Datasheet summary
XT PHT PES 1kDa
Engineering summary from PDF text extraction for XT PHT PES 1kDa. Verify every value with the OEM datasheet.
Summary
Product identification
Synder Filtration's PHT Series of Ultrafiltration Elements offer exceptional physical and chemical durability. This document describes the XT (PES 1kDa) PHT Sanitary Ultrafiltration Spiral-Wound Element.
PHT Series Benefits
- Conforms to 3-A, FDA, and USDA sanitary standards
- Elimination of chlorine during CIP with hot sanitation
- High resistance to pH, temperature, & fouling
- Customizable dimensions for unique housings
Common applications
- Color removal
- Antibiotic concentration
- Protein & polypeptide concentration
Operating limits
Recommended Operating Parameters
- Maximum Temperature: 60°C (140°F)
- pH Range @ Max Temperature: 2-10
- pH Range @ Ambient Temperature: 2-10.5
Pressure
- Max Inlet Pressure: 120 PSI (8.3 Bar)
- Min Outlet Pressure: 10 PSI (0.7 Bar)
- Max Differential Pressure per Element: 18 PSI (1.2 Bar)
- Max Permeate Backpressure: 5 PSI (0.3 Bar)
Note: Soft start on boost pumps required to minimize pressure/flow shocks to elements.
Cleaning parameters
- Maximum Temperature (Short term <30min): 85°C (185°F)
- pH Range @ Max Temperature: 2-11
- pH Range @ Ambient Temperature: 2-12.5
Chlorine
- Free Chlorine During Operation: 0 Norm ppm, <0.1 Max ppm
- Chlorine During CIP at pH 10.8-11.0 and 50°C: 150 Norm ppm, 180 Max ppm
Note: Maximum chlorine exposure for all elements is 30 minutes per day at pH and temperature conditions listed above.
Feed water
Dairy Product Total Solids Limits
| Feed Spacer (in mils) | 31 | 46 | 65 | 80 |
|---|---|---|---|---|
| Sweet Whey Max. T.S. | 15 | 25 | 28 | 30 |
| Acid Whey Max. T.S. | 15 | 24 | 26 | 28 |
| Skim Milk Max. T.S. | 14 | 24 | 26 | 28 |
| Whole Milk Max. T.S. | 15 | 30 | 33 | 35 |
Note: Trials should be made to determine temperature and viscosity effects.
Mechanical / hydraulic
Element Dimensions
| Element Diameter (B) in | Model No. | Length (A) in | P.W.T. ID |
|---|---|---|---|
| 1.8” | 1812F | 12 | 0.63 |
| 2.5” | 2519 | 19.25 | 0.63 |
| 2540F | 40 | 0.63 | |
| 2540M* | 38 | 0.75 | |
| 3.8” | 3838 | 38 | 0.83 |
| 3838.75 | 38.75 | 0.83 | |
| 3850 | 50 | 0.83 | |
| 3938.75 | 38.75 | 0.63 | |
| 4.3” | 4333 | 33 | 0.83 |
| 4335 | 35 | 0.83 | |
| 4335.5 | 35.5 | 0.83 | |
| 4336 | 36 | 0.83 | |
| 4338 | 38 | 0.83 | |
| 5.8” | 5838 | 38 | 1.14 |
| 6.3” | 6338 | 38 | 1.14 |
| 6324 | 24 | 1.14 | |
| 6.4” | 6438 | 38 | 1.14 |
| 6424 | 24 | 1.14 | |
| 7.8” | 7838 | 38 | 1.14 |
| 7824 | 24 | 1.14 | |
| 8” | 8038 | 38 | 1.14 |
| 8040 | 40 | 1.14 | |
| 8238 | 38 | 1.14 | |
| 8240 | 40 | 1.14 | |
| 8338 | 38 | 1.14 | |
| 8340 | 40 | 1.14 | |
| 9.8” | 9838 | 38 | 1.14 |
| 10” | 10338 | 38 | 1.14 |
*1” permeate tube extensions (0.75” OD)
Element Descriptions
| Model No. | OD (in.) | L (in.) | ID* (in.) | Weight (lb) | Weight (kg) |
|---|---|---|---|---|---|
| 1812F | 1.8 | 12 | 0.63 | 1.0 | 0.5 |
| 2519 | 2.5 | 19.25 | 0.63 | 2 | 0.9 |
| 2540F | 2.5 | 40 | 0.63 | 4 | 1.8 |
| 2540M* | 2.5 | 38 | 0.75 | 4 | 1.8 |
| 3838 | 3.8 | 38 | 0.83 | 10 | 4.5 |
| 3838.75 | 3.8 | 38.75 | 0.83 | 10 | 4.5 |
| 3850 | 3.8 | 50 | 0.83 | 13 | 5.9 |
| 3938.75 | 4.0 | 38.75 | 0.63 | 10 | 4.5 |
| 4333 | 4.3 | 33 | 0.83 | 11 | 5.0 |
| 4335 | 4.3 | 35 | 0.83 | 11 | 5.2 |
| 4335.5 | 4.3 | 35.5 | 0.83 | 11 | 5.2 |
| 4336 | 4.3 | 36 | 0.83 | 11 | 5.2 |
| 4338 | 4.3 | 38 | 0.83 | 12 | 5.4 |
| 5838 | 5.8 | 38 | 1.14 | 15 | 7 |
| 6338 | 6.3 | 38 | 1.14 | 16 | 7 |
| 6324 | 6.3 | 24 | 1.14 | 17 | 7.7 |
| 6438 | 6.4 | 38 | 1.14 | 29 | 13.2 |
| 6424 | 6.4 | 24 | 1.14 | 18 | 8.2 |
| 7838 | 7.8 | 38 | 1.14 | 40 | 18.2 |
| 7824 | 7.8 | 24 | 1.14 | 26 | 11.8 |
| 8038 | 8.0 | 38 | 1.14 | 38 | 17.2 |
| 8040 | 8.0 | 40 | 1.14 | 39 | 17.7 |
| 8238 | 8.2 | 38 | 1.14 | 38 | 17.2 |
| 8240 | 8.2 | 40 | 1.14 | 40 | 18 |
| 8338 | 8.3 | 38 | 1.14 | 40 | 18 |
| 8340 | 8.3 | 40 | 1.14 | 40 | 18 |
| 9838 | 9.8 | 38 | 1.14 | 42 | 19.1 |
| 10338 | 10.3 | 38 | 1.14 | 50 | 22.7 |
*1” permeate tube extensions (0.75” OD) Note: Different diameters are available. Specifications are subject to change without notice.
