Datasheet summary
SC-4101
Engineering summary from PDF text extraction for SC-4101. Verify every value with the OEM datasheet.
Summary
Product identification
- Model: SC-4101
- Membrane Type: Modified Cellulose Acetate
- Element Configuration: Spiral Wound
Product water
- Salt Rejection: 97.0 % (96.0 % minimum for any single element)
- Product Flow Rate: 6.8 m³/day (1800 gpd) (5.5 m³/day (1460 gpd) minimum for any single element)
Operating limits
- Performance Test Conditions:
- Feed Water Pressure: 3.0 MPa (440 psi)
- Feed Water Temperature: 25 °C (77 °F)
- Feed Water Concentration: 1500 mg/L as NaCl
- Brine Flow Rate: 20 L/min. (5.3 gpm)
- Feed Water pH: 6
- Recommended Design Conditions:
- Feed Water Pressure: 30 kg/cm² (430 psi)
- Maximum Feed Water Pressure: 4.1 MPa (600 psi)
- Feed Water Temperature: 30 °C (86 °F)
- Feed Water Turbidity (SDI): 4
- SDI is measured according to ASTM D4189.
- High flux operation with feed water turbidity greater than 3 or 4 SDI generally results in frequent cleaning requirements.
- Feed and brine water must meet this range.
- Feed Water Chlorine Concentration: 0.1 - 0.7 mg/L
- Feed Water pH Range, Continuous Operation: 4 - 6.5
- Feed Water pH Range, Chemical Cleaning: 3 - 8.5
- Feed Flow Rate per Vessel: 50 L/min. (13.2 gpm)
- Brine Flow Rate per Vessel: 10 L/min. (2.6 gpm)
- Brine/Permeate Flow Ratio: 6 (ratio at last element; reducible when there is less possibility of fouling and scaling)
- Pressure Drop (per Element): 0.10 MPa (14 psi)
- Pressure Drop (per Vessel): 0.20 MPa (29 psi)
- Cleaning: Element(s) must be cleaned when pressure drop increases up to 1.5 times of initial value.
- Sterilization: Must follow guidances in Toray's technical bulletin.
- Note: Operating outside the recommended design range may reduce the effective membrane life.
- Feed Water Pressure: 30 kg/cm² (430 psi)
Mechanical / hydraulic
- Dimensions:
- Overall Length: 1016 mm
- Other dimensions observed from diagram: 15 mm, 22 mm.
- See the official PDF for detailed dimensional diagrams illustrating Feed (F), Permeate, and Brine (B) flow directions. All dimensions are shown in millimeters.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the OEM PDF. Contractual data must match the specific OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.