Back to Toray Membranes
Toray logo

Datasheet summary

NHPA150F

Engineering summary from PDF text extraction for NHPA150F. Verify every value with the OEM datasheet.

Summary

Product Identification

The NHPA150 Series is a Submerged Flat-sheet Membrane Bioreactor (MBR) designed for Biological Wastewater Treatment. This series incorporates thin membrane sheets for improved flexibility, allowing more membrane area per footprint. Its module configuration can be adjusted to suit various situations regarding water capacity, height, and width, while maintaining the operational features of the current NHP series.

Applications

  • Sewage wastewater
  • Industrial wastewater
  • Food processing wastewater
  • Sludge thickening process

Mechanical / Hydraulic

Flat Sheet Element (Model TFS-50080)

  • Nominal Pore Size: 0.08 µm
  • Membrane Material: PVDF and PET non-woven fiber
  • Nozzle Material: PE
  • Effective Membrane Area: 0.7 m² (7.5 ft²)
  • Dimensions (w x l x thk): 480 x 800 x 1.8 mm (18.9 x 31.5 x 0.07 in.)
  • Weight (dry / wet, reference): 0.25 / 0.5 kg (0.6 / 1.1 lbs.)

Module Characteristics

The modules include the filtrate header and air diffuser pipes in their measurements.

  • ECS035 (Cassette)
    • No. of Elements: 50
    • Total Membrane Area: 35 m² (377 ft²)
    • Dimensions (w x l x h): 485 x 440 x 820 mm (19.1 x 17.3 x 32.3 in.)
    • Dry Weight (Cassette / Element block): 17 kg (37 lbs.)
  • NHPA150-1F
    • No. of Elements: 150
    • Structure: 3 x 1 Cassette x Deck
    • Total Membrane Area: 105 m² (1,130 ft²)
    • Dimensions (w x l x h): 763 x 1,718 x 1,404 mm (30.3 x 67.3 x 55.3 in.)
    • Dry Weight (Aeration block / Cassette / Element block / Module): 60 (132) / 115 (254) / 175 (386) kg (lbs.)
  • NHPA150-2F
    • No. of Elements: 300
    • Structure: 3 x 2 Cassette x Deck
    • Total Membrane Area: 210 m² (2,260 ft²)
    • Dimensions (w x l x h): 763 x 1,718 x 2,304 mm (30.3 x 67.3 x 90.7 in.)
    • Dry Weight (Aeration block / Cassette / Element block / Module): 60 (132) / 230 (507) / 290 (639) kg (lbs.)
  • NHPA150-3F
    • No. of Elements: 450
    • Structure: 3 x 3 Cassette x Deck
    • Total Membrane Area: 315 m² (3,391 ft²)
    • Dimensions (w x l x h): 763 x 1,718 x 3,204 mm (30.3 x 67.3 x 126.1 in.)
    • Dry Weight (Aeration block / Cassette / Element block / Module): 60 (132) / 345 (761) / 405 (893) kg (lbs.)
  • NHPA150-4F
    • No. of Elements: 600
    • Structure: 3 x 4 Cassette x Deck
    • Total Membrane Area: 420 m² (4,521 ft²)
    • Dimensions (w x l x h): 763 x 1,718 x 4,104 mm (30.3 x 67.3 x 161.6 in.)
    • Dry Weight (Aeration block / Cassette / Element block / Module): 60 (132) / 460 (1,014) / 520 (1,146) kg (lbs.)

Materials

  • Frame: 304 stainless steel (316 SS optional)
  • Manifold: Polypropylene
  • Air Diffuser: EPDM rubber/PVC/304SS

Connections

  • Manifold: ANSI 1 1/2 inch flange using M12 bolts/nuts (One flange per each deck)
  • Air Diffuser: NPT 1 1/2 inch screw (Two connections per Aeration block)

Operating Limits

  • Temperature: 5–40 °C (41–104 °F)
  • pH of Liquid: 5–10 (Except when chemical cleaning with designated chemical agents.)
  • Mixed Liquor Suspended Solids: Not higher than 18,000 mg/L
  • Transmembrane Pressure: Not higher than 20 kPa (2.9 psi)
  • Cleaning Chemical Feed Pressure: Not higher than 10 kPa (1.45 psi)

Cleaning Chemicals and Concentrations

  • Sodium hypochlorite: 2,000–6,000 mg/L (10 < pH < 12)
  • Oxalic acid: 0.5–1.0 wt%
  • Citric acid: 1.0–3.0 wt%

Scouring Air Flow Rate

  • NHPA150-1F: 1,000–1,300 NL/min/Module (35–46 ft³/min/Module)
  • NHPA150-2F: 1,000–1,300 NL/min/Module (35–46 ft³/min/Module)
  • NHPA150-3F: 1,000–1,300 NL/min/Module (35–46 ft³/min/Module)
  • NHPA150-4F: 1,000–1,300 NL/min/Module (35–46 ft³/min/Module)

Note: Air volume is specified at 0 °C and 101.325 kPa (1 atm). The air supply equipment, such as the blower, should be designed based on standard operating conditions.


Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. For contractual data, please refer to the specific OEM PDF revision used for your project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.