XT PES 1kDa

Engineering summary from PDF text extraction for XT PES 1kDa. Verify every value with the OEM datasheet.

Summary

Product identification

This is a Sanitary Ultrafiltration Spiral-Wound Element, model XT (PES 1kDa). These Synder Filtration Ultrafiltration Elements offer an optimal combination of flux and rejection.

Operating limits

Recommended Operating Parameters

  • Maximum Temperature: 55°C (131°F)
  • pH Range @ Max Temperature: 3-9
  • pH Range @ Ambient Temperature: 2-10

Pressure

  • Max Inlet Pressure: 120 PSI (8.3 Bar)
  • Min Outlet Pressure: 10 PSI (0.7 Bar)
  • Max Differential Pressure per Element: 18 PSI (1.2 Bar)
  • Max Permeate Backpressure: 5 PSI (0.3 Bar)
    • Note: Soft start on boost pumps required to minimize pressure/flow shocks to elements.

Cleaning Parameters

  • Maximum Temperature (Short term <30min): 50°C (122°F)
  • pH Range @ Max Temperature: 2-11
  • pH Range @ Ambient Temperature: 1.8-11

Chlorine

  • Free Chlorine During Operation: Norm 0 ppm, Max <0.1 ppm
  • Chlorine During CIP at pH 10.8-11.0 and 50°C: Norm 150 ppm, Max 180 ppm
    • Note: Maximum chlorine exposure for all elements is 30 minutes per day at pH and temperature conditions listed above.

Dairy Product Total Solids Limits

Feed Spacer (in mils)31466580
Sweet Whey Max. T.S.15252830
Acid Whey Max. T.S.15242628
Skim Milk Max. T.S.14242628
Whole Milk Max. T.S.15303335

Note: Trials should be made to determine temperature and viscosity effects.

Mechanical / hydraulic

Element Dimensions

Element Model No.Diameter (B) inLength (A) inP.W.T. ID
1.8”
1812F1.8120.63
2.5”
25192.519.250.63
2540F2.5400.63
2540M*2.5380.75
3.8”
38383.8380.83
3838.753.838.750.83
38503.8500.83
3938.754.038.750.63
4.3”
43334.3330.83
43354.3350.83
4335.54.335.50.83
43364.3360.83
43384.3380.83
5.8”
58385.8381.14
6.3”
63386.3381.14
63246.3241.14
6.4”
64386.4381.14
64246.4241.14
7.8”
78387.8381.14
78247.8241.14
8”
80388.0381.14
80408.0401.14
82388.2381.14
82408.2401.14
83388.3381.14
83408.3401.14
9.8”
98389.8381.14
10”
1033810.3381.14

*1” permeate tube extensions (0.75” OD)

Element Descriptions (Weight)

Model No.OD (in.)L (in.)ID* (in.)Weight (lb)Weight (kg)
1812F1.8120.631.00.5
25192.519.250.6320.9
2540F2.5400.6341.8
2540M*2.5380.7541.8
38383.8380.83104.5
3838.753.838.750.83104.5
38503.8500.83135.9
3938.754.038.750.63104.5
43334.3330.83115.0
43354.3350.83115.2
4335.54.335.50.83115.2
43364.3360.83115.2
43384.3380.83125.4
58385.8381.14157
63386.3381.14167
63246.3241.14177.7
64386.4381.142913.2
64246.4241.14188.2
78387.8381.144018.2
78247.8241.142611.8
80388.0381.143817.2
80408.0401.143917.7
82388.2381.143817.2
82408.2401.144018
83388.3381.144018
83408.3401.144018
98389.8381.144219.1
1033810.3381.145022.7

*1” permeate tube extensions (0.75” OD) Note: Different diameters are available. Specifications are subject to change without notice.

Membrane Area (sq. ft.)

Element Model No.Feed Spacer (in mils) 24Feed Spacer (in mils) 31Feed Spacer (in mils) 46Feed Spacer (in mils) 65Feed Spacer (in mils) 80
1.8”
1812FN/A3.6N/AN/AN/A
2.5”
2519151310N/AN/A
2540F342922N/AN/A
2540M353023N/AN/A
3.8”
38388572584638
3838.758674594739
385010084705246
3938.7510289695347
4.3”
43339986665344
433510591715647
4335.510793725748
433610894735849
4338115100776252
5.8”
583821018414711496
6.3”
63241501341078370
6338246220176136115
6.4”
64241571401128374
6438258230184136122
7.8”
7824242210166132110
7838396344273216180
8”
8038414368287225189
8040414368287225189
8238441384302238201
8240441384302238201
8338450400311245207
8340450400311245207
9.8”
9838N/A564440351296
10”
10338N/A620492386326

Recommended Element Cross Flow Rate

ElementFeed Spacer (in mils) 24 m³/hr (gpm)Feed Spacer (in mils) 31 m³/hr (gpm)Feed Spacer (in mils) 46 m³/hr (gpm)Feed Spacer (in mils) 65 m³/hr (gpm)Feed Spacer (in mils) 80 m³/hr (gpm)
1.8”
1 (4)1 (5)1 (6)2 (7)2 (7)
2.5”
2 (9)2 (10)3 (11)3 (12)3 (13)
3.8”
5 (22)6 (25)7 (29)8 (33)8 (35)
4.3”
6 (29)7 (32)9 (38)10 (44)10 (46)
5.8”
12 (51)13 (59)16 (69)18 (78)19 (83)
6.3”
15 (65)17 (74)20 (88)22 (99)24 (105)
8”
21 (94)24 (107)29 (128)33 (143)35 (154)
10”
42 (184)48 (213)57 (250)64 (283)68 (299)

The recommended cross flow rate will be subject to differential pressure limitations and specific applications.

Standard Series Benefits

  • Conforms to 3-A, FDA, and USDA sanitary standards
  • Widest range of UF MWCO’s available
  • Good resistance to pH and temperature
  • High resistance to fouling
  • Customizable dimensions for unique housings

Common Applications

  • Color removal
  • Antibiotic concentration
  • Protein & polypeptide concentration

Technical Notes

For element sizes not listed, or to design an element to fit exact needs (outer diameter, inner diameter, length, or with/without controlled bypass tail), please consult Synder Filtration. Additional feed spacers are also available. Trials should be conducted to determine optimal application conditions.


Disclaimer: This summary is generated from an extracted text and may not include all figures, footnotes, or the latest revisions present in the complete OEM PDF datasheet. For contractual data and complete specifications, the official OEM PDF revision used on the project must be consulted.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.