Datasheet summary
Super-CELL
Engineering summary from PDF text extraction for Super-CELL. Verify every value with the OEM datasheet.
Summary
Product Identification
The SuperCELL is a heavy duty, light weight, one piece C-Cell anode cell designed for optimum paint coverage in large electrocoat paint tanks. It offers efficiency and performance with 100% of the cell facing the job, making it an economic option for large volume paint tanks.
Mechanical / Hydraulic
The SuperCELL features a one-piece anode cell design:
- Designed for ease in lifting and connecting to the power cable.
- Weighs less than 1/3 of a standard flat cell.
- No welds below the anolyte fluid to prevent failure due to submerged mechanical or welded connections.
- Made from 10 gauge or 3/16” thick 316L stainless steel.
Electrode Sizes:
- Effective area 1.3 sq. ft/ft, Standard Size
- Effective area 1.0 sq. ft/ft, low profile size
- Effective area 1.5 sq. ft/ft, high surface area size
Materials of Construction
- Heavy Duty molded FRP back and PVC body
- FRP, PVC, and SS hardware
- PVC back on Membrane Module
- Polypropylene mesh membrane protector
Electrode Material:
- 316L Stainless Steel
Performance
Test data comparing a Standard Flat Cell (16 Sq. Ft) to an Arelco Synder SuperCELL (7.11 Sq. Ft):
| Parameter | Standard Flat Cell (16 Sq. Ft) | Arelco Synder SuperCELL (7.11 Sq. Ft) |
|---|---|---|
| Minimum Output | 29 amps | 23 amps |
| Maximum Output | 62 amps | 44 amps |
| Output Coulombs (in 40 seconds) | 1800 | 1358 |
| Average Output (per sq. ft/min) | 168 coulombs | 287 coulombs |
| Average Distance of Effective Coating | 15.4 ft | 20.6 ft |
Tests were conducted during actual production where data was taken from both flat and Synder 1.3 SuperCELLs of the same length positioned adjacently from one another.
Features and Benefits
- Lower Operating Costs: 70% increase in amps per square foot and subsequent 50% savings in electrical power usage.
- Better Coverage: A greater range of electrical “throw angles” significantly improves coating quality and coverage in hard-to-reach areas, and allows the anode to start painting sooner in monorail systems.
- Easy To Use & Maintain: Heavy duty, light weight, and one piece design for easy lifting and simple power cable connections.
- Flexibility For Your Tank: Available in four different sizes, including a low profile option for tanks with limited clearance between the part and tank wall.
Standard Accessories
- Flow meters
- Supply and return tubing
- Stainless Steel mounting clamps
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original OEM PDF datasheet. For contractual data, please refer to the specific OEM PDF revision used on the project.