SC-6101
Engineering summary from PDF text extraction for SC-6101. Verify every value with the OEM datasheet.
Summary
Product identification
- Model: SC-6101
- Description: High rejection and chlorine resistant RO element
- Membrane Type: Modified Cellulose Acetose
- Element Configuration: Spiral Wound
Performance Specification
- Salt Rejection: 98.0 % (97.0 % minimum*)
- Product Flow Rate: 5.3 m³/day (1400 gpd) (4.3 m³/day (1130 gpd) minimum*)
*For any single element
Test Conditions
- Feed Water Pressure: 3.0 MPa (440 psi)
- Feed Water Temperature: 25 °C (77 °F)
- Feed Water Concentration: 1500 mg/L as NaCl
- Brine Flow Rate: 20 L/min (5.3 gpm)
- Feed Water pH: 6
Operating Limits
- Design Conditions (Recommended):
- Feed Water Pressure: 30 kg/cm² (430 psi)
- Feed Water Temperature: 30 °C (86 °F)
- Feed Water Turbidity (SDI): 4 (Note: High flux operation on feed water turbidity greater than 3 or 4 SDI generally results in frequent cleaning requirements.)
- Feed Water Chlorine Concentration: 0.1 - 0.7 mg/L
- Feed Water pH Range (Continuous Operation): 4 - 6.5
- Feed Water pH Range (Chemical Cleaning): 3 - 8.5
- Feed Flow Rate per Vessel: 45 L/min (11.9 gpm)
- Brine Flow Rate per Vessel: 10 L/min (2.6 gpm)
- Brine/Permeate Flow Ratio: 6 (Note: This figure is reducible when there is less possibility of fouling and scaling.)
- Maximum Feed Water Pressure: 4.1 MPa (600 psi)
Feed water
- Refer to "Performance Specification - Test Conditions" and "Operating Limits - Design Conditions" for detailed parameters.
- SDI = Silt Density Index measured according to ASTM D4189.
- Feed and brine water must meet the specified ranges.
Product water
- Refer to "Performance Specification" for detailed parameters.
Mechanical / hydraulic
- Dimensions:
- Length: 1016 mm
- Outer Diameter: 101 mm
- Permeate Tube Nominal Diameter: 15 mm
- All dimensions shown in millimeters.
- Pressure Drop:
- Per Element: 0.10 MPa (14 psi)
- Per Vessel: 0.20 MPa (29 psi) (Note: Element(s) must be cleaned when pressure drop increases up to 1.5 times of initial value.)