Recommended Element Cross Flow Rate
The recommended cross flow rate will be subject to differential pressure limitations and specific applications.
| Element | Feed Spacer (in mils) | 24 | 31 | 46 | 65 | 80 |
|---|---|---|---|---|---|---|
| 1.8” | m³/hr | 1 | 1 | 1 | 2 | 2 |
| gpm | 4 | 5 | 6 | 7 | 7 | |
| 2.5” | m³/hr | 2 | 2 | 3 | 3 | 3 |
| gpm | 9 | 10 | 11 | 12 | 13 | |
| 3.8” | m³/hr | 5 | 6 | 7 | 8 | 8 |
| gpm | 22 | 25 | 29 | 33 | 35 | |
| 4.3” | m³/hr | 6 | 7 | 9 | 10 | 10 |
| gpm | 29 | 32 | 38 | 44 | 46 | |
| 5.8” | m³/hr | 12 | 13 | 16 | 18 | 19 |
| gpm | 51 | 59 | 69 | 78 | 83 | |
| 6.3” | m³/hr | 15 | 17 | 20 | 22 | 24 |
| gpm | 65 | 74 | 88 | 99 | 105 | |
| 8” | m³/hr | 21 | 24 | 29 | 33 | 35 |
| gpm | 94 | 107 | 128 | 143 | 154 | |
| 10” | m³/hr | 42 | 48 | 57 | 64 | 68 |
| gpm | 184 | 213 | 250 | 283 | 299 |
Membrane Area (sq. ft.)
| Element Model No. | Feed Spacer (in mils) | 24 | 31 | 46 | 65 | 80 |
|---|---|---|---|---|---|---|
| 1812F | N/A | 3.6 | N/A | N/A | N/A | |
| 2519 | 15 | 13 | 10 | N/A | N/A | |
| 2540F | 34 | 29 | 22 | N/A | N/A | |
| 2540M | 35 | 30 | 23 | N/A | N/A | |
| 3838 | 85 | 72 | 58 | 46 | 38 | |
| 3838.75 | 86 | 74 | 59 | 47 | 39 | |
| 3850 | 100 | 84 | 70 | 52 | 46 | |
| 3938.75 | 102 | 89 | 69 | 53 | 47 | |
| 4333 | 99 | 86 | 66 | 53 | 44 | |
| 4335 | 105 | 91 | 71 | 56 | 47 | |
| 4335.5 | 107 | 93 | 72 | 57 | 48 | |
| 4336 | 108 | 94 | 73 | 58 | 49 | |
| 4338 | 115 | 100 | 77 | 62 | 52 | |
| 5838 | 210 | 184 | 147 | 114 | 96 | |
| 6324 | 150 | 134 | 107 | 83 | 70 | |
| 6338 | 246 | 220 | 176 | 136 | 115 | |
| 6424 | 157 | 140 | 112 | 83 | 74 | |
| 6438 | 258 | 230 | 184 | 136 | 122 | |
| 7824 | 242 | 210 | 166 | 132 | 110 | |
| 7838 | 396 | 344 | 273 | 216 | 180 | |
| 8038 | 414 | 368 | 287 | 225 | 189 | |
| 8040 | 414 | 368 | 287 | 225 | 189 | |
| 8238 | 441 | 384 | 302 | 238 | 201 | |
| 8240 | 441 | 384 | 302 | 238 | 201 | |
| 8338 | 450 | 400 | 311 | 245 | 207 | |
| 8340 | 450 | 400 | 311 | 245 | 207 | |
| 9838 | N/A | 564 | 440 | 351 | 296 | |
| 10338 | N/A | 620 | 492 | 386 | 326 |
Disclaimer
This summary is based on the provided text extract and may not include all figures, footnotes, or the latest revisions. For contractual data, please refer to the official OEM PDF revision used on your project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.