Datasheet summary
VT PES 3kDa
Engineering summary from PDF text extraction for VT PES 3kDa. Verify every value with the OEM datasheet.
Summary
Product identification
This document describes the VT (PES 3kDa) Sanitary Ultrafiltration Spiral-Wound Element. It is designed to offer an optimal combination of flux and rejection across a comprehensive range of molecular weight cut-offs (MWCOs).
Operating limits
- Maximum Temperature: 55°C (131°F)
- pH Range @ Max Temperature: 3-9
- pH Range @ Ambient Temperature: 2-10
- Max Inlet Pressure: 120 PSI (8.3 Bar)
- Min Outlet Pressure: 10 PSI (0.7 Bar)
- Max Differential Pressure per Element: 18 PSI (1.2 Bar)
- Max Permeate Backpressure: 5 PSI (0.3 Bar)
- Note: Soft start on boost pumps required to minimize pressure/flow shocks to elements.
Cleaning Parameters
- Maximum Temperature (Short term <30min): 50°C (122°F)
- pH Range @ Max Temperature: 2-11
- pH Range @ Ambient Temperature: 1.8-11
- Free Chlorine During Operation: 0 Norm ppm, <0.1 Max ppm
- Chlorine During CIP at pH 10.8-11.0 and 50°C: 150 Norm ppm, 180 Max ppm
- Note: Maximum chlorine exposure for all elements is 30 minutes per day at pH and temperature conditions listed above.
Dairy Product Total Solids Limits
(Note: Trials should be made to determine temperature and viscosity effects.)
| Feed Spacer (in mils) | 31 | 46 | 65 | 80 |
|---|---|---|---|---|
| Sweet Whey Max. T.S. | 15 | 25 | 28 | 30 |
| Acid Whey Max. T.S. | 15 | 24 | 26 | 28 |
| Skim Milk Max. T.S. | 14 | 24 | 26 | 28 |
| Whole Milk Max. T.S. | 15 | 30 | 33 | 35 |
Benefits
- Conforms to 3-A, FDA, and USDA sanitary standards
- Widest range of UF MWCO’s available
- Good resistance to pH and temperature
- High resistance to fouling
- Customizable dimensions for unique housings
Applications
- Antibiotic concentration
- Protein & polypeptide concentration
Mechanical / hydraulic
Element Dimensions and Weights
| Model No. | OD (in.) | L (in.) | ID* (in.) | Weight (lb) | Weight (kg) |
|---|---|---|---|---|---|
| 1812F | 1.8 | 12 | 0.63 | 1.0 | 0.5 |
| 2519 | 2.5 | 19.25 | 0.63 | 2 | 0.9 |
| 2540F | 2.5 | 40 | 0.63 | 4 | 1.8 |
| 2540M* | 2.5 | 38 | 0.75 | 4 | 1.8 |
| 3838 | 3.8 | 38 | 0.83 | 10 | 4.5 |
| 3838.75 | 3.8 | 38.75 | 0.83 | 10 | 4.5 |
| 3850 | 3.8 | 50 | 0.83 | 13 | 5.9 |
| 3938.75 | 4.0 | 38.75 | 0.63 | 10 | 4.5 |
| 4333 | 4.3 | 33 | 0.83 | 11 | 5.0 |
| 4335 | 4.3 | 35 | 0.83 | 11 | 5.2 |
| 4335.5 | 4.3 | 35.5 | 0.83 | 11 | 5.2 |
| 4336 | 4.3 | 36 | 0.83 | 11 | 5.2 |
| 4338 | 4.3 | 38 | 0.83 | 12 | 5.4 |
| 5838 | 5.8 | 38 | 1.14 | 15 | 7 |
| 6338 | 6.3 | 38 | 1.14 | 16 | 7 |
| 6324 | 6.3 | 24 | 1.14 | 17 | 7.7 |
| 6438 | 6.4 | 38 | 1.14 | 29 | 13.2 |
| 6424 | 6.4 | 24 | 1.14 | 18 | 8.2 |
| 7838 | 7.8 | 38 | 1.14 | 40 | 18.2 |
| 7824 | 7.8 | 24 | 1.14 | 26 | 11.8 |
| 8038 | 8.0 | 38 | 1.14 | 38 | 17.2 |
| 8040 | 8.0 | 40 | 1.14 | 39 | 17.7 |
| 8238 | 8.2 | 38 | 1.14 | 38 | 17.2 |
| 8240 | 8.2 | 40 | 1.14 | 40 | 18 |
| 8338 | 8.3 | 38 | 1.14 | 40 | 18 |
| 8340 | 8.3 | 40 | 1.14 | 40 | 18 |
| 9838 | 9.8 | 38 | 1.14 | 42 | 19.1 |
| 10338 | 10.3 | 38 | 1.14 | 50 | 22.7 |
*Note: 2540M has 1” permeate tube extensions (0.75” OD). Different diameters are available; please specify requirements when ordering.
