Summary
Product identification
Sanitary Microfiltration Spiral-Wound Element: V0.1 (PVDF 0.1 µm).
Synder Filtration’s Microfiltration Elements offer an optimal combination of both flux and rejection in a comprehensive range of MWCO’s.
Key Benefits:
- Conforms to 3-A, FDA, and USDA sanitary standards
- Good resistance to pH and temperature
- High resistance to fouling
- Customizable dimensions for unique housings
Operating limits
- Maximum Temperature: 55°C (131°F)
- pH Range @ Maximum Temperature: 3-9
- pH Range @ Ambient Temperature: 2-10
- Max Inlet Pressure: 120 PSI (8.3 Bar)
- Min Outlet Pressure: 10 PSI (0.7 Bar)
- Max Differential Pressure per Element: 18 PSI (1.2 Bar)
- Max Permeate Backpressure: 5 PSI (0.3 Bar)
Note: Soft start on boost pumps required to minimize pressure/flow shocks to elements.
Cleaning parameters
- Maximum Temperature (Short term <30min): 50°C (122°F)
- pH Range @ Maximum Temperature: 2-11
- pH Range @ Ambient Temperature: 1.8-11
Chlorine Exposure:
- Free Chlorine During Operation: Norm 0 ppm, Max <0.1 ppm
- Chlorine During CIP at pH 10.8-11.0 and 50°C: Norm 150 ppm, Max 180 ppm
Note: Maximum chlorine exposure for all elements is 30 minutes per day at pH and temperature conditions listed above.
Dairy Product Total Solids Limits
| Feed Spacer (in mils) | 31 | 46 | 65 | 80 |
|---|---|---|---|---|
| Sweet Whey Max. T.S. | 15 | 25 | 28 | 30 |
| Acid Whey Max. T.S. | 15 | 24 | 26 | 28 |
| Skim Milk Max. T.S. | 14 | 24 | 26 | 28 |
| Whole Milk Max. T.S. | 15 | 30 | 33 | 35 |
Note: Trials should be made to determine temperature and viscosity effects.
Common applications
- Fat/Microbial removal
- Protein fractionation
Mechanical / hydraulic
Element Dimensions and Weight: Elements are available in various model numbers with different diameters (OD), lengths, and permeate water tube (P.W.T.) inner diameters (ID). Weights are also provided in pounds and kilograms for each model. *1” permeate tube extensions (0.75” OD) are available for some models. Different diameters are available upon request. See the official PDF for exact tabulated values for each model (e.g., 1812F, 2519, 2540F, 2540M, 3838, etc.).
Membrane Area (SQ. FT.): The membrane area varies depending on the element model number and feed spacer thickness (24, 31, 46, 65, or 80 mils). See the official PDF for exact tabulated values.
Recommended Element Cross Flow Rate: Recommended cross flow rates are provided in m³/hr and gpm for different element diameters and feed spacer thicknesses. These rates are subject to differential pressure limitations and specific applications. See the official PDF for exact tabulated values.
Disclaimer