Back to Toray Membranes
Toray logo

Datasheet summary

SC-2201

Engineering summary from PDF text extraction for SC-2201. Verify every value with the OEM datasheet.

Summary

Product identification

  • MODEL: SC-2201
  • Membrane Type: Modified Cellulose Acetate
  • Element Configuration: Spiral Wound

Performance Specification

  • Salt Rejection: 95.0 % (92.5 % minimum*)
  • Product Flow Rate: 35.2 m³/day (9300 gpd) (30.4 m³/day (8040 gpd) minimum*)
  • Notes:
    • *For any single element

Test Conditions (for Performance Specification)

  • Feed Water Pressure: 3.0 MPa (440 psi)
  • Feed Water Temperature: 25 °C (77 °F)
  • Feed Water Concentration: 1,500 mg/L as NaCl
  • Brine Flow Rate: 80 L/min. (21 gpm)
  • Feed Water pH: 6

Operating Limits

The recommended design range applies to operational and design conditions with minimal fouling and scaling. Operating outside this range may reduce effective membrane life.

  • Recommended Design Conditions:
    • Feed Water Pressure: 3.0 MPa (430 psi)
    • Feed Water Temperature: 30 °C (86 °F)
    • Feed Water Turbidity (SDI): 4 (SDI is Silt Density Index measured according to ASTM D4189.)
    • Feed Water Chlorine Concentration: 0.1 – 0.7 mg/L (Feed and brine water must meet this range.)
    • Feed Water pH Range, Continuous Operation: 4 – 6.5 (Feed and brine water must meet this range.)
    • Feed Water pH Range, Chemical Cleaning: 3 – 8.5 (Cleaning chemicals shall follow Toray's technical bulletins.)
    • Feed Flow Rate per Vessel: 200 L/min. (52.8 gpm)
    • Brine Flow Rate per Vessel: 40 L/min. (10.6 gpm)
    • Brine/Permeate Flow Ratio: 6 (Ratio at last element. This figure is reducible when there is less possibility of fouling and scaling.)
    • Pressure Drop (per Element): 1 kg/cm² (14 psi)
    • Pressure Drop (per Vessel): 2 kg/cm² (29 psi)
  • Maximum Operating Conditions:
    • Maximum Feed Water Pressure: 4.1 MPa (600 psi)
    • Maximum Feed Water Temperature: 40 °C (104 °F)
  • Cleaning and Sterilization:
    • Element(s) must be cleaned when pressure drop increases up to 1.5 times of initial value.
    • Sterilization must follow guidances in Toray's technical bulletin.
    • High flux operation on feed water turbidity greater than 3 or 4 SDI generally results in frequent cleaning requirements. Operating pressure should be selected to maintain the flux rate, or permeate flow rate per single element.

Mechanical / hydraulic

  • Dimensions: The diagram illustrates the element with an overall length of 1016 mm. It indicates feed water and concentrated brine flow directions, and permeate outlet. Other marked dimensions are 11 mm and 22 mm, which likely refer to internal or connector specifications. All dimensions are shown in millimeters. See the official PDF for exact tabulated values and a detailed diagram.

Disclaimer: This summary is based on the provided text extract and may not include all figures, footnotes, or the latest revisions from the original OEM PDF datasheet. For contractual data, please refer to the specific OEM PDF revision used on the project.