Datasheet summary

V0.2 PVDF 0.2um

Engineering summary from PDF text extraction for V0.2 PVDF 0.2um. Verify every value with the OEM datasheet.

Summary

Product identification

Sanitary Microfiltration Spiral-Wound Element: V0.2 (PVDF 0.2 µm)

Synder Filtration's Microfiltration Elements offer an optimal combination of both flux and rejection.

Standard Series Benefits:

  • Conforms to 3-A, FDA, and USDA sanitary standards
  • Good resistance to pH and temperature
  • High resistance to fouling
  • Customizable dimensions for unique housings

Common Applications:

  • Microbial removal
  • Enzyme clarification

Operating limits

Operating Parameters:

  • Maximum Temperature: 55°C (131°F)
  • pH Range @ Maximum Temperature: 3-9
  • pH Range @ Ambient Temperature: 2-10

Pressure:

  • Max Inlet Pressure: 120 PSI (8.3 Bar)
  • Min Outlet Pressure: 10 PSI (0.7 Bar)
  • Max Differential Pressure per Element: 18 PSI (1.2 Bar)
  • Max Permeate Backpressure: 5 PSI (0.3 Bar)
  • Note: Soft start on boost pumps required to minimize pressure/flow shocks to elements.

Cleaning Parameters:

  • Maximum Temperature (Short term <30 min): 50°C (122°F)
  • pH Range @ Maximum Temperature: 2-11
  • pH Range @ Ambient Temperature: 1.8-11
  • Chlorine:
    • Free Chlorine During Operation: 0 Norm ppm, <0.1 Max ppm
    • Chlorine During CIP at pH 10.8-11.0 and 50°C: 150 Norm ppm, 180 Max ppm
  • Note: Maximum chlorine exposure for all elements is 30 minutes per day at pH and temperature conditions listed above.

Feed water

Dairy Product Total Solids (T.S.) Limits:

  • Sweet Whey Max. T.S.:
    • 31 mil Feed Spacer: 15
    • 46 mil Feed Spacer: 25
    • 65 mil Feed Spacer: 28
    • 80 mil Feed Spacer: 30
  • Acid Whey Max. T.S.:
    • 31 mil Feed Spacer: 15
    • 46 mil Feed Spacer: 24
    • 65 mil Feed Spacer: 26
    • 80 mil Feed Spacer: 28
  • Skim Milk Max. T.S.:
    • 31 mil Feed Spacer: 14
    • 46 mil Feed Spacer: 24
    • 65 mil Feed Spacer: 26
    • 80 mil Feed Spacer: 28
  • Whole Milk Max. T.S.:
    • 31 mil Feed Spacer: 15
    • 46 mil Feed Spacer: 30
    • 65 mil Feed Spacer: 33
    • 80 mil Feed Spacer: 35
  • Note: Trials should be made to determine temperature and viscosity effects.

Mechanical / hydraulic

Element Dimensions:

Element Model No.Diameter (B) inLength (A) inP.W.T. ID
1812F1.8120.63
25192.519.250.63
2540F2.5400.63
2540M*2.5380.75
38383.8380.83
3838.753.838.750.83
38503.8500.83
3938.754.038.750.63
43334.3330.83
43354.3350.83
4335.54.335.50.83
43364.3360.83
43384.3380.83
58385.8381.14
63386.3381.14
63246.3241.14
64386.4381.14
64246.4241.14
78387.8381.14
78247.8241.14
80388.0381.14
80408.0401.14
82388.2381.14
82408.2401.14
83388.3381.14
83408.3401.14
98389.8381.14
1033810.3381.14
*1” permeate tube extensions (0.75” OD)

Membrane Area (SQ. FT.)

Element Model No.Feed Spacer (in mils)
24 | 31 | 46 | 65 | 80
1.8”
1812FN/A | 3.6 | N/A | N/A | N/A
2.5”
251915 | 13 | 10 | N/A | N/A
2540F34 | 29 | 22 | N/A | N/A
2540M35 | 30 | 23 | N/A | N/A
3.8”
383885 | 72 | 58 | 46 | 38
3838.7586 | 74 | 59 | 47 | 39
3850100 | 84 | 70 | 52 | 46
3938.75102 | 89 | 69 | 53 | 47
4.3”
433399 | 86 | 66 | 53 | 44
4335105 | 91 | 71 | 56 | 47
4335.5107 | 93 | 72 | 57 | 48
4336108 | 94 | 73 | 58 | 49
4338115 | 100 | 77 | 62 | 52
5.8”
5838210 | 184 | 147 | 114 | 96
6.3”
6324150 | 134 | 107 | 83 | 70
6338246 | 220 | 176 | 136 | 115
6.4”
6424157 | 140 | 112 | 83 | 74
6438258 | 230 | 184 | 136 | 122
7.8”
7824242 | 210 | 166 | 132 | 110
7838396 | 344 | 273 | 216 | 180
8”
8038414 | 368 | 287 | 225 | 189
8040414 | 368 | 287 | 225 | 189
8238441 | 384 | 302 | 238 | 201
8240441 | 384 | 302 | 238 | 201
8338450 | 400 | 311 | 245 | 207
8340450 | 400 | 311 | 245 | 207
9.8”
9838N/A | 564 | 440 | 351 | 296
10”
10338N/A | 620 | 492 | 386 | 326

Recommended Element Cross Flow Rate

ElementFeed Spacer (in mils)
24 | 31 | 46 | 65 | 80
1.8”
m³/hr1 | 1 | 1 | 2 | 2
gpm4 | 5 | 6 | 7 | 7
2.5”
m³/hr2 | 2 | 3 | 3 | 3
gpm9 | 10 | 11 | 12 | 13
3.8”
m³/hr5 | 6 | 7 | 8 | 8
gpm22 | 25 | 29 | 33 | 35
4.3”
m³/hr6 | 7 | 9 | 10 | 10
gpm29 | 32 | 38 | 44 | 46
5.8”
m³/hr12 | 13 | 16 | 18 | 19
gpm51 | 59 | 69 | 78 | 83
6.3”
m³/hr15 | 17 | 20 | 22 | 24
gpm65 | 74 | 88 | 99 | 105
8”
m³/hr21 | 24 | 29 | 33 | 35
gpm94 | 107 | 128 | 143 | 154
10”
m³/hr42 | 48 | 57 | 64 | 68
gpm184 | 213 | 250 | 283 | 299
The recommended cross flow rate will be subject to differential pressure limitations and specific applications.

Element Descriptions

Model No.OD (in.)L (in.)ID* (in.)Weight (lb)Weight (kg)
1812F1.8120.631.00.5
25192.519.250.6320.9
2540F2.5400.6341.8
2540M*2.5380.7541.8
38383.8380.83104.5
3838.753.838.750.83104.5
38503.8500.83135.9
3938.754.038.750.63104.5
43334.3330.83115.0
43354.3350.83115.2
4335.54.335.50.83115.2
43364.3360.83115.2
43384.3380.83125.4
58385.8381.14157
63386.3381.14167
63246.3241.14177.7
64386.4381.142913.2
64246.4241.14188.2
78387.8381.144018.2
78247.8241.142611.8
80388.0381.143817.2
80408.0401.143917.7
82388.2381.143817.2
82408.2401.144018
83388.3381.144018
83408.3401.144018
98389.8381.144219.1
1033810.3381.145022.7
*1” permeate tube extensions (0.75” OD)

Different diameters are available; specify requirements when ordering. Elements are also available with or without a controlled bypass tail. Additional feed spacers are available.