: 18 PSI (1.2 Bar)
- Max Permeate Backpressure: 5 PSI (0.3 Bar)
Note: Soft start on boost pumps is required to minimize pressure/flow shocks to elements.
Cleaning Parameters
- Maximum Temperature (Short term <30min): 85°C (185°F)
- pH Range @ Max Temperature: 2-11
- pH Range @ Ambient Temperature: 2-12.5
Chlorine
- Free Chlorine During Operation: 0 Norm ppm (<0.1 Max ppm)
- Chlorine During CIP at pH 10.8-11.0 and 50°C: 150 Norm ppm (180 Max ppm) Note: Maximum chlorine exposure for all elements is 30 minutes per day at pH and temperature conditions listed above.
Feed water
Dairy Product Total Solids Limits
| Feed Spacer (in mils) | 31 | 46 | 65 | 80 |
|---|---|---|---|---|
| Sweet Whey Max. T.S. | 15 | 25 | 28 | 30 |
| Acid Whey Max. T.S. | 15 | 24 | 26 | 28 |
| Skim Milk Max. T.S. | 14 | 24 | 26 | 28 |
| Whole Milk Max. T.S. | 15 | 30 | 33 | 35 |
Note: Trials should be made to determine temperature and viscosity effects.
Common Applications
- Specialty protein separation
- Skim milk protein concentrate & isolate production
- Beverage clarification
Mechanical / hydraulic
Element Dimensions and Weight
| Model No. | Outer Diameter (in.) | Length (in.) | Permeate Tube ID (in.) | Weight (lb) | Weight (kg) |
|---|---|---|---|---|---|
| 1812F | 1.8 | 12 | 0.63 | 1.0 | 0.5 |
| 2519 | 2.5 | 19.25 | 0.63 | 2 | 0.9 |
| 2540F | 2.5 | 40 | 0.63 | 4 | 1.8 |
| 2540M* | 2.5 | 38 | 0.75 | 4 | 1.8 |
| 3838 | 3.8 | 38 | 0.83 | 10 | 4.5 |
| 3838.75 | 3.8 | 38.75 | 0.83 | 10 | 4.5 |
| 3850 | 3.8 | 50 | 0.83 | 13 | 5.9 |
| 3938.75 | 4.0 | 38.75 | 0.63 | 10 | 4.5 |
| 4333 | 4.3 | 33 | 0.83 | 11 | 5.0 |
| 4335 | 4.3 | 35 | 0.83 | 11 | 5.2 |
| 4335.5 | 4.3 | 35.5 | 0.83 | 11 | 5.2 |
| 4336 | 4.3 | 36 | 0.83 | 11 | 5.2 |
| 4338 | 4.3 | 38 | 0.83 | 12 | 5.4 |
| 5838 | 5.8 | 38 | 1.14 | 15 | 7 |
| 6338 | 6.3 | 38 | 1.14 | 16 | 7 |
| 6324 | 6.3 | 24 | 1.14 | 17 | 7.7 |
| 6438 | 6.4 | 38 | 1.14 | 29 | 13.2 |
| 6424 | 6.4 | 24 | 1.14 | 18 | 8.2 |
| 7838 | 7.8 | 38 | 1.14 | 40 | 18.2 |
| 7824 | 7.8 | 24 | 1.14 | 26 | 11.8 |
| 8038 | 8.0 | 38 | 1.14 | 38 | 17.2 |
| 8040 | 8.0 | 40 | 1.14 | 39 | 17.7 |
| 8238 | 8.2 | 38 | 1.14 | 38 | 17.2 |
| 8240 | 8.2 | 40 | 1.14 | 40 | 18 |
| 8338 | 8.3 | 38 | 1.14 | 40 | 18 |
| 8340 | 8.3 | 40 | 1.14 | 40 | 18 |
| 9838 | 9.8 | 38 | 1.14 | 42 | 19.1 |
| 10338 | 10.3 | 38 | 1.14 | 50 | 22.7 |
*1” permeate tube extensions (0.75” OD) Note: Different diameters are available. Please specify your requirements when ordering. Specifications are subject to change without notice.
