Datasheet summary

TM720L-430

Engineering summary from PDF text extraction for TM720L-430. Verify every value with the OEM datasheet.

Summary

Product identification

  • Model: SU-710L
  • Membrane Type: Cross Linked Fully Aromatic Polyamide Composite
  • Element Configuration: Spiral Wound
  • Membrane Surface Area: Nominal 7 m² (75 ft²)

Performance Specification (Test Conditions)

Performance is an average value for 100 elements after 1 hour of operation under the following conditions:

  • Feed Water Pressure: 1.0 MPa (150 psi)
  • Feed Water Temperature: 25 °C (77 °F)
  • Feed Water Concentration: 1500 mg/L as NaCl
  • Brine Flow Rate: 20 L/min. (5.3 gpm)
  • Feed Water pH: 6.5

Product water

  • Salt Rejection: 99.0 % (98.0 % minimum for any single element)
  • Product Flow Rate: 5.5 m³/day (1500 gpd) (5.0 m³/day (1320 gpd) minimum for any single element)

Operating limits / Design Conditions

These conditions are recommended for operation with less fouling and scaling; operating outside these ranges may reduce membrane life.

  • Recommended Feed Water Pressure: 1.5 MPa (220 psi)
  • Maximum Feed Water Pressure: 4.1 MPa (600 psi)
  • Recommended Feed Water Temperature: 35 °C (95 °F)
  • Maximum Feed Water Temperature: 45 °C (113 °F)
  • Feed Water Turbidity (SDI): 4 (High flux operation with SDI > 3 or 4 may require frequent cleaning.)
  • Feed Water pH Range, Continuous Operation: 3 – 9 (Feed and brine water must meet this range.)
  • Feed Water pH Range, Chemical Cleaning: 2 – 10
  • Feed Flow Rate per Vessel: 50 L/min. (13 gpm)
  • Brine Flow Rate per Vessel: 10 L/min. (2.6 gpm)
  • Brine/Permeate Flow Ratio: 6 (Ratio at last element, reducible if fouling/scaling possibility is low.)

Mechanical / hydraulic

  • Dimensions: Length 1016 mm. All dimensions are shown in millimeters.
  • Flow direction: F = Feed Water, B = Concentrated Brine.
  • Pressure Drop (per Element): 0.10 MPa (14 psi)
  • Pressure Drop (per Vessel): 0.20 MPa (29 psi)
  • Elements must be cleaned when pressure drop increases up to 1.5 times of initial value.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data for any project must match the official OEM PDF revision.