Datasheet summary
V0.2 PVDF 0.2um
Engineering summary from PDF text extraction for V0.2 PVDF 0.2um. Verify every value with the OEM datasheet.
Summary
Product identification
Sanitary Microfiltration Spiral-Wound Element: V0.2 (PVDF 0.2 µm)
Synder Filtration's Microfiltration Elements offer an optimal combination of both flux and rejection.
Standard Series Benefits:
- Conforms to 3-A, FDA, and USDA sanitary standards
- Good resistance to pH and temperature
- High resistance to fouling
- Customizable dimensions for unique housings
Common Applications:
- Microbial removal
- Enzyme clarification
Operating limits
Operating Parameters:
- Maximum Temperature: 55°C (131°F)
- pH Range @ Maximum Temperature: 3-9
- pH Range @ Ambient Temperature: 2-10
Pressure:
- Max Inlet Pressure: 120 PSI (8.3 Bar)
- Min Outlet Pressure: 10 PSI (0.7 Bar)
- Max Differential Pressure per Element: 18 PSI (1.2 Bar)
- Max Permeate Backpressure: 5 PSI (0.3 Bar)
- Note: Soft start on boost pumps required to minimize pressure/flow shocks to elements.
Cleaning Parameters:
- Maximum Temperature (Short term <30 min): 50°C (122°F)
- pH Range @ Maximum Temperature: 2-11
- pH Range @ Ambient Temperature: 1.8-11
- Chlorine:
- Free Chlorine During Operation: 0 Norm ppm, <0.1 Max ppm
- Chlorine During CIP at pH 10.8-11.0 and 50°C: 150 Norm ppm, 180 Max ppm
- Note: Maximum chlorine exposure for all elements is 30 minutes per day at pH and temperature conditions listed above.
Feed water
Dairy Product Total Solids (T.S.) Limits:
- Sweet Whey Max. T.S.:
- 31 mil Feed Spacer: 15
- 46 mil Feed Spacer: 25
- 65 mil Feed Spacer: 28
- 80 mil Feed Spacer: 30
- Acid Whey Max. T.S.:
- 31 mil Feed Spacer: 15
- 46 mil Feed Spacer: 24
- 65 mil Feed Spacer: 26
- 80 mil Feed Spacer: 28
- Skim Milk Max. T.S.:
- 31 mil Feed Spacer: 14
- 46 mil Feed Spacer: 24
- 65 mil Feed Spacer: 26
- 80 mil Feed Spacer: 28
- Whole Milk Max. T.S.:
- 31 mil Feed Spacer: 15
- 46 mil Feed Spacer: 30
- 65 mil Feed Spacer: 33
- 80 mil Feed Spacer: 35
- Note: Trials should be made to determine temperature and viscosity effects.
Mechanical / hydraulic
Element Dimensions:
| Element Model No. | Diameter (B) in | Length (A) in | P.W.T. ID |
|---|---|---|---|
| 1812F | 1.8 | 12 | 0.63 |
| 2519 | 2.5 | 19.25 | 0.63 |
| 2540F | 2.5 | 40 | 0.63 |
| 2540M* | 2.5 | 38 | 0.75 |
| 3838 | 3.8 | 38 | 0.83 |
| 3838.75 | 3.8 | 38.75 | 0.83 |
| 3850 | 3.8 | 50 | 0.83 |
| 3938.75 | 4.0 | 38.75 | 0.63 |
| 4333 | 4.3 | 33 | 0.83 |
| 4335 | 4.3 | 35 | 0.83 |
| 4335.5 | 4.3 | 35.5 | 0.83 |
| 4336 | 4.3 | 36 | 0.83 |
| 4338 | 4.3 | 38 | 0.83 |
| 5838 | 5.8 | 38 | 1.14 |
| 6338 | 6.3 | 38 | 1.14 |
| 6324 | 6.3 | 24 | 1.14 |
| 6438 | 6.4 | 38 | 1.14 |
| 6424 | 6.4 | 24 | 1.14 |
| 7838 | 7.8 | 38 | 1.14 |
| 7824 | 7.8 | 24 | 1.14 |
| 8038 | 8.0 | 38 | 1.14 |
| 8040 | 8.0 | 40 | 1.14 |
| 8238 | 8.2 | 38 | 1.14 |
| 8240 | 8.2 | 40 | 1.14 |
| 8338 | 8.3 | 38 | 1.14 |
| 8340 | 8.3 | 40 | 1.14 |
| 9838 | 9.8 | 38 | 1.14 |
| 10338 | 10.3 | 38 | 1.14 |
| *1” permeate tube extensions (0.75” OD) |
Membrane Area (SQ. FT.)
