Datasheet summary
NHPA100C
Engineering summary from PDF text extraction for NHPA100C. Verify every value with the OEM datasheet.
Summary
Product identification
- Series: NHPA100 Series
- Product Type: Submerged Flat-sheet Membrane Bioreactor (MBR)
- Application: Biological Wastewater Treatment
- Flat Sheet Element Model: TSP-50080
- Module Models: ECS035 (Cassette), NHPA100-1C
- Document Reference: 01-MB2-12-221010
Mechanical / hydraulic
- Flat Sheet Element (Model: TSP-50080)
- Nominal Pore Size: 0.08 µm
- Materials: PVDF and PET non-woven fiber (Membrane), PE (Nozzle)
- Effective Membrane Area: 0.7 m² (7.5 ft²)
- Dimensions (w x l x thk): 480 x 800 x 1.8 mm (18.9 x 31.5 x 0.07 in.)
- Weight (dry / wet reference): 0.25 / 0.5 kg (0.6 / 1.1 lbs.)
- Module Characteristics
- ECS035 (Cassette)
- No. of Elements: 50
- Total Membrane Area: 35 m² (377 ft²)
- Dimensions (w x l x h): 485 x 440 x 820 mm (19.1 x 17.3 x 32.3 in.)
- Dry Weight (Cassette / Element block): 17 kg (37 lbs.)
- NHPA100-1C
- No. of Elements: 100
- Structure: 2x 1 Cassette x Deck
- Total Membrane Area: 70 m² (754 ft²)
- Dimensions (w x l x h)*: 738 x 1,130 x 1,404 mm (29.5 x 44.5 x 55.3 in.) *Measurements include filtrate header and air diffuser pipes.
- Dry Weight:
- Aeration block: 30 kg (66 lbs.)
- Cassette / Element block: 80 kg (176 lbs.)
- Module: 110 kg (243 lbs.)
- Scouring Air Flow Rate: 670–1,340 NL/min/Module (24–48 ft³/min/Module)
- Note: Air volume is measured at 0 °C and 101.325 kPa (1 atm).
- ECS035 (Cassette)
- Materials (Module)
- Frame: 304 stainless steel (316 SS optional)
- Manifold: Polypropylene
- Air Diffuser: 304 stainless steel (316 SS optional)
- Connections
- Manifold: ANSI 1 1/2 inch flange using M12 bolts/nuts (one flange per each deck)
- Air Diffuser: ANSI 1 1/4 inch flange using M12 bolts/nuts (two flanges per Aeration block)
Operating limits
- Temperature: 5–40 °C (41–104 °F)
- pH of Liquid: 5–10 (except when chemical cleaning with designated chemical agents)
- Mixed Liquor Suspended Solids: Not higher than 18,000 mg/L
- Transmembrane Pressure: Not higher than 20 kPa (2.9 psi)
- Cleaning Chemical Feed Pressure: Not higher than 10 kPa (1.45 psi)
- Cleaning Chemicals and Concentrations
- Sodium hypochlorite: 2,000–6,000 mg/L (10 < pH < 12)
- Oxalic acid: 0.5–1.0 wt%
- Citric acid: 1.0–3.0 wt%
Feed water
- Applications:
- Sewage wastewater
- Industrial wastewater
- Food processing wastewater
- Sludge thickening process
Disclaimer: The information provided is based on the extracted text. This summary may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.