Back to Synder Membranes
Synder logo

Datasheet summary

VT PHT PES 3kDa

Engineering summary from PDF text extraction for VT PHT PES 3kDa. Verify every value with the OEM datasheet.

Summary

Product identification

Synder Filtration's PHT Series of Ultrafiltration (UF) elements offers exceptional physical and chemical durability. This specific product is a PHT Sanitary Ultrafiltration Spiral-Wound Element: VT (PES 3kDa).

Operating limits

  • Maximum Temperature: 60°C (140°F)
  • pH Range @ Max Temperature: 2-10
  • pH Range @ Ambient Temperature: 2-10.5
  • Max Inlet Pressure: 120 PSI (8.3 Bar)
  • Min Outlet Pressure: 10 PSI (0.7 Bar)
  • Max Differential Pressure per Element: 18 PSI (1.2 Bar)
  • Max Permeate Backpressure: 5 PSI (0.3 Bar)

Note: Soft start on boost pumps is required to minimize pressure/flow shocks to elements.

Cleaning parameters

  • Maximum Temperature (Short term <30min): 85°C (185°F)
  • pH Range @ Max Temperature: 2-11
  • pH Range @ Ambient Temperature: 2-12.5

Chlorine Limits

ParameterNorm ppmMax ppm
Free Chlorine During Operation0<0.1
Chlorine During CIP at pH 10.8-11.0 and 50°C150180

Note: Maximum chlorine exposure for all elements is 30 minutes per day at the pH and temperature conditions listed above.

Feed water

Dairy Product Total Solids Limits

Feed Spacer (in mils)31466580
Sweet Whey Max. T.S.15252830
Acid Whey Max. T.S.15242628
Skim Milk Max. T.S.14242628
Whole Milk Max. T.S.15303335

Note: Trials should be made to determine temperature and viscosity effects.

Mechanical / hydraulic

Element Dimensions and Weights

Model No.OD (in.)Length (in.)ID* (in.)Weight (lb)Weight (kg)
1812F1.8120.631.00.5
25192.519.250.6320.9
2540F2.5400.6341.8
2540M*2.5380.7541.8
38383.8380.83104.5
3838.753.838.750.83104.5
38503.8500.83135.9
3938.754.038.750.63104.5
43334.3330.83115.0
43354.3350.83115.2
4335.54.335.50.83115.2
43364.3360.83115.2
43384.3380.83125.4
58385.8381.14157
63386.3381.14167
63246.3241.14177.7
64386.4381.142913.2
64246.4241.14188.2
78387.8381.144018.2
78247.8241.142611.8
80388.0381.143817.2
80408.0401.143917.7
82388.2381.143817.2
82408.2401.144018
83388.3381.144018
83408.3401.144018
98389.8381.144219.1
1033810.3381.145022.7

*Note: 2540M model has 1" permeate tube extensions (0.75" OD).

Recommended Element Cross Flow Rate

ElementFeed Spacer (in mils)2431466580
1.8”m³/hr11122
gpm45677
2.5”m³/hr22333
gpm910111213
3.8”m³/hr56788
gpm2225293335
4.3”m³/hr6791010
gpm2932384446
5.8”m³/hr1213161819
gpm5159697883
6.3”m³/hr1517202224
gpm65748899105
8”m³/hr2124293335
gpm94107128143154
10”m³/hr4248576468
gpm184213250283299

The recommended cross flow rate will be subject to differential pressure limitations and specific applications.

Membrane Area (Sq. Ft.)

Element Model No.Feed Spacer (in mils)2431466580
1812FN/A3.6N/AN/AN/A
2519151310N/AN/AN/A
2540F342922N/AN/AN/A
2540M353023N/AN/AN/A
38388572584638
3838.758674594739
385010084705246
3938.7510289695347
43339986665344
433510591715647
4335.510793725748
433610894735849
4338115100776252
583821018414711496
63241501341078370
6338246220176136115
64241571401128374
6438258230184136122
7824242210166132110
7838396344273216180
8038414368287225189
8040414368287225189
8238441384302238201
8240441384302238201
8338450400311245207
8340450400311245207
9838N/A564440351296
10338N/A620492386326

Benefits

  • Conforms to 3-A, FDA, and USDA sanitary standards
  • Elimination of chlorine during CIP with hot sanitation
  • High resistance to pH, temperature, & fouling
  • Customizable dimensions for unique housings

Common Applications

  • Antibiotic concentration
  • Protein & polypeptide concentration

Disclaimer: This summary is based on the provided text extract. It may not include all figures, footnotes, or the latest revisions present in the official OEM PDF datasheet. For contractual data, please refer to the specific OEM PDF revision used on your project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.