| Element Model No. | Feed Spacer (in mils) |
|---|---|
| 24 | 31 | 46 | 65 | 80 | |
| 1.8” | |
| 1812F | N/A | 3.6 | N/A | N/A | N/A |
| 2.5” | |
| 2519 | 15 | 13 | 10 | N/A | N/A |
| 2540F | 34 | 29 | 22 | N/A | N/A |
| 2540M | 35 | 30 | 23 | N/A | N/A |
| 3.8” | |
| 3838 | 85 | 72 | 58 | 46 | 38 |
| 3838.75 | 86 | 74 | 59 | 47 | 39 |
| 3850 | 100 | 84 | 70 | 52 | 46 |
| 3938.75 | 102 | 89 | 69 | 53 | 47 |
| 4.3” | |
| 4333 | 99 | 86 | 66 | 53 | 44 |
| 4335 | 105 | 91 | 71 | 56 | 47 |
| 4335.5 | 107 | 93 | 72 | 57 | 48 |
| 4336 | 108 | 94 | 73 | 58 | 49 |
| 4338 | 115 | 100 | 77 | 62 | 52 |
| 5.8” | |
| 5838 | 210 | 184 | 147 | 114 | 96 |
| 6.3” | |
| 6324 | 150 | 134 | 107 | 83 | 70 |
| 6338 | 246 | 220 | 176 | 136 | 115 |
| 6.4” | |
| 6424 | 157 | 140 | 112 | 83 | 74 |
| 6438 | 258 | 230 | 184 | 136 | 122 |
| 7.8” | |
| 7824 | 242 | 210 | 166 | 132 | 110 |
| 7838 | 396 | 344 | 273 | 216 | 180 |
| 8” | |
| 8038 | 414 | 368 | 287 | 225 | 189 |
| 8040 | 414 | 368 | 287 | 225 | 189 |
| 8238 | 441 | 384 | 302 | 238 | 201 |
| 8240 | 441 | 384 | 302 | 238 | 201 |
| 8338 | 450 | 400 | 311 | 245 | 207 |
| 8340 | 450 | 400 | 311 | 245 | 207 |
| 9.8” | |
| 9838 | N/A | 564 | 440 | 351 | 296 |
| 10” | |
| 10338 | N/A | 620 | 492 | 386 | 326 |
Recommended Element Cross Flow Rate
| Element | Feed Spacer (in mils) |
|---|---|
| 24 | 31 | 46 | 65 | 80 | |
| 1.8” | |
| m³/hr | 1 | 1 | 1 | 2 | 2 |
| gpm | 4 | 5 | 6 | 7 | 7 |
| 2.5” | |
| m³/hr | 2 | 2 | 3 | 3 | 3 |
| gpm | 9 | 10 | 11 | 12 | 13 |
| 3.8” | |
| m³/hr | 5 | 6 | 7 | 8 | 8 |
| gpm | 22 | 25 | 29 | 33 | 35 |
| 4.3” | |
| m³/hr | 6 | 7 | 9 | 10 | 10 |
| gpm | 29 | 32 | 38 | 44 | 46 |
| 5.8” | |
| m³/hr | 12 | 13 | 16 | 18 | 19 |
| gpm | 51 | 59 | 69 | 78 | 83 |
| 6.3” | |
| m³/hr | 15 | 17 | 20 | 22 | 24 |
| gpm | 65 | 74 | 88 | 99 | 105 |
| 8” | |
| m³/hr | 21 | 24 | 29 | 33 | 35 |
| gpm | 94 | 107 | 128 | 143 | 154 |
| 10” | |
| m³/hr | 42 | 48 | 57 | 64 | 68 |
| gpm | 184 | 213 | 250 | 283 | 299 |
| The recommended cross flow rate will be subject to differential pressure limitations and specific applications. |
Element Descriptions
| Model No. | OD (in.) | L (in.) | ID* (in.) | Weight (lb) | Weight (kg) |
|---|---|---|---|---|---|
| 1812F | 1.8 | 12 | 0.63 | 1.0 | 0.5 |
| 2519 | 2.5 | 19.25 | 0.63 | 2 | 0.9 |
| 2540F | 2.5 | 40 | 0.63 | 4 | 1.8 |
| 2540M* | 2.5 | 38 | 0.75 | 4 | 1.8 |
| 3838 | 3.8 | 38 | 0.83 | 10 | 4.5 |
| 3838.75 | 3.8 | 38.75 | 0.83 | 10 | 4.5 |
| 3850 | 3.8 | 50 | 0.83 | 13 | 5.9 |
| 3938.75 | 4.0 | 38.75 | 0.63 | 10 | 4.5 |
| 4333 | 4.3 | 33 | 0.83 | 11 | 5.0 |
| 4335 | 4.3 | 35 | 0.83 | 11 | 5.2 |
| 4335.5 | 4.3 | 35.5 | 0.83 | 11 | 5.2 |
| 4336 | 4.3 | 36 | 0.83 | 11 | 5.2 |
| 4338 | 4.3 | 38 | 0.83 | 12 | 5.4 |
| 5838 | 5.8 | 38 | 1.14 | 15 | 7 |
| 6338 | 6.3 | 38 | 1.14 | 16 | 7 |
| 6324 | 6.3 | 24 | 1.14 | 17 | 7.7 |
| 6438 | 6.4 | 38 | 1.14 | 29 | 13.2 |
| 6424 | 6.4 | 24 | 1.14 | 18 | 8.2 |
| 7838 | 7.8 | 38 | 1.14 | 40 | 18.2 |
| 7824 | 7.8 | 24 | 1.14 | 26 | 11.8 |
| 8038 | 8.0 | 38 | 1.14 | 38 | 17.2 |
| 8040 | 8.0 | 40 | 1.14 | 39 | 17.7 |
| 8238 | 8.2 | 38 | 1.14 | 38 | 17.2 |
| 8240 | 8.2 | 40 | 1.14 | 40 | 18 |
| 8338 | 8.3 | 38 | 1.14 | 40 | 18 |
| 8340 | 8.3 | 40 | 1.14 | 40 | 18 |
| 9838 | 9.8 | 38 | 1.14 | 42 | 19.1 |
| 10338 | 10.3 | 38 | 1.14 | 50 | 22.7 |
| *1” permeate tube extensions (0.75” OD) |
Different diameters are available; specify requirements when ordering. Elements are also available with or without a controlled bypass tail. Additional feed spacers are available.