Membrane Area
| Element Model No. | Feed Spacer (in mils) | 24 | 31 | 46 | 65 | 80 |
|---|---|---|---|---|---|---|
| 1.8” | 1812F | N/A | 3.6 | N/A | N/A | N/A |
| 2.5” | 2519 | 15 | 13 | 10 | N/A | N/A |
| 2540F | 34 | 29 | 22 | N/A | N/A | |
| 2540M | 35 | 30 | 23 | N/A | N/A | |
| 3.8” | 3838 | 85 | 72 | 58 | 46 | 38 |
| 3838.75 | 86 | 74 | 59 | 47 | 39 | |
| 3850 | 100 | 84 | 70 | 52 | 46 | |
| 3938.75 | 102 | 89 | 69 | 53 | 47 | |
| 4.3” | 4333 | 99 | 86 | 66 | 53 | 44 |
| 4335 | 105 | 91 | 71 | 56 | 47 | |
| 4335.5 | 107 | 93 | 72 | 57 | 48 | |
| 4336 | 108 | 94 | 73 | 58 | 49 | |
| 4338 | 115 | 100 | 77 | 62 | 52 | |
| 5.8” | 5838 | 210 | 184 | 147 | 114 | 96 |
| 6.3” | 6324 | 150 | 134 | 107 | 83 | 70 |
| 6338 | 246 | 220 | 176 | 136 | 115 | |
| 6.4” | 6424 | 157 | 140 | 112 | 83 | 74 |
| 6438 | 258 | 230 | 184 | 136 | 122 | |
| 7.8” | 7824 | 242 | 210 | 166 | 132 | 110 |
| 7838 | 396 | 344 | 273 | 216 | 180 | |
| 8” | 8038 | 414 | 368 | 287 | 225 | 189 |
| 8040 | 414 | 368 | 287 | 225 | 189 | |
| 8238 | 441 | 384 | 302 | 238 | 201 | |
| 8240 | 441 | 384 | 302 | 238 | 201 | |
| 8338 | 450 | 400 | 311 | 245 | 207 | |
| 8340 | 450 | 400 | 311 | 245 | 207 | |
| 9.8” | 9838 | N/A | 564 | 440 | 351 | 296 |
| 10” | 10338 | N/A | 620 | 492 | 386 | 326 |
Recommended Element Cross Flow Rate
| Element | Feed Spacer (in mils) | 24 m³/hr (gpm) | 31 m³/hr (gpm) | 46 m³/hr (gpm) | 65 m³/hr (gpm) | 80 m³/hr (gpm) |
|---|---|---|---|---|---|---|
| 1.8” | 1 (4) | 1 (5) | 1 (6) | 2 (7) | 2 (7) | |
| 2.5” | 2 (9) | 2 (10) | 3 (11) | 3 (12) | 3 (13) | |
| 3.8” | 5 (22) | 6 (25) | 7 (29) | 8 (33) | 8 (35) | |
| 4.3” | 6 (29) | 7 (32) | 9 (38) | 10 (44) | 10 (46) | |
| 5.8” | 12 (51) | 13 (59) | 16 (69) | 18 (78) | 19 (83) | |
| 6.3” | 15 (65) | 17 (74) | 20 (88) | 22 (99) | 24 (105) | |
| 8” | 21 (94) | 24 (107) | 29 (128) | 33 (143) | 35 (154) | |
| 10” | 42 (184) | 48 (213) | 57 (250) | 64 (283) | 68 (299) |
The recommended cross flow rate will be subject to differential pressure limitations and specific applications. Please consult Synder Filtration if additional information is needed.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original PDF datasheet. For contractual data, always refer to the specific OEM PDF revision used on your project.
Official datasheet (PDF)