NHPA100F

Engineering summary from PDF text extraction for NHPA100F. Verify every value with the OEM datasheet.

Summary

Product identification

The NHPA100 Series comprises Submerged Flat-sheet Membrane Bioreactor (MBR) elements designed for biological wastewater treatment.

  • Product Series: NHPA100 Series
  • Document ID: 01-MB2-15-221010

Product characteristics

Flat Sheet Element: TFS-50080

  • Model: TFS-50080
  • Nominal Pore Size: 0.08 µm
  • Effective Membrane Area: 0.7 m² (7.5 ft²)
  • Dimensions (w x l x thk): 480 x 800 x 1.8 mm (18.9 x 31.5 x 0.07 in.)
  • Weight: dry / wet (reference): 0.25 / 0.5 kg (0.6 / 1.1 lbs.)

Module Characteristics

ModelNo. of ElementsStructure: Cassette x DeckTotal Membrane Area m² (ft²)Dimensions (w x l x h) MillimetersDimensions (w x l x h) Inches
ECS035 (Cassette)5035 (377)485 x 440 x 82019.1 x 17.3 x 32.3
NHPA100-1F1002x 170 (754)738 x 1,115 x 1,40429.5 x 43.9 x 55.3

*Measurements include filtrate header and air diffuser pipes.

Module Dry Weight - kg (lbs.)

ModelAeration blockCassette / Element blockModule
ECS035 (Cassette)17 (37)
NHPA100-1F30 (66)80 (176)110 (243)

The NHPA series features thin membrane sheets for improved flexibility, allowing more membrane area per footprint. Its module configuration can be adjusted to suit various situations regarding water capacity, height, and width.

Applications

  • Sewage wastewater
  • Industrial wastewater
  • Food processing wastewater
  • Sludge thickening process

Materials

  • Membrane: PVDF and PET non-woven fiber
  • Nozzle: PE
  • Frame: 304 stainless steel (316 SS optional)
  • Manifold: Polypropylene
  • Air Diffuser: EPDM rubber/PVC/304SS

Connections

  • Manifold: ANSI 1 1/2 inch flange using M12 bolts/nuts (one flange per each deck)
  • Air Diffuser: NPT 1 1/4 inch screw (one connection per Aeration block)

Operating limits

  • Temperature: 5–40 °C (41–104 °F)
  • pH of Liquid: 5–10 (except during chemical cleaning with designated agents)
  • Mixed Liquor Suspended Solids: Not higher than 18,000 mg/L
  • Transmembrane Pressure: Not higher than 20 kPa (2.9 psi)
  • Cleaning Chemical Feed Pressure: Not higher than 10 kPa (1.45 psi)

Cleaning Chemicals and Concentrations

  • Sodium hypochlorite: 2,000–6,000 mg/L (10 < pH < 12)
  • Oxalic acid: 0.5–1.0 wt%
  • Citric acid: 1.0–3.0 wt%

Scouring Air Flow Rate

  • NHPA100-1F: 670–870 NL/min/Module (24–31 ft³/min/Module)