SU-720L

Engineering summary from PDF text extraction for SU-720L. Verify every value with the OEM datasheet.

Summary

Product identification

  • Model: SU-720L High flow RO element for brackish water
  • Membrane Type: Cross Linked Fully Aromatic Polyamide Composite
  • Element Configuration: Spiral Wound

Performance Specification

  • Salt Rejection:
    • Average: 99.0 %
    • Minimum: 98.0 % (for any single element)
  • Product Flow Rate:
    • Average: 22 m³/day (5800 gpd)
    • Minimum: 20 m³/day (5280 gpd) (for any single element)

Test Conditions (for performance specifications):

  • Feed Water Pressure: 1.0 MPa (150 psi)

  • Feed Water Temperature: 25 °C (77 °F)

  • Feed Water Concentration: 1500 mg/L as NaCl

  • Brine Flow Rate: 80 L/min (5.3 gpm)

  • Feed Water pH: 6.5

  • Note: Average values are for 100 elements after 1 hour of operation.

  • Membrane Surface Area: Nominal 28 m² (300 ft²)

    • Note: The membrane area stated is a nominal value and is not a guaranteed specification.

Operating limits

  • Feed Water Pressure:
    • Recommended: 1.5 MPa (220 psi)
    • Maximum: 4.1 MPa (600 psi)
  • Feed Water Temperature:
    • Recommended: 35 °C (95 °F)
    • Maximum: 45 °C (113 °F)
  • Feed Water Turbidity (SDI): 4 (measured according to ASTM D4189)
    • Note: High flux operation on feed water turbidity greater than 3 or 4 SDI generally results in frequent cleaning requirements.
  • Feed Water pH Range (Continuous Operation): 3 – 9
  • Feed Water pH Range (Chemical Cleaning): 2 – 10
  • Feed Flow Rate per Vessel: 200 L/min (53 gpm)
  • Brine Flow Rate per Vessel: 40 L/min (11 gpm)
  • Brine/Permeate Flow Ratio: 6 (at last element)
    • Note: This figure is reducible when there is less possibility of fouling and scaling.
  • Pressure Drop (per Element): 0.10 MPa (14 psi)
  • Pressure Drop (per Vessel): 0.20 MPa (29 psi)
    • Note: Element(s) must be cleaned when pressure drop increases up to 1.5 times of initial value.

Mechanical / hydraulic

  • Dimensions: All dimensions are shown in millimeters in the official PDF. The element has an overall length of 1016 mm. Diagrams indicate permeate and concentrated brine flow directions.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.