Back to Toray Membranes
Toray logo

Datasheet summary

NHPA050F

Engineering summary from PDF text extraction for NHPA050F. Verify every value with the OEM datasheet.

Summary

Product Identification

The NHPA050 Series are submerged flat-sheet membrane bioreactor (MBR) products designed for biological wastewater treatment.

The NHPA series incorporates thin membrane sheets for improved flexibility, allowing more membrane area per footprint. The NHPA series also features adjustable module configurations to suit various situations regarding water capacity, height, and width, while maintaining operational features of the NHP series.

  • Model: TFS-50080 (Flat Sheet Element)
  • Series: NHPA050

Product Specifications

Flat Sheet Element

  • Nominal Pore Size: 0.08 µm
  • Materials - Membrane: PVDF and PET non-woven fiber
  • Materials - Nozzle: PE
  • Effective Membrane Area: 0.7 m² (7.5 ft²)
  • Dimensions (w x l x thk): 480 x 800 x 1.8 mm (18.9 x 31.5 x 0.07 in.)
  • Weight (dry / wet reference): 0.25 / 0.5 kg (0.6 / 1.1 lbs.)

Module Characteristics

  • Structure: Cassette x Deck
  • Measurements include filtrate header and air diffuser pipes.
ModelNo. of ElementsStructureTotal Membrane Area m² (ft²)Dimensions (w x l x h) MillimetersDimensions (w x l x h) Inches
ECS035 (Cassette)5035 (377)485 x 440 x 82019.1 x 17.3 x 32.3
NHPA050-1F501 x 135 (377)738 x 630 x 1,40429.5 x 24.8 x 55.3

Module Dry Weight

  • ECS035 (Cassette):
    • Cassette / Element block: 17 kg (37 lbs.)
  • NHPA050-1F:
    • Aeration block: 20 kg (44 lbs.)
    • Cassette / Element block: 50 kg (110 lbs.)
    • Module: 70 kg (154 lbs.)

Applications

  • Sewage wastewater
  • Industrial wastewater
  • Food processing wastewater
  • Sludge thickening process

Materials

  • Frame: 304 stainless steel (316 SS optional)
  • Manifold: Polypropylene
  • Air Diffuser: EPDM rubber/PVC/304SS

Connections

  • Manifold: ANSI 1 1/2 inch flange using M12 bolts/nuts (one flange per each deck)
  • Air Diffuser: NPT 1 1/4 inch screw (one connection per Aeration block)

Operating Limits

  • Temperature: 5–40 °C (41–104 °F)
  • pH of Liquid³: 5–10 (³Except when chemical cleaning with designated chemical agents)
  • Mixed Liquor Suspended Solids: Not higher than 18,000 mg/L
  • Transmembrane Pressure: Not higher than 20 kPa (2.9 psi)
  • Cleaning Chemical Feed Pressure: Not higher than 10 kPa (1.45 psi)

Cleaning Chemicals and Concentrations

  • Sodium hypochlorite: 2,000–6,000 mg/L (10 < pH < 12)
  • Oxalic acid: 0.5–1.0 wt%
  • Citric acid: 1.0–3.0 wt%

Scouring Air Flow Rate

  • NHPA050-1F: 330–430 NL/min/Module (12–15 ft³/min/Module)

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.