Recommended Element Cross Flow Rate
| Element | Feed Spacer (in mils) | 24 | 31 | 46 | 65 | 80 |
|---|---|---|---|---|---|---|
| 1.8” | m³/hr | 1 | 1 | 1 | 2 | 2 |
| gpm | 4 | 5 | 6 | 7 | 7 | |
| 2.5” | m³/hr | 2 | 2 | 3 | 3 | 3 |
| gpm | 9 | 10 | 11 | 12 | 13 | |
| 3.8” | m³/hr | 5 | 6 | 7 | 8 | 8 |
| gpm | 22 | 25 | 29 | 33 | 35 | |
| 4.3” | m³/hr | 6 | 7 | 9 | 10 | 10 |
| gpm | 29 | 32 | 38 | 44 | 46 | |
| 5.8” | m³/hr | 12 | 13 | 16 | 18 | 19 |
| gpm | 51 | 59 | 69 | 78 | 83 | |
| 6.3” | m³/hr | 15 | 17 | 20 | 22 | 24 |
| gpm | 65 | 74 | 88 | 99 | 105 | |
| 8” | m³/hr | 21 | 24 | 29 | 33 | 35 |
| gpm | 94 | 107 | 128 | 143 | 154 | |
| 10” | m³/hr | 42 | 48 | 57 | 64 | 68 |
| gpm | 184 | 213 | 250 | 283 | 299 |
The recommended cross flow rate will be subject to differential pressure limitations and specific applications.
Membrane Area (sq. ft.)
| Element Model No. | Feed Spacer (in mils) | 24 | 31 | 46 | 65 | 80 |
|---|---|---|---|---|---|---|
| 1812F | N/A | 3.6 | N/A | N/A | N/A | |
| 2519 | 15 | 13 | 10 | N/A | N/A | |
| 2540F | 34 | 29 | 22 | N/A | N/A | |
| 2540M | 35 | 30 | 23 | N/A | N/A | |
| 3838 | 85 | 72 | 58 | 46 | 38 | |
| 3838.75 | 86 | 74 | 59 | 47 | 39 | |
| 3850 | 100 | 84 | 70 | 52 | 46 | |
| 3938.75 | 102 | 89 | 69 | 53 | 47 | |
| 4333 | 99 | 86 | 66 | 53 | 44 | |
| 4335 | 105 | 91 | 71 | 56 | 47 | |
| 4335.5 | 107 | 93 | 72 | 57 | 48 | |
| 4336 | 108 | 94 | 73 | 58 | 49 | |
| 4338 | 115 | 100 | 77 | 62 | 52 | |
| 5838 | 210 | 184 | 147 | 114 | 96 | |
| 6324 | 150 | 134 | 107 | 83 | 70 | |
| 6338 | 246 | 220 | 176 | 136 | 115 | |
| 6424 | 157 | 140 | 112 | 83 | 74 | |
| 6438 | 258 | 230 | 184 | 136 | 122 | |
| 7824 | 242 | 210 | 166 | 132 | 110 | |
| 7838 | 396 | 344 | 273 | 216 | 180 | |
| 8038 | 414 | 368 | 287 | 225 | 189 | |
| 8040 | 414 | 368 | 287 | 225 | 189 | |
| 8238 | 441 | 384 | 302 | 238 | 201 | |
| 8240 | 441 | 384 | 302 | 238 | 201 | |
| 8338 | 450 | 400 | 311 | 245 | 207 | |
| 8340 | 450 | 400 | 311 | 245 | 207 | |
| 9838 | N/A | 564 | 440 | 351 | 296 | |
| 10338 | N/A | 620 | 492 | 386 | 326 |
Disclaimer: This summary is based on the provided text extract and may not include all figures, footnotes, or the latest revisions from the original OEM PDF datasheet. For contractual agreements and precise technical specifications, always refer to the specific OEM PDF revision used on your project.